ON-BOARD DIAGNOSTIC
U–22–1
U
U–22H EA TER AND A I R C O NDI T ION ER SYST EMS
After Repair Procedure
1. Connect the SST (WDS or equivalent) to the
vehicle DLC-2 16-pin connector located as shown
in the figure.
2. Turn the ignition switch to the ON position.
3. Perform the DTCs reading procedure and record
any DTCs that are retrieved.
4. Clear the DTCs using the SST (WDS or
equivalent).
5. Verify that the customer’s concern has been
resolved.
Lockout Reset
Using the SST (WDS or equivalent)
1. Connect the SST (WDS or equivalent) to the
vehicle DLC-2 16-pin connector located as shown
in the figure.
2. Select “CLR_LOCKOUT” and “LOCKOUT”.
3. Turn “CLR_LOCKOUT” to ON using the
simulation function.
4. Verify that the “LOCKOUT” reading changes to
“Unlocked”.
Not using the SST (WDS or equivalent)
For factory equipped water heater unit
1. Turn the ignition switch to the OFF position.
2. Remove the HEATER 20 A fuse from the main
fuse block for more than 5 seconds.
3. Re-install the HEATER 20 A fuse.
For vehicles with a transmitter or timer
1. Turn the ignition switch to the OFF position.
2. Remove the power supply 20 A fuse from the
heater wiring harness for approx. 3 seconds.
3. Re-install the power supply 20 A fuse.
4. Press and hold down the ON switch of the
transmitter or timer for approx. 3 seconds.
5. Remove the power supply 20 A fuse from the
heater wiring harness for approx. 3 seconds.
6. Re-install the power supply 20 A fuse.
ON-BOARD DIAGNOSTIC
DLC-2
A6E3970W002
DLC-2
A6E3970W002
HEATER 20 A FUSE
MAIN FUSE
BLOCK
B6E0740TL02
WAIT FOR
APPROX. 3
SECONDS
OR
ON
ONWAIT FOR
APPROX. 3
SECONDS WAIT FOR
APPROX. 3
SECONDS
B6E0740TL03
U–22–2
ON-BOARD DIAGNOSTIC
PID/Data Monitor and Record Procedure
1. Connect SST (WDS or equivalent) to the vehicle
DLC-2 16-pin connector located as shown in the
figure.
2. Access and monitor PIDs by WDS or equivalent.
End Of SieDTC TABLEA6E857001038202
* : If a DTC not listed above is detected, there is a water heater malfunction, and the water heater must be
replaced.
End Of SiePID/DATA MONITOR AND RECORDA6E857001038209PID Monitoring Item Table
DLC-2
A6E3970W002
DTC Possible cause Page
B1317 Input voltage high (See U–22–3 DTC B1317)
B1318 Input voltage low (See U–23 DTC B1318)
B1342 Malfunction in water heater unit(See U–23 DTC B1342, B2463,
B2537, B2538, B2547)
B2449 Glow plug circuit short to ground (See U–24 DTC B2449, B2450)
B2450 Glow plug circuit open (See U–24 DTC B2449, B2450)
B2451 Fuel pump circuit short to ground (See U–24 DTC B2451, B2452)
B2452 Fuel pump circuit open (See U–24 DTC B2451, B2452)
B2453 Blower fan circuit short to ground (See U–25 DTC B2453, B2454)
B2454 Blower fan circuit open (See U–25 DTC B2453, B2454)
B2463 Overheat(See U–23 DTC B1342, B2463,
B2537, B2538, B2547)
B2537 Water heater system does not start(See U–23 DTC B1342, B2463,
B2537, B2538, B2547)
B2538 Unstable flame(See U–23 DTC B1342, B2463,
B2537, B2538, B2547)
B2547 Flame prior to operation(See U–23 DTC B1342, B2463,
B2537, B2538, B2547)
B2548 Water heater lockout mode (See U–25 DTC B2548)
PID Name
(Definition)Unit/
ConditionCondition/Specification
(Reference)ActionWater
Heater Unit
terminal
CCNTFFH
(Number of continuous
codes)—•DTC is detected: 1—255
•DTC is not detected: 0Perform inspection
using appropriate
DTC.—
ECT
(Engine coolant temperature)°C°F•ECT 20 °C {68 °F}: 20 °C {68 °F}
•ECT 60 °C {140 °F}: 60 °C {140 °F}——
VPWR_FFH
(Module supply voltage)V•Ignition switch ON: B+Inspect water heater
unit power supply
terminal.A
VPWR_LMT
(Low voltage threshold)V•Ignition switch ON: approx. 9.5 VInspect water heater
unit power supply
terminal.A
FAN
(Fan control)%•Blower fan is not operating: 0 %
•Blower fan is operating: 0—100 %——
GPD
(Glow plug duty cycle)%•Water heater unit is not operating: 0 %
•Water heater unit is operating: 0—100 %——
BLOWRMTR
(Blower motor)On/Off•Blower fan is not operating: Off
•Blower fan is operating: On——
