2003 JEEP GRAND CHEROKEE Heater controls

[x] Cancel search: Heater controls

Page 2090 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual A/C COMPRESSOR CLUTCH
DESCRIPTION
The compressor clutch assembly consists of a sta-
tionary electromagnetic coil, a hub bearing and pul-
ley assembly, and a clutch plate (Fig. 4). The
electromagnetic

Page 2091 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual STANDARD PROCEDURE - COMPRESSOR
CLUTCH BREAK-IN
After a new compressor clutch has been installed,
cycle the compressor clutch approximately twenty
times (five seconds on, then five seconds off). Durin

Page 2093 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual gap should be between 0.35 to 0.65 millimeter (0.014
to 0.026 inch). If the proper air gap is not obtained,
add or subtract shims as needed until the desired air
gap is obtained.
(9) Install the compr

Page 2094 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual open circuit to the fuse in the junction block as
required.
(5) The coil ground terminal cavity (85) is switched
to ground through the Powertrain Control Module
(PCM). There should be continuity betwe

Page 2095 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual Both the manual A/C Heater control panel and the
AZC control panel are serviced only as complete
units and cannot be repaired. If faulty or damaged,
the entire control panel unit must be replaced.
DIA

Page 2096 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual CURRENT FAULT CODES
System Faults 13 = Mode motor not
responding
14 = AI (Recirc) motor
not responding
15 = Left temperature
door not responding
16 = Right temperature
door not responding
17 = Mode do

Page 2097 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual HISTORICAL FAULT CODES
Input faults 33 = IR thermister circuit was open
34 = IR thermister circuit was shorted
35 = Fan pot was shorted
36 = Fan pot was open
37 = Mode pot was shorted
38 = Mode pot wa

Page 2098 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual (2)If there are no fault codes, the ª00º dis-
play value will remain in the VF window.Should
there be any codes, each will be displayed for one
second in ascending numerical sequence (note: no
effor