3 - 16
INSP
ADJ
CHASSIS/BRAKE SYSTEM AIR BLEEDING
EC360000
CHASSIS
EC361012
BRAKE SYSTEM AIR BLEEDING
WARNING
Bleed the brake system if:
lThe system has been disassembled.
lA brake hose has been loosened or
removed.
lThe brake fluid is very low.
lThe brake operation is faulty.
A dangerous loss of braking performance
may occur if the brake system is not prop-
erly bleed.
1. Remove:
lReservoir cap
lDiaphragm
2. Bleed:
lBrake fluid
ÈFront
ÉRear
Air bleeding steps:
a. Add proper brake fluid to the reservoir.
b. Install the diaphragm. Be careful not to
spill any fluid or allow the reservoir to
overflow.
c. Connect the clear plastic tube 2 tightly to
the caliper bleed screw 1.
d. Place the other end of the tube into a con-
tainer.
e. Slowly apply the brake lever or pedal sev-
eral times.
f. Pull the lever in or push down on the
pedal. Hold the lever or pedal in position.
g. Loosen the bleed screw and allow the
lever or pedal to travel towards its limit.
h. Tighten the bleed screw when the lever or
pedal limit has been reached; then
release the lever or pedal.
T R..
Bleed screw:
6 Nm (0.6 m • kg, 4.3 ft • lb)
i. Repeat steps (e) to (h) until of the air bub-
bles have been removed from the system.
È
5PA30290
É
5PA30300
3 - 25
INSP
ADJFRONT FORK INTERNAL PRESSURE BLEEDING/FRONT
FORK REBOUND DAMPING FORCE ADJUSTMENT
2. Clean:
lDust seal a
lOil seal b
NOTE:
lClean the dust seal and oil seal after every
run.
lApply the lithium soap base grease on the
inner tube.
5PA30590
FRONT FORK INTERNAL PRESSURE
BLEEDING
NOTE:
If the front fork initial movement feels stiff dur-
ing a run, bleed the front fork internal pressure.
1. Elevate the front wheel by placing a suit-
able stand under the engine.
2. Remove the air bleed screw 1 and release
the internal pressure from the front fork.
3. Install:
lAir bleed screw
5PA30590
T R..1 Nm (0.1 m · kg, 0.7 ft · lb)
EC36H002
FRONT FORK REBOUND DAMPING FORCE
ADJUSTMENT
1. Adjust:
lRebound damping force
By turning the adjuster 1.
Stiffer
a
® Increase the rebound damp-
ing force. (Turn the adjuster
1 in.)
Softer
b
® Decrease the rebound damp-
ing force. (Turn the adjuster
1 out.)
Extent of adjustment
Maximum Minimum
Fully turned in
position20 clicks out (from
maximum position)
5PA30600