DTC P1143 HO2S1
EC-297
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC Confirmation ProcedureEBS00KAH
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
●Always perform at a temperature above −10°C (14°F).
●Before performing following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine and wait at least 10 seconds.
3. Turn ignition switch “ON” and select “HO2S1 (B1) P1143” of “HO2S1” in “DTC WORK SUPPORT” mode
with CONSULT-II.
4. Touch “START”.
5. Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm (M/T models) or
3,200 rpm (A/T models) after this step. If the engine speed
limit is exceeded, return to step 5.
6. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 50 seconds or more.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”. If “NG” is displayed, refer to EC-298, "
Diagnostic
Procedure" .
PBIB0546E
ENG SPEED 1,200 - 2,600 rpm (A/T models)
1,700 - 2,600 rpm (M/T models)
Vehicle speed 50 - 100 km/h (30 - 62 MPH)
B/FUEL SCHDL 3.0 - 5.2 msec
Selector lever Suitable position
PBIB0547E
SEC769C
DTC P1143 HO2S1
EC-299
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3.CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “SELF-LEARNING CONT” in “WORK SUPPORT” mode with CONSULT-II.
3. Clear the self-learning control coefficient by touching “CLEAR”.
4. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171 detected?
Is it difficult to start engine?
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch “OFF”.
3. Disconnect mass air flow sensor harness connector, and restart
and run engine for at least 5 seconds at idle speed.
4. Stop engine and reconnect mass air flow sensor harness con-
nector.
5. Make sure that DTC P0102 is displayed.
6. Erase the DTC memory. Refer to EC-48, "
HOW TO ERASE
EMISSION-RELATED DIAGNOSTIC INFORMATION" .
7. Make sure that DTC P0000 is displayed.
8. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171 detected?
Is it difficult to start engine?
Ye s o r N o
Yes >> Perform trouble diagnosis for DTC P0171. Refer to EC-186 .
No >> GO TO 4.
4.CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to EC-127, "
Component Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Replace heated oxygen sensor 1.
5.CHECK HEATED OXYGEN SENSOR 1
Refer to EC-300, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 1.
6.CHECK INTERMITTENT INCIDENT
Refer to EC-109, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
For circuit, refer to EC-151, "
Wiring Diagram" .
>>INSPECTION END
SEF215Z
MBIB0096E
DTC P1144 HO2S1
EC-303
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC Confirmation ProcedureEBS00KAP
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
If “DTC Confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
●Always perform at a temperature above −10°C (14°F).
●Before performing the following procedure, confirm that battery voltage is more than 11V at idle.
WITH CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Stop engine and wait at least 5 seconds.
3. Turn ignition switch “ON” and select “HO2S1 (B1) P1144” of “HO2S1” in “DTC WORK SUPPORT” mode
with CONSULT-II.
4. Touch “START”.
5. Start engine and let it idle for at least 3 minutes.
NOTE:
Never raise engine speed above 3,600 rpm (M/T models) or
3,200 rpm (A/T models) after this step. If the engine speed
limit is exceeded, return to step 5.
6. When the following conditions are met, “TESTING” will be dis-
played on the CONSULT-II screen. Maintain the conditions con-
tinuously until “TESTING” changes to “COMPLETED”. (It will
take approximately 50 seconds or more.)
If “TESTING” is not displayed after 5 minutes, retry from
step 2.
7. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”. If “NG” is displayed, refer to EC-304, "
Diagnostic
Procedure" .
PBIB0548E
ENG SPEED 1,200 - 2,600 rpm (A/T models)
1,700 - 2,600 rpm (M/T models)
Vehicle speed 50 - 100 km/h (30 - 62 MPH)
B/FUEL SCHDL 3.0 - 5.2 msec
Selector lever Suitable position
PBIB0549E
SEC772C
DTC P1144 HO2S1
EC-305
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
3.CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “SELF-LEARNING CONT” in “WORK SUPPORT” mode with CONSULT-II.
3. Clear the self-learning control coefficient by touching “CLEAR”.
4. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected?
Is it difficult to start engine?
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch “OFF”.
3. Disconnect mass air flow sensor harness connector, and restart
and run engine for at least 5 seconds at idle speed.
4. Stop engine and reconnect mass air flow sensor harness con-
nector.
