WITH CONSULT-IINBEC0239S011) Start engine and warm it up to normal operating temperature.
2) Turn ignition switch ªOFFº and wait at least 10 seconds.
3) Turn ignition switch ªONº.
4) Select ªDATA MONITORº mode with CONSULT-II.
5) Make sure that ªFUEL T/TEMP SEº is more than 0ÉC (32ÉF).
6) Start engine and wait at least 20 seconds.
7) If 1st trip DTC is detected, go to ªDiagnostic Procedureº,
EC-385.
WITH GSTNBEC0239S021) Start engine and warm it up to normal operating temperature.
2) Check that voltage between ECM terminal 92 (Fuel tank tem-
perature sensor signal) and ground is less than 4.2V.
3) Turn ignition switch ªOFFº and wait at least 10 seconds.
4) Start engine and wait at least 20 seconds.
5) Select ªMODE 7º with GST.
6) If 1st trip DTC is detected, go to ªDiagnostic Procedureº,
EC-385.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
DTC Confirmation Procedure (Cont'd)
EC-383
Page 919 of 2395
Wiring DiagramNBEC0240
MEC964C
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Wiring Diagram
EC-384
Page 920 of 2395
Diagnostic ProcedureNBEC0241
1 CHECK RUBBER TUBE
1. Turn ignition switch ªOFFº.
2. Check rubber tube connected to the EVAP control system pressure sensor for clogging, vent, kink, disconnection or
improper connection.
SEF495R
OK or NG
OK©GO TO 2.
NG©Reconnect, repair or replace.
2 RETIGHTEN GROUND SCREWS
Loosen and retighten engine ground screws.
SEF959Y
©GO TO 3.
3 CHECK CONNECTOR
1. Disconnect EVAP control system pressure sensor harness connector.
2. Check sensor harness connector for water.
Water should not exist.
OK or NG
OK©GO TO 4.
NG©Repair or replace harness connector.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Diagnostic Procedure
EC-385
Page 921 of 2395

4 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ªONº.
2. Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-II or tester.
SEF992Y
OK or NG
OK©GO TO 6.
NG©GO TO 5.
5 DETECT MALFUNCTIONING PART
Check the following.
IHarness connectors B101, B43
IHarness connectors B1, M2 and M94, F27
IHarness for open or short between EVAP control system pressure sensor and ECM
©Repair harness or connectors.
6 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Check harness continuity between EVAP control system pressure sensor terminal 1 and engine ground.
Refer to Wiring Diagram.
Continuity should exist.
3. Also check harness for short to power.
OK or NG
OK©GO TO 8.
NG©GO TO 7.
7 DETECT MALFUNCTIONING PART
Check the following.
IHarness connectors B101, B43
IHarness connectors B1, M2 and M94, F27
IHarness for open between EVAP control system pressure sensor and ECM
IHarness for open between EVAP control system pressure sensor and TCM (Transmission Control Module)
©Repair open circuit or short to power in harness or connectors.
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Diagnostic Procedure (Cont'd)
EC-386
Page 922 of 2395

8 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 84 and EVAP control system pressure sensor terminal 2.
Refer to Wiring Diagram.
Continuity should exist.
3. Also check harness for short to ground and short to power.
OK or NG
OK (With CONSULT-II)©GO TO 10.
OK (Without CONSULT-
II)©GO TO 11.
NG©GO TO 9.
9 DETECT MALFUNCTIONING PART
Check the following.
IHarness connectors B101, B43
IHarness connectors B1, M2 and M94, F27
IHarness for open or short between ECM and EVAP control system pressure sensor
©Repair open circuit or short to ground or short to power in harness or connectors.
10 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
1. Start engine.
2. Perform ªPURG VOL CONT/Vº in ªACTIVE TESTº mode with CONSULT-II. Check that engine speed varies according
to the valve opening.
SEF985Y
OK or NG
OK©GO TO 12.
NG©GO TO 11.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Diagnostic Procedure (Cont'd)
EC-387
Page 923 of 2395
11 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air passage continuity of EVAP canister purge volume control solenoid valve under the following conditions.
SEF986Y
SEF334X
Without CONSULT-II
Check air passage continuity of EVAP canister purge volume control solenoid valve under the following conditions.
SEF986Y
SEF335X
OK or NG
OK©GO TO 12.
NG©Replace EVAP canister purge volume control solenoid valve.
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Diagnostic Procedure (Cont'd)
EC-388
Page 924 of 2395
12 CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK©GO TO 13.
NG©Clean the rubber tube using an air blower.
13 CHECK EVAP CANISTER VENT CONTROL VALVE-I
1. Remove EVAP canister vent control valve from EVAP canister.
2. Check portionBof EVAP canister vent control valve for being rusted.
SEF337X
OK or NG
OK©GO TO 14.
NG©Replace EVAP canister vent control valve.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Diagnostic Procedure (Cont'd)
EC-389
Page 925 of 2395
14 CHECK EVAP CANISTER VENT CONTROL VALVE
With CONSULT-II
1. Perform ªVENT CONTROL/Vº in ªACTIVE TESTº mode.
2. Check air passage continuity and operation delay time under the following conditions.
SEF991Y
Without CONSULT-II
Check air passage continuity and operation delay time under the following conditions.
SEF339X
Make sure new O-ring is installed properly.
OK or NG
OK©GO TO 16.
NG©GO TO 15.
15 CHECK EVAP CANISTER VENT CONTROL VALVE-III
1. Clean the air passage (portionAtoB) of EVAP canister vent control valve using an air blower.
2. Perform Test No. 14 again.
OK or NG
OK©GO TO 16.
NG©Replace EVAP canister vent control valve.
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Diagnostic Procedure (Cont'd)
EC-390