SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual CRANKING SYSTEM 6G-3
Condition Possible Cause Correction
Motor not running 
(No operating sound of 
magnetic switch)Shift lever switch is not in P or N, or not adjusted 
(A/T)Shift in P or N, or adjus

Page 676 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6G-4 CRANKING SYSTEM
PERFORMANCE TEST
PULL-IN TEST
Connect battery to magnetic switch as shown.
Check that plunger and pinion move outward.
If plunger and pinion don’t move, replace magnetic switch.

Page 677 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual CRANKING SYSTEM 6G-5
NO-LOAD PERFORMANCE TEST
Connect battery and ammeter to starter as shown.
Check that starter rotates smoothly and steadily with pinion mov-
ing out. Check that ammeter indicates s

Page 687 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual CHARGING SYSTEM 6H-7
UNDERCHARGED BATTERY
This condition, as evidenced by slow cranking or indicator clear
with red dot can be caused by one or more of the following condi-