2003 JEEP GRAND CHEROKEE Coolant drain hose

[x] Cancel search: Coolant drain hose

Page 224 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual COOLING
TABLE OF CONTENTS
page page
COOLING
DESCRIPTION
DESCRIPTION - COOLING SYSTEM 4.7L
ENGINE..............................1
DESCRIPTION - COOLING SYSTEM
ROUTING 4.7L ENGINE..................1
DESC

Page 234 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual Carefully remove radiator pressure cap from filler
neck and check coolant level. Push down on cap to
disengage it from stop tabs. Wipe inside of filler neck
and examine lower inside sealing seat for n

Page 235 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual accessory drive belt (Refer to 7 - COOLING/ACCES-
SORY DRIVE/DRIVE BELTS - REMOVAL).
Add coolant to radiator to bring level to within 6.3
mm (1/4 in) of top of thermostat housing.
CAUTION: Avoid overh

Page 236 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual STANDARD PROCEDURE - DRAINING COOLING
SYSTEM - 4.0L ENGINE
WARNING: DO NOT REMOVE THE CYLINDER
BLOCK DRAIN PLUGS OR LOOSEN THE RADIATOR
DRAINCOCK WITH SYSTEM HOT AND UNDER
PRESSURE. SERIOUS BURNS FROM

Page 237 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual corrosion inhibitors called HOAT, for Hybrid Organic
Additive Technology) is recommended. This coolant
offers the best engine cooling without corrosion when
mixed with 50% distilled water to obtain to

Page 261 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual REMOVAL
REMOVALÐ4.0L ENGINE
WARNING: DO NOT LOOSEN THE RADIATOR
DRAINCOCK WITH THE SYSTEM HOT AND PRES-
SURIZED. SERIOUS BURNS FROM THE COOLANT
CAN OCCUR.
Do not waste reusable coolant. If the soluti

Page 262 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual (5) Install electrical connector to coolant tempera-
ture sensor.
(6) Be sure that the radiator draincock is tightly
closed. Fill the cooling system to the correct levelwith the required coolant mixtu

Page 265 of 2199

JEEP GRAND CHEROKEE 2003 WJ / 2.G Workshop Manual INSTALLATION
(1) Position relay to body and install 2 bolts.
Tighten bolts to 3 N´m (25 in. lbs.) torque.
(2) Connect electrical connector to relay.
(3) Connect vacuum hose to reservoir.
(4) Install
Page:   1-8 9-16 17-24 next >