ON-BOARD DIAGNOSTIC
U–22–3
U
Simulation Test Item Table
End Of SieDTC B1317A6E857001038203
Diagnostic procedure
End Of Sie
FP
(Fuel pump)On/Off•Water heater unit is not operating: Off
•Water heater unit is operating: On——
WATER_PMP
(Water pump)On/Off•Water heater unit is not operating: Off
•Water heater unit is operating: On——
GLOW PLUG
(Glow plugs)On/Off•Water heater unit is not operating: Off
•Water heater unit is operating: On——
COMB_FAN
(Combustion air fan)On/Off•Water heater unit is not operating: Off
•Water heater unit is operating: On——
LOCKOUT
(Heater lockout)Lock/
Unlock•Water heater unit is not operating: Lock
•Water heater unit is operating: Unlock——
FS
(Flame sensor)On/Off•Water heater unit is not operating: Off
•Water heater unit is operating: On——
HEATER
(Heater status)Inactive/
Active•Water heater unit is not operating:
Inactive
•Water heater unit is operating: Active——
HEATER_SW
(Heater activation switch)Inactive/
Active•Water heater unit is not operating:
Inactive
•Water heater unit is operating: Active—— PID Name
(Definition)Unit/
ConditionCondition/Specification
(Reference)ActionWater
Heater Unit
terminal
Item Definition OperationWater Heater
Unit terminal
CLR_LOCKOUT Heater lockout mode clearing command On/——
FUEL_PRIMEFuel pump priming command
(The fuel pump is activated for 5 seconds.)On/——
DTC B1317 Input voltage high
DETECTION
CONDITION•Voltage detected at water heater unit terminals A is more than 16 V.
POSSIBLE
CAUSE•Short to power circuit between the generator and PCM
•Generator malfunction
•Battery malfunction
STEP INSPECTION ACTION
1INSPECT BATTERY VOLTAGE
•Measure the battery voltage.
•Is the voltage less than 16 V?Yes Go to the next step.
No Inspect the charging system.
2INSPECT WATER HEATER UNIT
•Clear the DTC.
•Perform the KOEO Self Test. (See U–22 KOEO
Self Test/Combustion Test.)
•Is the same DTC present?Yes Replace the water heater unit.
(See U–15 WATER HEATER UNIT REMOVAL/
INSTALLATION)
No Go to the next step.
3VERIFY AFTER REPAIR PROCEDURE
•Perform the after repair procedure. (See U–22–1
After Repair Procedure.)
•Are any DTCs present?Yes Go to the applicable DTC troubleshooting.
No Troubleshooting completed.
A C E
B
D F WATER HEATER UNIT CONNECTOR
ON-BOARD DIAGNOSTIC
U–25
U
End Of Sie
DTC B2453, B2454A6E857001038208
Diagnostic procedure
End Of Sie
DTC B2548A6E857001038210
Diagnostic procedure
End Of Sie
4INSPECT WATER HEATER UNIT
•Clear the DTC.
•Perform the KOEO Self Test. (See U–22
KOEO Self Test/Combustion Test.)
•Is the same DTC present?Yes Replace the water heater unit.
(See U–15 WATER HEATER UNIT REMOVAL/
INSTALLATION)
No Go to the next step.
5VERIFY AFTER REPAIR PROCEDURE
•Perform after repair procedure. (See U–22–1
After Repair Procedure.)
•Are any DTCs present?Yes Go to the applicable DTC troubleshooting.
No Troubleshooting completed. STEP INSPECTION ACTION
DTCB2453 Blower fan circuit short to ground
B2454 Blower fan circuit open
DETECTION
CONDITION•CPU detects Malfunction in blower fan circuit
POSSIBLE
CAUSE•Water heater unit malfunction
ACTION
•Replace the water heater unit.
(See U–15 WATER HEATER UNIT REMOVAL/INSTALLATION)
DTC B2548 Water heater lockout mode
DETECTION
CONDITION•This DTC is stored if the water heater unit detects the same DTC three times and the water heater unit
then suspends system operation for safety reasons.
POSSIBLE
CAUSE•Water heater unit malfunction
•Fuel pump (water heater system) malfunction
•Generator malfunction
•Battery malfunction
•Open or short circuit in related harness
STEP INSPECTION ACTION
1INSPECT WATER HEATER UNIT
•Perform the lockout reset. (See U–22–1 Lockout
Reset.)
•Read DTCs using the SST (WDS or equivalent)
•Are any DTCs present?Yes Go to applicable DTC troubleshooting.
No Troubleshooting completed.
U–26
TROUBLESHOOTING
FOREWORDA6E858001038201•Confirm the symptom using the following troubleshooting index and carry out the appropriate action.
