Maintenance and service11-11
–
CONTINUED –
12. Reinstall the c over und er the oil filter.
13. Pour the sp ec ified amount of eng ine oil throug h
the filler nec k.
Oil c ap ac ity: 4.2 US q t (4.0 liters, 3.5 Imp q t)
14. Start the eng ine and make sure that no oil leak s ap p ear around
the filter ’s rub b er seal.
15. Run the eng ine until it reac hes the normal op er ating temp erature.
Then stop the eng ine and wait a few minutes to allo w the oil d rain
b ac k. Chec k the oil level ag ain and if nec essary, a d d more eng ine oil.
Recommended grade and viscosity CAUTION
Use only engine oil with the recommended grade and viscosity.
Oil grade: API classification SJ or SH with the words “ENERGY
CONSERVING II ” (if you cannot obtain the oil with SJ
or SH grade, you may use SG grade oil.) or the new API certification mark (Starburst mark) dis-
played on the container.
New API Certification Mark (Starburst Mark)API Service label
1
2
3
1 Ind ic ates the oil q uality b y API d esig nations
2 Ind ic ates the SAE oil visc osity g rad e
3 Ind ic ates that the oil has fuel saving c ap ab ilities
11-16
HBB004FB
HBB007BB
4. Slowly p our the c oolant and fill to the rad iator filler nec k and to the
reserve tank ’s “FULL ” level mark. Do not p our the c oolant too q uic kly,
as this may lead to insuffic ient air b leed ing and t rap p ed air in the sys-
tem.
Coolant c ap ac ity: MT. 7.2 US q t (6.8 liters, 6.0 Imp q t)
AT. 7.1 US q t (6.7 liters, 5.9 Imp q t)
HG0115
Rubber gaskets
5. Put the rad iator c ap b ac k on and tig hten firmly. At this time, make
sure that the rub b er g asket in the rad iator c ap is c orrec tly in p lac e.
6. Start and run the eng ine for more than five minut es at 2,000 to
3,000 rp m.
7. Stop the eng ine and wait until the c oolant c ools d own (122 to
140 F [ 50 to 60 C] ). If there is any loss of c oolant, ad d c oolant t o the