2001 INFINITI QX4 Ac system

[x] Cancel search: Ac system

Page 918 of 2395

INFINITI QX4 2001  Factory Service Manual SEF194Y
SEF340X
WITH CONSULT-IINBEC0239S011) Start engine and warm it up to normal operating temperature.
2) Turn ignition switch ªOFFº and wait at least 10 seconds.
3) Turn ignition switch ªONº.

Page 919 of 2395

INFINITI QX4 2001  Factory Service Manual Wiring DiagramNBEC0240
MEC964C
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM PRESSURE
SENSOR
Wiring Diagram
EC-384

Page 920 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0241
1 CHECK RUBBER TUBE
1. Turn ignition switch ªOFFº.
2. Check rubber tube connected to the EVAP control system pressure sensor for clogging, vent, kink, disconnection or
i

Page 921 of 2395

INFINITI QX4 2001  Factory Service Manual 4 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
1. Turn ignition switch ªONº.
2. Check voltage between EVAP control system pressure sensor terminal 3 and ground with CONSULT-II or t

Page 922 of 2395

INFINITI QX4 2001  Factory Service Manual 8 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND
SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 84 and EVAP control system pre

Page 923 of 2395

INFINITI QX4 2001  Factory Service Manual 11 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
With CONSULT-II
Check air passage continuity of EVAP canister purge volume control solenoid valve under the following conditions.
SEF986Y
SEF

Page 924 of 2395

INFINITI QX4 2001  Factory Service Manual 12 CHECK RUBBER TUBE FOR CLOGGING
1. Disconnect rubber tube connected to EVAP canister vent control valve.
2. Check the rubber tube for clogging.
OK or NG
OK©GO TO 13.
NG©Clean the rubber tube using

Page 925 of 2395

INFINITI QX4 2001  Factory Service Manual 14 CHECK EVAP CANISTER VENT CONTROL VALVE
With CONSULT-II
1. Perform ªVENT CONTROL/Vº in ªACTIVE TESTº mode.
2. Check air passage continuity and operation delay time under the following conditions