End Of Sie
TROUBLESHOOTING INDEXA6E858001038202
End Of Sie
TROUBLESHOOTING
No. TROUBLESHOOTING ITEM ACTION
1 Fuel odor•Inspect the water heater system in the vehicle fuel
system.
•Inspect the fuel line for leakage, kinks, or blockage.
•If normal, there is an internal water heater leak.
—Replace the water heater unit.
2 The heater does not achieve full load operation•Replace the water heater unit.
3 Continuous white smoke during combustion operation•Replace the water heater unit.
4 Loss of coolant (leakage). Heater develops smoke during
combustion operation; smell of exhaust fumes extremely
sweet•Inspect the coolant hose for leakage, kinks,
looseness, and loose hose clamps.
•If normal, there is an internal water heater leak.
—Replace the water heater unit.
5 Loss of fuel (leakage)•Inspect the water heater system integration in the
vehicle’s fuel system.
•Inspect the fuel line connections for leakage.
•If normal, there is an internal water heater leak.
—Replace the water heater unit.
6 The water heater unit does not communicate with the SST
(WDS or equivalent)•Refer to section T, ON-BOARD DIAGNOSTIC
[MULTIPLEX COMMUNICATION SYSTEM].
TD–4
TECHNICAL DATA
ENGINE ELECTRICAL SYSTEMA6E931001001205
*1: Back-up current is the constant flow of current present (for the audio unit, clock, PCM, etc.) when the engine
switch is off and with the key removed.
*
2: Must not be 0 A.
*3: Cold area
End Of Sie
CLUTCHA6E931001024201
End Of Sie
MANUAL TRANSAXLEA6E931001024202
ItemSpecification
Diesel engine
MZR-CD (RF Turbo)
BatteryElectrolyte gravity 1.27—1.29
Back-up current*
1(mA) Max.20
Type
95D31L, 115D31L
*3
Test load chart (A) Battery type95D31L (64) 250
115D31L (70) *3320
Slow-charge (A)Battery type
(5-hour rate)95D31L (64) 6.5—8.0
115D31L (70)
*37.0—8.5
Quick-charge
Battery type
(5-hour rate)95D31L (64) 40
(A/30 min)
115D31L (70)
*345
GeneratorStandard voltage (V)Ignition switch ON TerminalBB+
L Approx. 1
SB+
Idle [20°C {68°F}] TerminalB
14.1—14.7 L
S
Generated current*
2
(reference) (A) Engine speed (rpm)1,000 0—80
2,000 0—90
Starter No load testVoltage (V) 11
Current (A) Below 130
Item Specification
Clutch coverDiaphragm
spring fingersDepth mm {in} 0.6 {0.024}
Misalignment mm {in} 0.6 {0.024}
Maximum clearance of flatness of the
pressure platemm {in} 0.3 {0.012}
Flywheel Run out limit mm {in} 0.3 {0.012}
Item Specification
Manual transaxle typeA65M-R
Transaxle controlFloor-shift
Operation systemCable
Shift assistSynchromesh
Gear ratio1st 3.416
2nd 1.944
3rd 1.258
4th 0.902
5th 0.659
Reverse 3.252
Final gear ratio3.588
Transaxle oilGrade API service GL-4 or GL-5
Viscosity (All-season) SAE 75W-90
Capacity (approximate quantity)
2.30 {2.40, 2.00}
(L {US qt, Imp qt})
ST–2
SPECIAL TOOLS
ENGINEA6E941001001205
End Of Sie
LUBRICATION SYSTEMA6E941001001206
End Of Sie
COOLING SYSTEMA6E941001001207
End Of Sie
SPECIAL TOOLS
49 S120 710
Coupling flange
holder 49 G033 107A
Dust cover
installer49 S120 215B
Pulley puller
49 G011 106
Camshaft pulley
puller49 S013 1A1
Compression
gauge set49 B010 002
Oil seal installer
49 G012 0A0
Tappet adjust
wrench set49 G011 105
Crankshaft lock
tool49 U027 003
Oil seal installer
WDS 49 E017 5A0
Engine support
set
—
49 0187 280A
Oil pressure
gauge
——
49 9200 145
Radiator cap
tester adapter
set——
ST–4
SPECIAL TOOLS
End Of Sie
PROPELLER SHFTA6E941001024204
End Of Sie
FRONT AND REAR AXLEA6E941001018201
49 L019 013
Adapter49 E017 5A0
Engine Support
Set49 E011 1A0
Ring gear brake
set
WDS
——
49 0839 425C
Bearing puller
set49 H027 002
Bearing
Remover49 G030 370
Removing Plate
49 F015 002
Water seal
installer49 0636 145
Water pump
pulley boss
puller49 G030 797
Handle
49 H033 101
Bearing
remover49 U027 005
Bearing installer49 F401 331
Body
49 B034 201
Support block49 F401 335A
Attachment A
—
49 T028 3A0
Ball joint puller
set49 G033 102
Handle49 G033 105
Attachment