5. Make sure that DTC P0102 is displayed.
6. Erase the DTC memory. Refer to EC-48, "
HOW TO ERASE
EMISSION-RELATED DIAGNOSTIC INFORMATION" .
7. Make sure that DTC P0000 is displayed.
8. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected?
Is it difficult to start engine?
Ye s o r N o
Yes >> Perform trouble diagnosis for DTC P0172. Refer to EC-193 .
No >> GO TO 4.
4.CHECK HO2S1 CONNECTOR FOR WATER
1. Turn ignition switch “OFF”.
2. Disconnect heated oxygen sensor 1 harness connector.
3. Check connectors for water.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness or connectors.
5.CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to EC-127, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace heated oxygen sensor 1.
SEF215Z
MBIB0096E
Water should not exist.
MBIB0091E
DTC P1146 HO2S2
EC-309
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
●If “DTC confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and
wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Never stop engine during this procedure. If the engine is stopped, retry procedure from step 2 in “Pro-
cedure for COND1”
WITH CONSULT-II
Procedure for COND1
For the best results, perform ″DTC WORK SUPPORT″ at a temperature of 0 to 30°C (32 to 86°F).
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch ″OFF″ and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
4. Let engine idle for one minute.
5. Select “HO2S2 (B1) P1146” of “HO2S2” in “DTC WORK SUPPORT” mode with CONSULT-II.
6. Touch START”.
7. Let it idle for at least 30 seconds.
8. Rev engine up to 2,000 rpm 2 or 3 times quickly under no load.
If “COMPLETED” appears on CONSULT-II screen, go to step 2 in Procedure for COND3”.
If “COMPLETED” does not appear on CONSULT-II screen, go to the following step.
9. When the following conditions are met, “TESTING” will be displayed at “COND1” on the CONSULT-II
screen. Maintain the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take
approximately 60 seconds.)
NOTE:
●If “TESTING” is not displayed after 5 minutes, retry from step 2 in “Procedure for COND1”.
●If “COMPLETED” already appears at “COND2” on CONSULT-II screen before “Procedure for
COND2” is conducted, it is unnecessary to conduct step 1 in “Procedure for COND2”.
Procedure for COND2
1. While driving, release accelerator pedal completed with “OD”
OFF (A/T models only) from the above condition [step 9] until
“INCOMPLETE” at “COND2” on CONSULT-II screen has turned
to “COMPLETED” (It will take approximately 4 seconds.)
NOTE:
If “COMPLETE” already appears at “COND3” on CONSULT-
II screen before “Procedure for COND3” is conducted, it is
unnecessary to conduct step 1 in “Procedure for COND3”.
ENG SPEED More than 1,000 rpm
B/FUEL SCHDL More than 1.0 msec
COOLANT TEMP/S 70 - 105°C
Selector lever Suitable position
PBIB0555E
PBIB0556E
EC-310
[QG (WITH EURO-OBD)]
DTC P1146 HO2S2
Procedure for COND3
1. Stop vehicle and let it idle until “INCOMPLETE” of “COND3” on
CONSULT-II screen has turned to “COMPLETED”. (It will take a
maximum of approximately 6 minutes.)
2. Make sure that “OK” is displayed after touching “SELF-DIAG
RESULTS”.
If “NG” is displayed, refer to EC-312, "
Diagnostic Procedure" .
If “CAN NOT BE DIAGNOSED” is displayed, perform the follow-
ing.
a. Turn ignition switch “OFF” and leave the vehicle in a cool place
(soak the vehicle).
b. Turn ignition switch “ON” and select “COOLANTEMP/S” in
“DATA MONITOR” mode with CONSULT-II
c. Start engine and warm it up while monitoring “COOLANTEMP/S” indication on CONSULT-II.
d. When ″COOLANTEMP/S″ indication reaches to 70°C (158°F), go to ″Procedure for COND 1″ step 3.
Overall Function CheckEBS00KAY
Use this procedure to check the overall function of the heated oxygen sensor 2 circuit. During this check, a
DTC might not be confirmed.
WITH GST
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch “OFF” and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
4. Let engine idle one minute.
5. Set voltmeter probes between ECM terminal 16 (HO2S2 signal) and engine ground.
6. Check the voltage when revving up to 4,000 rpm under no load
at least 10 times.
