2002 JEEP GRAND CHEROKEE Ground strap

[x] Cancel search: Ground strap

Page 1316 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (32) Disconnect body ground strap at the right side
cowl.
NOTE: It will be necessary to support the transmis-
sion in order to remove the engine.
(33) Position a suitable jack under the transmis-
sion

Page 1317 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual ²Camshaft Position (CMP) Sensor
²Coil Over Plugs
(10) Install generator (Refer to 8 - ELECTRICAL/
CHARGING/GENERATOR - INSTALLATION).
(11) Install radiator (Refer to 7 - COOLING/EN-
GINE/RADIATOR -

Page 1380 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (6) Remove accessory drive belt (Refer to 7 -
COOLING/ACCESSORY DRIVE/DRIVE BELTS -
REMOVAL).
(7) Disconnect generator electrical connections.
(8) Unbolt the generator and move it away from
the intake

Page 1381 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (7) Connect throttle cable and speed control cable
to throttle body.
(8) Install fuel rail (Refer to 14 - FUEL SYSTEM/
FUEL DELIVERY/FUEL RAIL - INSTALLATION).
(9) Install ignition coil towers (Refer

Page 2104 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual REMOVAL
(1) Disconnect and isolate the battery negative
cable.
(2) Depress locking tab and unplug the wire har-
ness connector from the blower motor controller.
(3) Depress locking tab and unplug the

Page 2105 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (3) Check for continuity between each of the
blower motor switch input terminals of the resistor
and the resistor output terminal. In each case there
should be continuity. If OK, repair the wire harne

Page 2115 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (1) Disconnect and isolate the battery negative
cable.
(2) Pinch the connector retainer and unplug the
blower motor wire harness from the blower motor
(Fig. 2).
(3) Remove the three screws that secure

Page 2121 of 2199

JEEP GRAND CHEROKEE 2002 WJ / 2.G Workshop Manual (9) Remove the 10 screws that secure the two
housing halves to each other.
(10) Separate the top half of the HVAC housing
from the bottom half (Fig. 18).
Fig. 17 WIRE HARNESS ELECTRICAL
CONNECTOR(S)
1