Page 577 of 801
YH4
GRAND
VITARA
Operation
Terminal Front Door
Rear Door
Back Door (except Canvas Top Model)
LOCK
UNLOCK
LOCK
UNLOCK
LOCK
UNLOCK
8D-22 WINDOWS, MIRRORS, SECURITY AND LOCKS
POWER DOOR LOCK ACTUATOR
1) Disconnect power door lock actuator coupler.
2) Connect 12 V battery positive and negative terminals to the door
lock actuator terminals shown below and check operation.
If it does not operate as specified in table below, replace door
lock actuator.
UNLOCKLOCK
2
3
Page 578 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-23
POWER DOOR LOCK AND KEYLESS ENTRY SYSTEM (IF KEYLESS ENTRY IS
EQUIPPED)
SYSTEM INSPECTION
STEPACTIONYESNO
1Check power door lock operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 2.Go to Step 3.
2Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 4.Go to Step 6.
3Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 5.Go to Step 7.
4Check hazard warning lights operation referring to
its INSPECTION in this section.
Is this operation OK?This system is OK.Go to Step 10.
5Check door lock key and power door lock switch
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
6Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
7Check power door lock actuator circuit referring to
its INSPECTION in this section.
Is this circuit OK?Go to Step 8.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 8.
8Check power supply and grounding circuit
referring to its INSPECTION in this section.
Is this circuit OK?Go to Step 9.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 9.
91) Check door lock key and power door lock
switch circuit referring to its INSPECTION in
this section.
2) Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Are these circuits OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
Page 579 of 801

YH4
GRAND
VITARA
8D-24 WINDOWS, MIRRORS, SECURITY AND LOCKS
STEPACTIONYESNO
10Check that hazard warning lights flash with hazard
switch ON.
Is check result OK?Go to Step 11.Refer to ªTurn Signal
and Hazard Warning
Lightsº in DIAGNOSIS
and repair.
And go to Step 4.
11Check door knob switch and turn signal relay
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
POWER DOOR LOCK OPERATION
INSPECTION
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
KEYLESS ENTRY OPERATION
INSPECTION
1) With the IG switch OFF and all doors closed, push LOCK button
on transmitter. Check all power doors are locked.
2) Push UNLOCK button on transmitter. Check only driver side
power door is unlocked.
3) Push UNLOCK button on transmitter again within 5 seconds.
Check all power doors are unlocked.
But if any door is not opened within 30 seconds after power
door(s) unlocked, all power doors are locked again automatical-
ly.
If check result of Step 1) to Step 3) is satisfactory, this operation is
OK.
HAZARD WARNING LIGHTS OPERATION
INSPECTION
1) Check that hazard warning lights flash one time when power
doors are locked by pushing LOCK button on transmitter.
2) Check that hazard warning lights flash two times when power
door(s) is (are) unlocked by pushing UNLOCK button on trans-
mitter.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
Page 580 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-25
POWER DOOR LOCK ACTUATOR CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Use a 12 V battery to connect its (+) terminal to terminal E02-1,
and its (±) terminal to terminal E02-2 and E02-3. Check all power
doors are locked.
If check result is satisfactory, this circuit is OK.
POWER SUPPLY AND GROUNDING CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-7 and
groundAnytime10 ± 14 V
E02-14 and
groundAnytimeContinuity
If check result is satisfactory, this circuit is OK.
DOOR LOCK KEY AND POWER DOOR LOCK SWITCH
CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller.
3) Check for continuity between following terminals at each condi-
tion.
Terminals
ConditionSpecification
E02-8 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is LOCK positionContinuity
E02-9 and
When driver side door key
switch is OFF positionNo continuity
groundWhen driver side door key
switch is UNLOCK positionContinuity
If check result is satisfactory, this circuit is OK.
Page 581 of 801

YH4
GRAND
VITARA
8D-26 WINDOWS, MIRRORS, SECURITY AND LOCKS
IGNITION SWITCH AND DOOR SWITCH CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-4 and
When ignition switch is OFF
position0 V
groundWhen ignition switch is ON
position10 ± 14 V
E02 10 andWhen all doors are closedNo continuityE02-10 and
groundWhen any one door is
openedContinuity
If check result is satisfactory, this circuit is OK.
DOOR KNOB SWITCH AND TURN SIGNAL RELAY CIRCUIT
INSPECTION
1) Disconnect negative cable at battery.
2) Disconnect coupler of power door lock and keyless entry con-
troller, and connect negative cable at battery.
3) Check that the voltage and resistance between following termi-
nals are specifications.
Terminals
ConditionSpecification
E02-6 and
groundAnytime10 ± 14 V
E02-11 and
When driver side door lock
knob is pulled upContinuity
groundWhen driver side door lock
knob is pushed downNo continuity
If check result is satisfactory, this circuit is OK.
Page 582 of 801
YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-27
POWER DOOR LOCK SWITCH
INSPECTION
Refer to POWER DOOR LOCK SWITCH INSPECTION of POWER
DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT EQUIPPED)
in this section.
KEY CYLINDER SWITCH (DRIVER SIDE)
INSPECTION
Refer to KEY CYLINDER SWITCH (DRIVER SIDE) INSPECTION
of POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.
POWER DOOR LOCK ACTUATOR
INSPECTION
Refer to POWER DOOR LOCK ACTUATOR INSPECTION of
POWER DOOR LOCK SYSTEM (IF KEYLESS ENTRY IS NOT
EQUIPPED) in this section.
Page 583 of 801
YH4
GRAND
VITARA
8D-28 WINDOWS, MIRRORS, SECURITY AND LOCKS
TRANSMITTER
REPLACEMENT OF THE BATTERY
If the transmitter becomes unreliable, replace the battery.
As the battery power is consumed, the operation distance will be
shorter.
1) Put the edge of a coin or a flat blade screw driver in the slot (1)
of the transmitter and pry it open.
2) Replace the battery (lithium disc-type CR2032 or equivalent) so
its terminal faces the ª+º mark of the transmitter.
CAUTION:
Use care not to allow grease or dirt to be attached on the
printed circuit board and the battery.
3) Close the transmitter firmly.
4) Make sure the door locks can be operated with the transmitter.
NOTE:
To prevent theft, be sure to break the transmitter before
discarding it.
Dispose of the used battery properly according to appli-
cable rules or regulations. Do not dispose of lithium bat-
teries with ordinary household trash.
Page 584 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-29
CODE REGISTRATION PROCEDURE
1) Confirm that IG switch is OFF position and all doors are closed.
2) Open driver side door and then turn the IG switch to ON position
within 10 seconds.
3) Turn the IG switch to OFF position within 10 seconds after it is
turned to ON position.
4) Push and release the door switch to turn OFF and ON at three
times by hand within 20 seconds after the IG switch is turned to
OFF position.
5) Within 10 seconds after the door switch is turned to ON, turn the
IG switch to ON position and then OFF position.
6) Push and hold the LOCK and UNLOCK buttons on transmitter
at the same time within 20 seconds after IG switch is turned to
OFF position. Hold the buttons for at least 5 seconds. During this
time, the driver side door should lock and unlock once.
7) Push LOCK or UNLOCK buttons on transmitter within 5 seconds
after Step 6), and then confirm that driver side door is locked and
unlocked once.
NOTE:
Two transmitter codes can be registered.
When a new transmitter is registered, the oldest one will
be cleared.