SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6E1-14 ENGINE AND EMISSION CONTROL SYSTEM
For TYPE B (Refer to NOTE in page “ECM INPUT/OUTPUT CIRCUIT DIAGRAM” for applicable model.)
CONNEC-
TORTERMINAL WIRE COLOR CIRCUITCONNEC-
TORTERMINAL WIRE

Page 664 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6F1-2 IGNITION SYSTEM (ELECTRONIC IGNITION SYSTEM)
GENERAL DESCRIPTION
The ignition system is an electronic (distributorless) ignition system. Its consists of the parts as described below
and has an e

Page 665 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual IGNITION SYSTEM (ELECTRONIC IGNITION SYSTEM 6F1-3
SYSTEM WIRING DIAGRAM
DIAGNOSIS
1. Ignition switch 7. No.1 spark plug
2. Main relay 8. No.2 spark plug
3. Ignition coil assembly for No.1 and No.4 spa

Page 666 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6F1-4 IGNITION SYSTEM (ELECTRONIC IGNITION SYSTEM)
IGNITION SYSTEM DIAGNOSTIC FLOW TABLE
Step Action Yes No
1Was “ENGINE DIAG. FLOW TABLE” in Section 6 per-
formed?Go to Step 2. Go to “ENGINE DI

Page 667 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual IGNITION SYSTEM (ELECTRONIC IGNITION SYSTEM 6F1-5
ON-VEHICLE SERVICE
IGNITION SPARK TEST
1) Disconnect all injector couplers (1) from injectors.
2) Remove spark plug and check it for condition and typ

Page 668 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6F1-6 IGNITION SYSTEM (ELECTRONIC IGNITION SYSTEM)
6) Install high-tension cords (2) to spark plugs and ignition coil
assemblies (1) while gripping each cap.
SPARK PLUGS
1) Remove air intake pipe and

Page 674 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual 6G-2 CRANKING SYSTEM
GENERAL DESCRIPTION
CRANKING CIRCUIT
DIAGNOSIS
DIAGNOSIS TABLE
Possible symptoms due to starting system trouble would be as follows: 
Starting motor does not run (or runs slowly)

Page 675 of 698

SUZUKI SWIFT 2000 1.G RG413 Service Workshop Manual CRANKING SYSTEM 6G-3
Condition Possible Cause Correction
Motor not running 
(No operating sound of 
magnetic switch)Shift lever switch is not in P or N, or not adjusted 
(A/T)Shift in P or N, or adjus