HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
DTC Troubleshooting lcontd)
22. Measure the voltage between the No. 3 terminal of
the blower motor relay 4P socket and body ground.
BLOWER MOTOR RELAY 4P SOCKET
21
43
23.

Page 796 of 1139

HONDA CIVIC 2002 7.G Workshop Manual 3.
Recirculation Control Motor Circuit Troubleshooting
1. Check the No. 14(10A)fuse inthe under-dashfuse/
relay box.
ls the f use OK?
YES Go to step 2.
NO- Replace the fuse, and recheck.l
2. Disconne

Page 797 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Recirculation Control Motor Circuit Troubleshooting (contd!
10. Turn the ignition swirch OFF.
11. Check for continuity between the following
terminals of heater control p

Page 800 of 1139

HONDA CIVIC 2002 7.G Workshop Manual 9.
10.
Disconnect the condenser fan 2P connector,
Check for continuity between the No. 1 terminal of
the condenser fan relay 4P socket and the No. 2
terminal of the condenser fan 2P connector.
CONDENS

Page 803 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Compressor Clutch Circuit
Troubleshooting (contdl
16. Check for continuity between the No. lterminal of
the compressor clutch relav 4P socket and the No. l
terminal of th

Page 805 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Air Mix Control Motor Test
1. Disconnect the 5P connector from the air mix
control motor.
2. Connect battery powertothe No. l terminal ofthe
air mix control motor, and gro

Page 806 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Mode Control Motor Test
Disconnect the 10P connector from the mode
control motor.
Connect battery power to the No. 1 terminal of the
mode control motor, and ground the No. 2
terminal; the mode control

Page 807 of 1139

HONDA CIVIC 2002 7.G Workshop Manual Heating and Air Conditioning
Recirculation Control Motor Test
1. Disconnect the 5P connector from the recirculation
control motor.
Incorrectly applying power and ground to
the recirculation control mo