HONDA CIVIC 2003 7.G Workshop Manual 7. Disconnectthe crankshaft position (CKP) sensor
connector {A) and variable valve timing control
{VTC) oil control solenoid valve connector (B).
Remove the VTC oil control solenoid valve (see
step 1

Page 114 of 1139

HONDA CIVIC 2003 7.G Workshop Manual 19.
20.
lnstall the variable valve timing control (VTC) oil
control solenoid valve (see step 1 on page 11127).
Connect the crankshaft position (CKP) sensor
connector {A) and VTC oil control solenoid

Page 118 of 1139

HONDA CIVIC 2003 7.G Workshop Manual Gylinder Head Removal
NOTE:. Use fender covers to avoid damaging painted
surfaces.
To avoid damage, unplug the wiring connectors
carefully whlle holding the connector portion.
To avoid damaging the cy

Page 136 of 1139

HONDA CIVIC 2003 7.G Workshop Manual 14. Installthe water bvpass hose.
15. Installthe air cleaner housing (see step 37 on page
5-15).
16. Installthe intake manifold (see page 9-5).
17. Installthe exhaust manifold (see page 9-7).
18. Ins

Page 138 of 1139

HONDA CIVIC 2003 7.G Workshop Manual 9.
10.
Install the four ignition coils (see page 4-18).
Check that all tubes, hoses, and connectors are
installed correctly.
lnstallthe intake manifold cover.11.
6x 1,0 mm12 N.m {1.2 kgf m.8.7 tbf.f

Page 182 of 1139

HONDA CIVIC 2003 7.G Workshop Manual Engine Lubrication
Oil Pump Overhaul (contdl
10. Remove the set clip from the oil pumpchain
tensioner.
11. Install the oil pan (see pageT-27).
8-16
\
I
(Oif Pressure Switch Replacement
1. Discon nect

Page 185 of 1139

HONDA CIVIC 2003 7.G Workshop Manual Removal:
1. Remove the intake manifold cover.
2.Remove the evaporative emission (EVAP) canister
hose (A), brake booster vacuum hose (B), and
vacuum hoses {C).
3. Disconnectthe intake airtemperature (

Page 186 of 1139

HONDA CIVIC 2003 7.G Workshop Manual Intake Manifold and Exhaust System
Intake Manifold Removal and Installation (contdl
5. Be prepared to catch and clean up spilled coolant.
Remove the water bypass hoses, then plug the
water bypass hos