Page 83 of 801

YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15C ± 35C (59F ± 95F).
2) Make sure that high pressure valve (1) and low pressure valve
(2) of manifold gauge are firmly closed.
3) Connect high pressure charging hose (3) to high pressure ser-
vice valve (5) on vehicle, and connect low pressure charging
hose (4) to low pressure service valve (6) on vehicle.
4) Bleed the air in charging hoses (3), (4) by loosening their respec-
tive nuts on manifold gauge, utilizing the refrigerant pressure.
When a hiss is heard, immediately tighten nut.
CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
5) Warm up engine to normal operating temperature (engine cool-
ant temperature at 80 ± 90C (176 ± 194F)) and keep it at spe-
cified idle speed. (Radiator cooling fan should not be working
when checking pressure and temperature.)
6) Turn A / C switch ON, and set blower switch at ªHIº (4th position),
temperature control knob at ªCOOLº, air outlet control knob at
ªFACEº, fresh / circulation control knob at ªCIRCULATIONº.
(Confirm that A / C compressor and condenser fan are working.)
7) Keep all windows, doors and engine food open.
Ambient temperature
15 ± 35C (59F ± 95F)
Engine rpmKeep to 1,500 rpm.
Blower motor switchMax. (4th position)
Temperature controlMax. cool
Air outlet controlFace
Vehicle doorsAll open
Air inlet door positionRecirculation
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1) inserted
into center duct air outlet and another one set near evaporator
air inlet, read temperature indicated on each thermometer.
Page 89 of 801
YH4
GRAND
VITARA
Fig. A
Fig. B
Fig. C
C51-3-6 For G16
and J20 engines
C51-3-25 For
H25 engine
1B-18 AIR CONDITIONING (OPTIONAL)
INSPECTION OF A / C CONTROLLER AND ITS
CIRCUITS
CAUTION:
A / C controller and ECM cannot be checked by itself.
It is strictly prohibited to connect voltmeter or ohmmeter to
A / C controller and ECM with couplers disconnected from it.
A / C controller (1) and its circuits can be checked at A / C controller
wiring couplers by measuring voltage.
Voltage Check
1) Remove A / C controller (1) from vehicle (refer to ªA / C CON-
TROLLER REMOVALº in this section).
2) Remove ECM (2) from vehicle.
3) Connect A / C controller couplers to A / C controller and connect
ECM couplers to ECM.
4) Check each terminal voltage with couplers connected by refer-
ing to the A / C CONTROLLER VOLTAGE VALUES TABLE the
later.
Page 90 of 801
YH4
GRAND
VITARA
SYSTEM CIRCUIT
A. To heater fuse
B. To rear defogger fuse
C. To ignition / meter fuse
D. To A / C fuse
E. Only LH vehicle1. Blower motor relay
2. Blower motor
3. Blower motor switch
4. A / C switch
5. Deflloster position switch
6. Deflloster / foot position switch7. Dual pressure (refrigerant
pressure) switch
8. A / C thermistor (evaporator
temperature sensor)
9. Compressor relay
10. Compressor11. Condenser fan motor relay
12. Condenser fan motor
13. A / C controller
14. ECM
15. Compressor thermal switch
(only IWATA production vehicle)
TERMINAL ARRANGEMENT OF A / C CONTROLLER
TERMINAL ARRANGEMENT OF ECM FOR G16, J20 ENGINE
TERMINAL ARRANGEMENT OF ECM FOR H25 ENGINE
H25 engine
E61-27
G16, J20
engines
E61-8
H25 engine
E61-28
G16, J20
engines
E61-17
1919
19H25 engine
E61-5
G16, J20
engines
E61-22
AIR CONDITIONING (OPTIONAL) 1B-19
Page 91 of 801

YH4
GRAND
VITARA
1B-20 AIR CONDITIONING (OPTIONAL)
A / C CONTROLLER VOLTAGE VALUES TABLE
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC1-1B/WController main
power supplyGround to
engine (Fig. B)10 ± 14 voltsIgnition switch ON with engine
