Page 58 of 801
YH4
GRAND
VITARA
1A-6 HEATER AND VENTILATION
6) Remove cooling unit (If equipped).
Refer to item COOLING UNIT (EVAPORATOR) REMOVAL in
Section 1B.
7) Disconnect fresh air control cable from blower motor case.
8) Remove blower motor unit (1) by removing its fastening nuts
(2).
9) Disconnect blower motor lead wire (2) at coupler from blower
unit (1).
10) Remove blower motor (3) by removing its mounting screws (4).
INSTALLATION
1) Reverse removal procedure for installation.
2) Connect fresh air control cable, refer to HEATER CONTROL
CABLES INSTALLATION.
3) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
Page 69 of 801

YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-17
1. Dash panel (engine room) 2. Nuts
REMOVAL
WARNING:
Failure to follow the following procedure and WARNING
may cause air bag deployment, personal injury, damage to
parts, or air bag being unable to deploy.
Never rest a steering column assembly on steering wheel
with air bag (inflator) module face down and column verti-
cal.
When handling the air bag (inflator) modules (driver and
passenger), be careful not to drop it or apply an impact to
it. If an excessive impact was applied (e.g., dropped from
a height of 91.4 cm (3 feet) or more, never attempt disas-
sembly or repair but replace it with a new one.
When grease, cleaning agent. Oil, water, etc. has got onto
air bag (inflator) modules (driver and passenger), wipe off
immediately with a dry cloth.
1) Disconnect negative (±) cable at battery.
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Drain engine coolant and disconnect heater hose (1) from
heater unit.
4) Remove instrument panel, refer to item INSTRUMENT PANEL
REMOVAL in Section 9.
5) Remove cooling unit (If equipped).
Refer to item EVAPORATOR (COOLING UNIT) REMOVAL in
Section 1B.
6) Disconnect rear duct (4) from heater unit.
7) Disconnect heater mode control actuator lead wire (1) at cou-
plers.
8) Remove A / C controller (2) (If equipped).
9) Remove SDM (3) (If equipped).
10) Remove heater unit.
Page 109 of 801
YH4
GRAND
VITARA
1
1. Ears1. Air flow
1B-38 AIR CONDITIONING (OPTIONAL)
CLEAN
Blow off dust by compressed air from air outlet side of the filter ele-
ment.
INSTALLATION
Reverse removal procedure for installation noting the followings:
Install filter into cooling unit directing arrow mark on its end face
to heater unit.
Enable air bag system after installation. Refer to ªENABLING AIR
BAG SYSTEMº in Section 10B.
Page 110 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-39
COOLING UNIT (EVAPORATOR)
REMOVAL
1) Disconnect negative (±) cable at battery.
2) Disable air bag system. Refer to ªDisabling Air Bag Systemº in
Section 10B.
3) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment.
The amount of compressor oil removed must be measured and
the same amount added to the system.
4) For G16 and J20 engine
Disconnect suction pipe (1), and liquid pipe (2) from evaporator
(cooling unit).
CAUTION:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and dust may not enter
cooling unit.
5) Remove blower motor unit. Refer to Section 1A ªHEATER AND
VENTILATIONº.
6) Disconnect thermistor wire coupler.
7) Remove cooling unit (evaporator).
DISASSEMBLY (FOR CAMI PRODUCTION VEHICLE)
1) Remove filter (2) from cooling unit (3) assembly by removing fil-
ter cover (1).
2) Remove screws (1) to separate evaporator upper and lower
cases from each other.
Page 112 of 801

YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-41
INSPECTION
1) Check evaporator fins for blockage. If found clogged, use com-
pressed air to clean the fins.
CAUTION:
Do not use water for cleaning of evaporator.
Be careful not to damage evaporator fins. If evaporator
fin is bent, straighten it by using a screwdriver or pair of
pliers. If any leakage is found from fitting or tube, repair
or replace evaporator.
2) Check inlet and outlet fittings for crack or scratch. Repair them
as required.
REASSEMBLY and INSTALLATION
1) Reverse removal and disassembly sequence to install cooling
unit, noting the following points.
Install uniformly the evaporator packing to dash panel hole for
expansion valve.
Adjust fresh air control cable, refer to ªHEATER CONTROL
LEVER ASSEMBLYº in Section 1A.
2) Enable air bag system. Refer to ªEnabling Air Bag Systemº in
Section 10B.
3) Evacuate and charge system. Refer to ªEVACUATINGº and
ªCHARGINGº in this section.
NOTE:
When the thermistor removed, it should be reinstalled in
original position.
If cooling unit or evaporator is replaced, pour 25 cc of refrig-
erating oil to compressor suction-side.
Page 113 of 801
YH4
GRAND
VITARA
3. Pipe clamp
1B-42 AIR CONDITIONING (OPTIONAL)
EXPANSION VALVE
INSPECTION
Refer to ªTroubleshooting Procedure Using Manifold Gauge Setº in
this section.
REMOVAL
1) Recover refrigerant by using recovery and recycling equipment.
Be sure to follow the instruction manual for the equipment. The
amount of compressor oil removed must be measured and the
same amount added to the system.
2) Remove front grill.
3) Disconnect suction pipe (1), and liquid pipe (2) from evaporator
(Cooling unit).
CAUTION:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and dust may not enter
cooling unit.
4) Disconnect suction pipe, and liquid pipe from suction hose (1)
and condenser outlet pipe (2).
5) Remove pipe clamp then remove suction pipe and liquid pipe.
6) Remove expansion valve (1).
INSTALLATION
1) Reverse removal sequence to install expansion valve.
2) Evacuate and charge system. Refer to ªEVACUATINGº and
ªCHARGINGº in this section.
Page 114 of 801
YH4
GRAND
VITARA
1. Evaporator thermistorTemperature
Resistance ( )
AIR CONDITIONING (OPTIONAL) 1B-43
A / C EVAPORATOR THERMISTOR
(EVAPORATOR TEMPERATURE SENSOR)
A thermistor is a temperature sensor to sense the temperature of
air discharged from evaporator. The electrical characteristic is
shown in the figure.
When temperature is lower than preset temperature, amplifier
makes magnet clutch turn off to prevent evaporator from frosting.
INSPECTION
Check resistance between A / C evaporator thermistor (1) termi-
nals.
If check results are as not specified, replace thermistor.
Sensor Temperature
Resistance
0C, 32F7.0 ± 7.7 k
25C, 77F2.1 ± 2.4 k
REMOVAL
Refer to ªCOOLING UNIT (EVAPORATOR)º in this section.
INSTALLATION
1) Reverse removal sequence to install thermistor.
2) Enable air bag system. Refer to ªENABLING AIR BAG SYS-
TEMº in Section 10B.
3) Evacuate and charge system. Refer to ªEVACUATINGº and
ªCHARGINGº in this section.