YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-7
[INTERMITTENT TROUBLES]
There are cases where output of diagnostic output terminal
and / or malfunction indicator lamp indicate a diagnostic trouble
code representing a trouble which occurred only temporarily and
has gone. In such case, it may occur that good parts are replaced
unnecessarily. To prevent such accident, be sure to follow instruc-
tions given below when checking by using ªDiagnostic Flow
Tableº.
* When trouble can be identified, it is not an intermittent one:
Check coil antenna, ignition key, wires and each connection
and if they are all in good condition, substitute a known-good
ECM / PCM and recheck.
* When trouble can not be identified but output of diagnostic out-
put terminal and / or malfunction indicator lamp indicate a
trouble code:
Diagnose trouble by using that code No. and if ignition key, coil
antenna, wires and each connection are all in good condition,
turn OFF ignition switch and then ON.
Then check what malfunction indicator lamp and / or output of diag-
nostic output terminal indicate.
Only when they indicate trouble code again, substitute a known-
good ECM / PCM or Immobilizer Control Module and check again.
If they indicate not trouble code but normal code, it means that an
intermittent trouble did occur and has gone. In this case, check
wires and connections carefully again.
There are cases where output of diagnostic output terminal and/
or Suzuki scan tool indicates a diagnostic trouble code represent-
ing a trouble which occurred only temporarily and has gone. In
such case, it may occur that good parts are replaced unnecessar-
ily. To prevent such accident, be sure to follow instructions given
below when checking by using ªDiagnostic Flow Tableº.
* When trouble can be identified, it is not an intermittent one:
Check coil antenna, ignition key, wires and each connection
and if they are all in good condition, substitute a known-good
ECM / PCM and recheck.
* When trouble can not be identified but output of diagnostic out-
put terminal and/or Suzuki scan tool indicates a trouble code:
Diagnose trouble by using that code No. and if ignition key, coil
antenna, wires and each connection are all in good condition,
turn OFF ignition switch and then ON.
Then check what Suzuki scan tool and/or output of diagnostic out-
put terminal indicates.
Only when they indicate trouble code again, substitute a known-
good ECM / PCM or Immobilizer Control Module and check again.
If they indicate not trouble code but normal code, it means that an
intermittent trouble did occur and has gone. In this case, check
wires and connections carefully again.
YH4
GRAND
VITARA
8G-8 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
[NOTES ON SYSTEM CIRCUIT INSPECTION]
Refer to ªPrecautions for Electrical Circuit Serviceº and ªIntermit-
tents and Poor Connectionº in Section 0A.
[Precaution after replacing ECM / PCM or Immobilizer Control Mod-
ule]
When ECM / PCM was replaced, including when replaced be-
cause rechecking by using a known-good ECM / PCM was neces-
sary during trouble diagnosis, the ECM/Immobilizer Control Mod-
ule code must be registered in ECM / PCM and Immobilizer
Control Module by performing procedure described in ªProce-
dure after ECM / PCM Replacementº on p. 8G-27. If it is not regis-
tered, the engine would not start and accurate trouble diagnosis
would not be assured.
When Immobilizer Control Module was replaced, including when
replaced because rechecking by using a known-good Immobiliz-
er Control Module was necessary during trouble diagnosis, the
Transponder code and ECM/Immobilizer Control Module code
must be registered in Immobilizer Control Module and ECM/Im-
mobilizer Control Module code in ECM / PCM by performing pro-
cedure described in ªProcedure after Immobilizer Control Module
Replacementº on p. 8G-26. If they are not registered, the engine
would not start and accurate trouble diagnosis would not be as-
sured.
YH4
GRAND
VITARA
8G-12 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
EXAMPLE: When serial data link wire is defective (Code No.83)
ON
OFFMalfunction
indicator lamp
Code No.83 Code No.83 Code No.83
Time (sec.)
1. Data link connector (DLC)
3) After completing the check, turn ignition switch OFF and discon-
nect service wire from monitor coupler.
[Using SUZUKI scan tool]
1) Turn ignition switch OFF.
2) After setting cartridge to Suzuki scan tool, connect it to data link
connector (DLC) located on underside of instrument panel at
driver's seat side.
Special Tool
(A): 09931-76011 (Suzuki scan tool)
(B): Mass storage cartridge
(C): 09931-76030 (16 / 12 pin DLC adapter)
3) Turn ignition switch ON.
4) Read DTC according to instructions displayed on Suzuki scan
tool and print it or write it down. Refer to Suzuki scan tool opera-
tor's manual for further details.
NOTE:
When reading DTC stored in ECM / PCM using Suzuki scan
tool, select ªECMº from the applications menu and ªSU-
ZUKI modeº from the communication mode menu dis-
played on Suzuki scan tool.
If ECM / PCM detects a trouble in both electric fuel injec-
tion system and immobilizer control system, Suzuki scan
tool indicates trouble codes of both systems using Suzu-
ki mode of ECM application.
