Page 743 of 2395

5 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 8.
NG©GO TO 7.
DTC P0131, P0151 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(LEAN SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-208
Page 744 of 2395

6 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 63 (HO2S1 bank 1 right signal) or 62 (HO2S1 bank 2 left signal) and
engine ground.
3. Check the following with engine speed held at 2,000 rpm constant under no load.
SEF967XA
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 8.
NG©GO TO 7.
7 REPLACE FRONT HEATED OXYGEN SENSOR
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector color.
SEF505Y
CAUTION:
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool
J-43897-18 or J-43897-12 and approved anti-seize lubricant.
©Replace malfunctioning heated oxygen sensor 1 (front).
8 CHECK INTERMITTENT INCIDENT
Refer to ªTROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTº, EC-140.
For circuit, refer to ªDTC P0130 (RIGHT BANK 1), P0150 (LEFT BANK 2) HEATED OXYGEN SENSOR 1 (FRONT)
[HO2S1 (FRONT) (BANK 1)/(BANK 2)] (CIRCUIT)º, EC-192.
©INSPECTION END
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0131, P0151 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(LEAN SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-209
Page 750 of 2395
5 CHECK HEATED OXYGEN SENSOR 1 (FRONT) HEATER
Check resistance between HO2S1 terminals as follows.
SEF969Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK (With CONSULT-II)©GO TO 6.
OK (Without CONSULT-
II)©GO TO 7.
NG©GO TO 8.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-215
Page 751 of 2395

6 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 8.
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-216
Page 752 of 2395

7 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 63 (HO2S1 bank 1 right signal) or 62 (HO2S1 bank 2 left signal) and
engine ground.
3. Check the following with engine speed held at 2,000 rpm constant under no load.
SEF967XA
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 8.
8 REPLACE HEATED OXYGEN SENSOR 1 (FRONT)
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector color.
SEF505Y
CAUTION:
Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool
J-43897-18 or J-43897-12 and approved anti-seize lubricant.
©Replace malfunctioning heated oxygen sensor 1 (front).
9 CHECK INTERMITTENT INCIDENT
Refer to ªTROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTº, EC-140.
For circuit, refer to ªDTC P0130 (RIGHT BANK, -B1), P0150 (LEFT BANK, -B2) HEATED OXYGEN SENSOR 1 [HO2S1
(FRONT) (BANK 1)/(BANK 2)] (CIRCUIT)º, EC-192.
©INSPECTION END
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0132, P0152 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RICH SHIFT MONITORING)
Diagnostic Procedure (Cont'd)
EC-217
Page 762 of 2395

7 CHECK HO2S1 (FRONT) INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal and front HO2S terminal as follows.
Refer to Wiring Diagram.
MTBL0473
Continuity should exist.
3. Check harness continuity between ECM terminal or FRONT HO2S terminal and ground as follows.
Refer to Wiring Diagram.
MTBL0474
Continuity should not exist.
4. Also check harness for short to power.
OK or NG
OK©GO TO 8.
NG©Repair open circuit or short to ground or short to power in harness or connectors.
8 CHECK HEATED OXYGEN SENSOR 1 HEATER (FRONT)
Check resistance between HO2S1 (front) terminals as follows.
SEF969Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 9.
NG©GO TO 13.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-227
Page 764 of 2395

11 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Select ªMANU TRIGº and adjust ªTRIGGER POINTº to 100% in ªDATA MONITORº mode with CONSULT-II.
3. Select ªHO2S1 (B1)/(B2)º and ªHO2S1 MNTR (B1)/(B2)º.
4. Hold engine speed at 2,000 rpm under no load during the following steps.
5. Touch ªRECORDº on CONSULT-II screen.
SEF967Y
6. Check the following.
IªHO2S1 MNTR (B1)/(B2)º in ªDATA MONITORº mode changes from ªRICHº to ªLEANº to ªRICHº 5 times in 10 seconds.
5 times (cycles) are counted as shown below.
SEF647Y
IªHO2S1 (B1)/(B2)º voltage goes above 0.6V at least once.
IªHO2S1 (B1)/(B2)º voltage goes below 0.3V at least once.
IªHO2S1 (B1)/(B2)º voltage never exceeds 1.0V.
SEF648Y
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 14.
NG©GO TO 13.
GI
MA
EM
LC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-229
Page 765 of 2395
12 CHECK HEATED OXYGEN SENSOR 1 (FRONT)
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Set voltmeter probes between ECM terminal 63 (HO2S1 bank 1 right signal) or 62 (HO2S1 bank 2 left signal) and
engine ground.
3. Check the following with engine speed held at 2,000 rpm constant under no load.
SEF967XA
CAUTION:
Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a
hard surface such as a concrete floor; use a new one.
OK or NG
OK©GO TO 14.
NG©GO TO 13.
13 REPLACE HEATED OXYGEN SENSOR 1 (FRONT)
1. Turn ignition switch ªOFFº.
2. Check heated oxygen sensor 1 (front) harness protector color.
SEF505Y
©Replace malfunctioning heated oxygen sensor 1 (front).
14 CHECK INTERMITTENT INCIDENT
Refer to ªTROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENTº, EC-140.
©INSPECTION END
DTC P0133, P0153 HEATED OXYGEN SENSOR 1 (FRONT) (BANK 1)/(BANK 2)
(RESPONSE MONITORING)
Diagnostic Procedure (Cont'd)
EC-230