(Depress and release accelerator pedal as soon as possible.)
The voltage should be below 0.56V at least once during this
procedure.
If the voltage can be confirmed in step 6, step 7 is not nec-
essary.
7. Keep vehicle at idling for 10 minutes, then check the voltage. Or
check the voltage when coasting from 80 km/h (50 MPH) in “D”
position with “OD” OFF (A/T), 3rd gear position (M/T).
The voltage should be below 0.56V at least once during this
procedure.
8. If NG, go to EC-312, "
Diagnostic Procedure" .
SEC775C
MBIB0020E
DTC P1146 HO2S2
EC-313
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
2.CLEAR THE SELF-LEARNING DATA
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select “SELF-LEARNING CONT” in “WORK SUPPORT” mode
with CONSULT-II.
3. Clear the self-learning control coefficient by touching “CLEAR”.
4. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected?
Is it difficult to start engine?
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch “OFF”.
3. Disconnect mass air flow sensor harness connector, and restart
and run engine for at least 5 seconds at idle speed.
4. Stop engine and reconnect mass air flow sensor harness con-
nector.
5. Make sure that DTC P0102 is displayed.
6. Erase the DTC memory. Refer to EC-48, "
HOW TO ERASE
EMISSION-RELATED DIAGNOSTIC INFORMATION" .
7. Make sure that DTC P0000 is displayed.
8. Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0172 detected?
Is it difficult to start engine?
Ye s o r N o
Yes >> Perform trouble diagnosis for DTC P0172. Refer to EC-193 .
No >> GO TO 3.
3.CHECK HO2S2 GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch “OFF”.
2. Disconnect heated oxygen sensor 2 harness connector.
3. Disconnect ECM harness connector.
4. Check harness continuity between ECM terminal 74 and HO2S2
terminal 3.
Refer to Wiring Diagram.
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 4.
NG >> Repair open circuit or short to ground or short to power
in harness or connectors.
SEF215Z
MBIB0096E
Continuity should exist.
MBIB0256E
DTC P1147 HO2S2
EC-317
[QG (WITH EURO-OBD)]
C
D
E
F
G
H
I
J
K
L
MA
EC
DTC Confirmation ProcedureEBS00KB6
CAUTION:
Always drive vehicle at a safe speed.
NOTE:
●“COMPLETED” will appear on CONSULT-II screen when all tests “COND1”, “COND2” and
“COND3” are completed.
●If “DTC confirmation Procedure” has been previously conducted, always turn ignition switch “OFF” and
wait at least 10 seconds before conducting the next test.
TESTING CONDITION:
Never stop engine during this procedure. If the engine is stopped, retry procedure from step 2 in “Pro-
cedure for COND1”
WITH CONSULT-II
Procedure for COND1
For the best results, perform ″DTC WORK SUPPORT″ at a temperature of 0 to 30°C (32 to 86°F).
1. Start engine and warm it up to the normal operating temperature.
2. Turn ignition switch ″OFF″ and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least one minute under no
load.
4. Let engine idle for one minute.
5. Select “HO2S2 (B1) P1147” of “HO2S2” in “DTC WORK SUPPORT” mode with CONSULT-II.
6. Touch “START”.
7. Let it idle for at least 30 seconds.
8. Rev engine up to 2,000 rpm 2 or 3 times quickly under no load.
If “COMPLETED” appears on CONSULT-II screen, go to step 2 in “Procedure for COND3”.
If “COMPLETED” does not appear on CONSULT-II screen, go to the following step.
9. When the following conditions are met, “TESTING” will be displayed at COND1” on the CONSULT-II
screen. Maintain the conditions continuously until “TESTING” changes to “COMPLETED”. (It will take
approximately 60 seconds.)
NOTE:
●If “TESTING” is not displayed after 5 minutes, retry from step 2 in “Procedure for COND1”.
●If “COMPLETED” already appears at “COND2” on CONSULT-II screen before “Procedure for
COND2” is conducted, it is unnecessary to conduct step 1 in “Procedure for COND2”.
ENG SPEED More than 1,000 rpm
B/FUEL SCHDL More than 1.0 msec
COOLANT TEMP/S 70 - 105°C
Selector lever Suitable position
PBIB0557E