If communication between Suzuki scan tool and ECM / PCM is
not possible, check if Suzuki scan tool is communicable by con-
necting it to ECM / PCM in another vehicle. If communication is
possible in this case, Suzuki scan tool is in good condition. Then
check data link connector and serial data line (circuit) in the ve-
hicle with which communication was not possible.
5) After completing the check, turn ignition switch OFF and discon-
nect Suzuki scan tool from data link connector (DLC).
YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-13
DIAGNOSTIC TROUBLE CODE TABLE
Immobilizer Control Module side
DIAGNOSTIC TROUBLE CODEDIAGNOSTIC AREADIAGNOSISNO.VOLTMETER INDICATIONDIAGNOSTIC AREADIAGNOSIS
±Normal (No code)This code appears when none of the
other codes are identified.
11
Transponder code
31
Trans onder code
12Immobilizer Control Module
Diagnose trouble according to
13Coil antenna or ignition key with
built-in transponderDiagnose trouble according to
ªDIAGNOSTIC FLOW TABLEº
corresponding to each code No.
21ECM/Immobilizer Control Module code
corres onding to each code No.
22Ignition switch circuit
23Serial data link wire
ECM / PCM side
DTC
(indicated on
Suzuki
scan tool)DTC
(indicated
by MIL)Malfunction Indicator lamp
(MIL) flashing patternDIAGNOSTIC AREADIAGNOSIS
NO DTC12Normal
This code appears when it is
confirmed that none of other
trouble codes is set for immo-
bilizer control system or elec-
tronic fuel injection system.
P162381ECM/Immobilizer
P162084Control Module codeDiagnose trouble according to
ªDIAGNOSTIC FLOW
P162282ECM / PCMTABLEº corresponding to
each code No.
P162183Serial data link wire
YH4
GRAND
VITARA
1. Window regulator lubrication point 1. Regulator mounting bolts
2. Regulator motor mounting nuts
3. Hole
BODY SERVICE 9-5
FRONT DOOR WINDOW REGULATOR
REMOVAL
1) Remove door glass, referring to steps 1) to 9) of FRONT DOOR
GLASS REMOVAL in this section.
2) Disconnect power window motor lead wire at coupler and loosen
clamp.
3) Loosen regulator mounting bolts, nuts and take out regulator
through hole as shown in left figure.
INSPECTION
1) Check regulator sliding and rotating parts for greasing.
2) Check rollers for wear and damage.
3) Check wire for damage.
INSTALLATION
Reverse removal procedure to install window regulator noting the
following point.
Tighten bolts and nuts according to the order (a, b, c / 1, 2, 3, 4)
shown in left figure.
When installing glass, check that the top part of the glass contacts
the glass run evenly and that the glass moves up and down
smoothly.
If the glass is tilted with respect to the glass run, make a fine ad-
justment with the screws.
Install door window regulator handle (if equipped) so that it has
an angle as shown in figure when glass is fully closed.
YH4
GRAND
VITARA
9-14 BODY SERVICE
1. Door window
regulator attaching
nuts
2. Hole
1. Window regulator lubrication points
1. Door sealing
cover
2. Adhesive
REAR DOOR WINDOW REGULATOR
REMOVAL
1) Remove door glass, refer to steps 1) to 10) of REAR DOOR
GLASS REMOVAL in this section.
2) Disconnect power window motor lead wire at coupler and clamp.
3) Remove door window regulator attaching nuts (6 pcs.), and take
out regulator through hole as shown in left figure.
INSPECTION
1) Check regulator sliding and rotating parts for greasing.
2) Check rollers for wear and damage.
3) Check wire for damage.
INSTALLATION
Reverse removal sequence to install door window regulator noting
following points.
Tighten regulator base nuts according to the order (a, b, c) shown
in figure.
Adjust door window regulator according to following procedure.
a. Loosen three nuts, two screws and two bolts.
b. Raise window fully.
c. Tighten three regulator rail nuts according to the order (d, e,
f) shown in figure and two center sash bolts A.
d. Lower window.
e. Tighten two screws B to specified torque. Tighten front screw
first, then rear.
Tightening Torque for glass attaching screws
2.5 N
.m (0.25 kg-m, 1.8 lb-ft)
f. Check that the glass moves up and down smoothly and that
the top part of the glass contacts the glass run evenly.
Securely seal door sealing cover with adhesive.
Install door window regulator handle (if equipped) so that it has
an angle as shown when glass is fully closed.
YH4
GRAND
VITARA
9-36 BODY SERVICE
Sealer is applied to the specific joints of a vehicle dur-
ing production. The sealer is intended to prevent dust
from entering the vehicle and serves also as an anti-
corrosion barrier. The sealer is applied to the door and
hood hem areas and between panels. Correct and re-
seal the originally sealed joints if damaged. Reseal
the attaching joints of a new replacement panel and
reseal the hem area of a replacement door or hood.
Use a quality sealer to seal the flanged joints, overlap
joints and seams. The sealer must have flexible char-
acteristics and paintability after it's applied to repair
areas.
For the sealer to fill open joints, use caulking material.
