Page 104 of 130

4-17
E
To install the spark plug:
1. Clean the gasket surface.
2. Wipe any dirt from the threads of the
spark plug.
3. Screw the spark plug to the correct
torque.
NOTE:@ Wipe off any water on the spark plug or
inside the cap before installing the spark
plug cap. Push the spark plug cap down
until it is securely installed.
If a torque wrench is not available when
you are fitting a new spark plug, a good
estimate of the correct torque is 1/4 turn
to 1/2 turn past finger tight with the spark
plug wrench included in the tool kit. Have
the spark plug adjusted to the correct
torque with a torque wrench as soon as
possible.
@
WARNING@ Be careful not to damage the insulator
when removing or installing a spark plug.
A damaged insulator could allow sparks
to escape, which could lead to explosion
or fire.
@
4. Install the air filter element in the air filter
case, and then install the air filter case
cover. Spark plug tightening torque:
12.5 N·m (1.25 kgf·m, 9 ft·lb)
UF1B71.book Page 17 Tuesday, November 12, 2002 4:17 PM
Page 105 of 130
4-18
E
EJU01822
Lubrication points
To keep moving parts sliding or rotating
smoothly, coat them with water-resistant
grease.
Recommended water-resistant grease:
Yamaha Marine Grease/
Yamaha Grease A
Throttle cable (throttle body end)
Throttle cable (handlebar end)
Pull the throttle lever and remove the
seal1. Spray a rust inhibitor into the
outer cable. Refit the seal securely.
Steering cable (handlebar end)
UF1B71.book Page 18 Tuesday, November 12, 2002 4:17 PM
Page 108 of 130

4-21
E
EJU01971
Inspecting the battery
Check the level of the battery electrolyte
and make sure that the negative and posi-
tive leads are securely tightened.
WARNING@ Battery electrolyte is poisonous and
dangerous, causing severe burns, etc.
Electrolyte contains sulfuric acid.
Avoid contact with skin, eyes, or cloth-
ing.
Antidotes
External: Flush with water.
Internal: Drink large quantities of water
or milk. Follow with milk of magnesia,
beaten egg, or vegetable oil. Call phy-
sician immediately.
Eyes: Flush with water for 15 minutes
and get prompt medical attention.
Batteries produce explosive gases.
Keep sparks, flame, cigarettes, etc.,
well away. If using or charging the bat-
tery in an enclosed space, make sure
that it is well ventilated. Always shield
your eyes when working near batter-
ies.
KEEP OUT OF THE REACH OF CHIL-
DREN.
Be sure to connect the breather hose
to the battery. Fire or explosion could
result if the breather hose is damaged,
obstructed, or not connected properly.
@
CAUTION:@ Be careful not to place the battery on
its side.
Be sure to remove the battery from the
battery compartment when adding
electrolyte or charging the battery.
@
UF1B71.book Page 21 Tuesday, November 12, 2002 4:17 PM
Page 109 of 130

4-22
E
To replenish the battery:
1. Make sure that the electrolyte level is
between the upper 1 and lower 2 level
marks.
2. Refill the battery with distilled water if
necessary.
CAUTION:@ Normal tap water contains minerals that
are harmful to a battery. Use only dis-
tilled water for replenishing the battery.
@
To recharge the battery:
CAUTION:@ Do not attempt to charge a battery hast-
ily. Battery life could be shortened.
@
It is recommended to have a Yamaha
dealer charge the battery. If you charge the
battery yourself, carefully read the battery
charger instructions before charging and fol-
low the points below.
1. Remove all caps from the battery cell.
2. Add distilled water to the specified level if
the electrolyte level is low.
3. Set the charging rate to 1.9 ampere and
charge the battery slowly until the explo-
sive gases are discharged vigorously
from the battery cells.
To connect the battery terminals:
1. Make sure that the connections are cor-
rect when you install the battery in the
watercraft.
2. Make sure that the breather hose is
properly connected and that it is not
damaged or obstructed.
3. Make sure that the battery is securely
held in place.
1Positive (+): Red lead
2Negative (–): Black lead
3Breather hose
UF1B71.book Page 22 Tuesday, November 12, 2002 4:17 PM
Page 121 of 130

5-6
E
EJU01845
Connecting the jumper cables
1. Connect the positive (+) jumper cable 1
to the positive (+) terminals of both bat-
teries.
2. Connect one end of the negative (–)
jumper cable 2 to the negative (–) termi-
nal of the booster battery 3.
3. Connect the other end of the negative (–)
cable to an engine hanger 4.
CAUTION:@ Do not connect the end of the jumper
cable to the negative (–) terminal on the
watercraft battery! Be sure all connec-
tions are secure and correct before
attempting to start the engine. Any
wrong connection may damage the elec-
trical system.
4. Start the engine, and then disconnect
the cables by reversing the steps above.
CAUTION:@ Never push the start switch while the
engine is running.
Do not operate the start switch for
more than 5 seconds, otherwise the
battery will be discharged and the
engine will not start. Also, the starter
motor may be damaged. If the engine
does not start in 5 seconds, release
the start switch, wait 15 seconds, and
then try again.
UF1B71.book Page 6 Tuesday, November 12, 2002 4:17 PM
Page:
< prev 1-8 9-16 17-24