1999 SUZUKI GRAND VITARA Evaporator

[x] Cancel search: Evaporator

Page 84 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-13
9) Check for each pressure of low side and high side if it is within
shaded range of graph.
If each gauge reading is out of specified pressure, corre

Page 85 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
1B-14 AIR CONDITIONING (OPTIONAL)
HIGH PRESSURE CAUGE LOW PRESSURE GAUGE THERMOMETER AT
CENTER DUCT
Insufficient
cooling of
condenser
PERFORMANCE DIAGNOSIS TABLE
TESTING RESULTSPOSSIB

Page 87 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
1. Blower motor main relay
2. Blower motor
3. Blower motor resistor
4. Blower motor switch
5. A / C controller
6. ECM
7. Heater mode control switch
8. Evaporator temperature sensor
9.

Page 88 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-17
1. Blower motor main relay
2. Blower motor
3. Blower motor resistor
4. Blower motor switch
5. A / C controller
6. ECM
7. Heater mode control switch
8

Page 90 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
SYSTEM CIRCUIT
A. To heater fuse
B. To rear defogger fuse
C. To ignition / meter fuse
D. To A / C fuse
E. Only LH vehicle1. Blower motor relay
2. Blower motor
3. Blower motor switch
4

Page 91 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
1B-20 AIR CONDITIONING (OPTIONAL)
A / C CONTROLLER VOLTAGE VALUES TABLE
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC1-1B/WController main
power supplyGround to
engine

Page 92 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-21
TerminalWireCircuitMeasurement
groundNormal valueCondition
AC2-1L/YSensor groundGround to body
(Fig. A)± 0.4 ± 0 voltEngine running
1.5 volts
(3150

Page 100 of 801

SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual YH4
GRAND
VITARA
1. Electric leak detector
AIR CONDITIONING (OPTIONAL) 1B-29
REMOVING MANIFOLD GAUGE SET
When A / C system has been charged with a specified amount of re-
frigerant, remove manifold ga
Page:   < prev 1-8 9-16 17-24 next >