Select a sealer in conformance with the place and
purpose of a specific use. Observe the manufactur-
er's label-stand instructions when using the sealer.
In many cases, repaired places require color painting.
When this is required, follow the ordinary techniques
specified for the finish preparation, color painting and
undercoating build-up.
Rust proof wax, a penetrative compound, is applied
to the metal-to-metal surfaces (door and side sill in-
sides) where it is difficult to use ordinary undercoating
material for coating. Therefore, when selecting the
rust proof wax, it may be the penetrative type.
During the undercoating (vinyl coating) application,
care should be taken that sealer is not applied to the
engine-related parts and shock absorber mounting or
rotating parts. Following the under coating, make
sure that body drain holes are kept open.
he sequence of the application steps of the anti-corro-
sion materials are as follows:
1) Clean and prepare the metal surface.
2) Apply primer.
3) Apply sealer (all joints sealed originally).
4) Apply color in areas where color is required such
as hem flanges, exposed joints and under body
components.
5) Apply anticorrosion compound (penetrative wax).
6) Apply undercoating (rust proof material).
PAINT AND COATINGS
ANTI-CORROSION TREATMENT
WARNING:
Standard shop practices, particularly eye
protection, should be followed during the per-
formance of the below-itemized operations to
avoid personal injury.
As rust proof treatment, steel sheets are given corro-
sion resistance on the interior and / or exterior.
These corrosion resistance steel sheet materials are
called one of two-side galvanized steel sheets.
It is for the sake of rust protection that these materials
are selected and given a variety of treatments as de-
scribed blow.
1) Steel sheets are treated with cathodic electroprim-
er which is excellent in corrosion resistance.
2) Rust proof wax coatings are applied to door and
side sill insides where moisture is liable to stay.
3) Vinyl coating is applied to body underside and
wheel housing inside.
4) Sealer is applied to door hem, engine compart-
ment steel sheet-to-steel sheet joint, and the like
portions to prevent water penetration and resulting
in rust occurrence.
In panel replacement or collision damage repair, leav-
ing the relevant area untreated as it is in any operation
which does disturb the above-mentioned rust proof
treatment will cause corrosion to that area. Therefore,
it is the essential function of any repair operation to
correctly recoat the related surfaces of the relevant
area.
All the metal panels are coated with metal condition-
ers and primer coating during vehicle production. Fol-
lowing the repair and / or replacement parts installa-
tion, every accessible bare metal surface should be
cleaned and coated with rust proof primer. Perform
this operation prior to the application of sealer and
rust proof wax coating.
YH4
GRAND
VITARA
When the welding or heating operation causes the
original galvanization or other anticorrosive materials
to be burnt, the interior and under-body panel sur-
faces must be cleaned.
Removal of residues of the burning should be carried
out carefully when the relevant place has boxtype
construction or has shape which limits the access to
the interior surfaces. In general, the following method
can be used satisfactorily for the removal of those res-
idues.Scrape the accessible places. If a standard putty knife
or scraper does not fit to the elevant place, consider
to use a more flexible scraper to a place narrowly en-
closed by sheet metals.
A jet of compressed air can remove most residues,
and is effective to limited areas.
However, this type of operation absolutely requires
eye protection.
BODY SERVICE 9-37
The metal service replacement parts (or assemblies)
are coated with electro-deposition primer.
For the proper adhesion of a paint, the following finish
process (refinish steps) becomes necessary.
1) Use wax or grease-removing solvent to clean the
part.
2) Use a wet or dry sand-paper (No. 400) to polish the
panel lightly. Do not polish it forcibly to produce any
scratch. Clean the part again.
3) If factory-applied primer coating is cut through to
the bare metal, apply metal conditioner to the bare
metal exposed to open air. As for method of use of
the metal conditioner, follow directions on the con-
tainer.
4) Apply primer-surfacer to the part completely dry
before starting sand-paper polishing. As for drying
time, follow directions advised on the primer-sur-
facer container.
5) Use a wet or dry sand-paper (No. 400) and water
to polish the panel lightly.
6) Wash the part again.
7) Apply color, coating to the part.
8) Different paints demand different drying methods.
Hence, follow directions advised on the pertinent
paint container.9) When lacquer coating (quick-drying paint coat-
ing) is applied, dry coated surface and polish it
with compound.
In the case of the melamine or acrylic coating,
compound polishing can be omitted after drying.
10) If the case of lacquer coating, wax should not be
applied to coated surface until the surface has
dried completely (for approx. two months).
Before replacing exterior parts or assemblies, check
paint conditions of all the covered or hidden interior
surfaces. If any rust scale is found at these places,
proceed as follows:
1) Use a proper wire brush, adhesive or liquid rust re-
moving agent to remove rust. As for the method of
use, follow directions advised for respecitve mate-
rials.
2) If necessary, wash parts with detergent, rinse, and
dry them.
3) Before installing exterior body parts, apply anticor-
rosive compound to all cleaner surfaces of exterior
body parts. Also, apply anticorrosive compound to
inner surfaces of exterior body parts to be
installed.
METAL REPLACEMENT PARTS FINISHING