stopped
AC1-2B/YController main
groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
AC1 4Or
Refrigerant
p
ressure switchGround to
0 ± 1 volt
Refrigerant pressure within 225 kPa
(2.3 kg / cm
2, 32.7 psi) to 2548 kPa
(26 kg / cm
2, 370 psi) with engine
running
AC1-4Orpressure switch
inputengine (Fig. B)
10 ± 14 volts
Refrigerant pressure below
196 kPa (2.0 kg / cm
2, 28 psi) or
above 3140 kPa (32 kg / cm
2, 455 psi)
with engine running
AC1 7G/B
A / C switch input
and / or defroster
Ground to
8 ± 14 volts
Blower fan motor switch and A / C or
defroster position switch (see NOTE)
ON with engine running
AC1-7G/Bposition switch
input (see NOTE)engine (Fig. B)
0 ± 1.5 volts
Blower fan motor switch or A / C or
defroster position switch (see NOTE)
OFF with engine running
AC1 9Gr/W
Signal input from
ECM (A / C ON
Ground to10 ± 14 voltsApprove of A / C ON
AC1-9Gr/W(
permission
signal)engine (Fig. B)0 ± 1 voltA / C ON forbid
AC1-13Y/B
Signal output to
ECM (A / C ON
request signal)Ground to engine
(Fig. B)0 ± 1.5 volts
Blower fan motor switch and A / C or
defroster position switch (see NOTE)
ON with engine running at evaporator
thermistor temperature input more
than approx. 2.5C (less than 2.5 V
(5840 )) and refrigerant pressure
switch is ON
10 ± 14 voltsExcept the above-mentioned with
engine running
AC1-16P
Compressor
magnet clutch
relay outputGround to engine
(Fig. B)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch ON with
engine running at evaporator
thermistor temperature input more
than approx. 2.5C (less than 2.5 V
(5840 )), refrigerant pressure
switch ON and signal input from ECM
ON
10 ± 14 voltsExcept the above-mentioned with
engine running
Page 92 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-21
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC2-1L/YSensor groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
1.5 volts
(3150 )Evaporator thermistor temperature at
approx. 15C (59F) with engine
running
AC2-2W/B
Evaporator
thermistor
temperature
(evaporator temp.
sensor) input
Ground to engine
(Fig. B)
2.62 volts
(6.311 )
Evaporator thermistor temperature at
approx. 1C (34F) with engine
running
* If the temperature is less than
approx. 1C, in this case
compressor and condenser fan
should be stop (come back at more
than approx. 2.5C (less than
5840 , 2.5 V))
H25
engine
E61-27 /
G16 J20Gr/W
Signal output to
A / C controller
(A / C ON
Ground to engine
(Fig C)
10 ± 14 volts
Required A / C ON (terminal AC-A13)
at engine running with normal
condition (refer to ªINSPECTION OF
ECM AND ITS CIRCUITº in Section
6E)
G16, J20
engines
E61-8
(
permission
signal)(Fig. C)
0 ± 1 volt
Except the above-mentioned with
engine running
In this case compressor should be
stop
H25
engine
E61-28 /
Y/B
Signal input from
A / C controller
Ground to engine
0 ± 1.5 voltsRequire A / C ON
G16, J20
engines
E61-17Y/B(A / C ON request
signal)
g
(Fig. C)
10 ± 14 voltsTurn off the A / C
H25
engine
E61-5 /
G16, J20
engines
E61-22
Y/L
A / C condenser
cooling fan relay
outputGround to engine
(Fig. C)0 ± 1 volt
Blower fan motor switch and A / C or
defroster position switch (see
NOTE) ON with engine running at
evaporator thermistor temperature
input more than approx. 2.5C (less
than 2.5 V (5840 )), refrigerant
pressure switch ON and signal
input from ECM ON
Engine coolant temperature sensor
more than 113C (236F) with
engine running
10 ± 14 voltsExcept the above-mentioned with
engine running
NOTE:
Defroster position switch circuit is equipped with LH vehicle only.
