 Resistance specifications  
Terminal on  
16-pin connector  Socket on VAG1598/20  
adapter  Specification  
Corrective action  
1   42  
 1.5    
Check connectors for:  - Repair open circuit a

Page 51 of 66

AUDI A8 2000 D2 / 1.G 01V Transmission Electrical Testing Workshop Manual 12   52  
 1.5    
  
13   22  
 1.5      
Pa
ge 51 of 66 Electrical testin
g
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.AT02.01.16

Page 52 of 66

AUDI A8 2000 D2 / 1.G 01V Transmission Electrical Testing Workshop Manual 01-305
 
Terminal on  
16-pin connector  Socket on VAG1598/20  
adapter  Specification  
Corrective action  
14   21  
 1.5    
- Repair open circuit according to current wiring diagram.
- Check conne

Page 53 of 66

AUDI A8 2000 D2 / 1.G 01V Transmission Electrical Testing Workshop Manual 01-306
      
Multi-function Transmission Range (TR) 
switch, checking
 
     
Note:  
     
Check the measuring value block for the TR-
switch display group number 004   page 01
-
203
 before checkin

Page 54 of 66

AUDI A8 2000 D2 / 1.G 01V Transmission Electrical Testing Workshop Manual 01-307
      
Multi-function Transmission Range (TR) 
switch -F125- (8-pin connector), testing  
     
1. Function test  
    
-  Release spring catch securing 8-pin connector -2- to connector on 
wir

Page 55 of 66

AUDI A8 2000 D2 / 1.G 01V Transmission Electrical Testing Workshop Manual 01-308
 Transmission with Multi-function Transmission Range (TR) switch -F125- with 8 - pin connector, checking  
Resistance measurement: switch multimeter to 2 M   measuring range  
Test 
step  Conne

Page 56 of 66

AUDI A8 2000 D2 / 1.G 01V Transmission Electrical Testing Workshop Manual - Selector lever in P, 
D, 3, and 2 Transmission 01V, Repair Group 38
   
1) Switch VAG1526 to highest resistance ( ) measuring range.  