Page 146 of 801
YH4
GRAND
VITARA
1. Power steering gear box
2. Power steering pump
3. P / S fluid reservoir
1. Power steering pump
2. Valve section
3. P / S fluid reservoir
4. Rack
5. Pinion
6. Cylinder
3B1-2 POWER STEERING (P / S) SYSTEM
GENERAL DESCRIPTION
POWER STEERING SYSTEM
The power steering (P / S) system in this vehicle reduces the driver's effort needed in turning the steering wheel
by utilizing the hydraulic pressure generated by the power steering (P / S) pump which is driven by the engine.
It is an integral type with the rack and pinion gears and the control valve unit, hydraulic pressure cylinder unit all
built in the steering gear box.
Page 148 of 801

YH4
GRAND
VITARA
1. Suction connector
2. O-ring
3. Pressure switch
4. Flow control valve
(Relief valve)
5. Spring
6. Plug
7. Pump cover
8. Cam ring
9. Vane
10. Rotor
11. Snap ring
12. Side plate
13. Pulley (pump shaft)
14. Oil seal
15. Pump body
16. Flow control valve Assembly
3B1-4 POWER STEERING (P / S) SYSTEM
POWER STEERING (P / S) PUMP
The power steering pump is a vane type and is driven by the V-ribbed belt from the crankshaft.
ModelVane type
Hydraulic
pressure
controlRelieved
pressure
6500 kPa (65 kg / cm2, 924 psi)
G16 Type engine . . . . . . . . . . . . . . . . . . . . . .
7000 kPa (70 kg / cm
2, 995 psi)
J20 Type engine . . . . . . . . . . . . . . . . . . . . . . .
7350 kPa (73.5 kg / cm
2, 1045 psi)
H25 Type engine . . . . . . . . . . . . . . . . . . . . . .
ControlFlow control valve
deviceRelief valve
Power steering
pressure switch
Switch turns on (closes) when the
pressure is higher than 2500 ± 3500 kPa
(25 ± 35 kg / cm
2, 356 ± 498 psi).
ECM uses this signal for idle speed control.
Capacity0.70 ± 0.75
(1.48 / 1.23 ± 1.58 / 1.32 US / Imp. pt)
Specified fluidDEXRONII, DEXRONIII A / T fluid
or equivalent
FLOW CONTROL VALVE
As the discharge rate of the P/S pump increases in proportion to the
pump revolution speed, a flow control valve is added to control it so
that the optimum amount of fluid for steering operation is supplied
according to the engine speed (driving condition).
Described below is its operation at different engine speed.
Page 361 of 801

YH4
GRAND
VITARA
5E1-20 ANTILOCK BRAKE SYSTEM (ABS) (OPTIONAL)
TABLE ± E EBD WARNING LAMP (BRAKE WARNING LAMP) CHECK-LAMP
COMES ªONº STEADY
CIRCUIT DESCRIPTION
EBD warning lamp (brake warning lamp) is controlled by parking brake switch, brake fluid level switch and ABS
control module / hydraulic unit assembly through lamp driver module in combination meter. Refer to ªTABLE-Aº for
circuit diagram.
STEP
ACTIONYESNO
11) Make sure that:
Parking brake is completely released.Go to step 2.Release parking
brake completely
Brake fluid level is upper than the minimum level.
Are the check results OK?and / or replenish
brake fluid.
2Does ªABSº warning lamp come on?Perform ªTABLE Bº
previously
outlined.Go to step 3.
31) Disconnect ABS hydraulic unit / control module
connector.
2) Check for proper connection to ABS hydraulic unit /
control module connector at terminals ªA26º.
3) If OK, apply chocks to wheels and select gear in neutral
position (P range for A / T).
4) Keep brake pedal depressed and start engine.
Release parking brake.
5) Connect terminal ªA26º of disconnected connector to
ground using service wire.
Does EBD warning lamp (brake warning lamp) turn off?Substitute a
known-good ABS
hydraulic unit /
control module
assembly and
recheck.ªBrº circuit open.
If wire and
connection are
OK, replace
combination
meter.