Page 401 of 432
ELECTRICAL COMPONENTS
383
Checking battery fluid
There are 2 types of batteries: maintenance type and
non±maintenance type.
A non±maintenance battery has ºMAINTENANCE FREE
BATTERYº on its top. A maintenance type battery does not
have such indication.
Maintenance type battery
Check the fluid condition by the fluid level lines on the side
of the battery. Or if the battery has a hydrometer on its top,
you can also check the hydrometer.
Non±maintenance battery
Check the battery condition by the hydrometer on the top of
the battery.(a) Checking by the fluid level lines (Maintenance type
battery only)
Page 403 of 432
ELECTRICAL COMPONENTS
385
Check the battery condition by the hydrometer color.
Maintenance type battery
BLUE ± Good condition.
WHITE ± Charging necessary. Have the battery checked by
your Lexus dealer.
RED ± Add distilled water. (See ºAdding distilled waterº on
page 386.)
Non±maintenance type battery
BLUE ± Good condition.
WHITE ± Charging necessary. Have the battery checked by
your Lexus dealer.
RED ± Have the battery checked by your Lexus dealer.NOTICE
For non±maintenance battery:
Do not refill the battery with water.
Page 404 of 432
ELECTRICAL COMPONENTS
386
Adding distilled water
(Maintenance type battery only)
1. Remove the vent plugs.
2. Add distilled water to cells needing fluid.
If the side of your battery is covered, check the water level by
looking down directly above the cell as illustrated above.
3. Retighten the vent plugs securely.
NOTICE
Do not overfill the cells. Excess electrolyte could
squirt out of the battery during heavy charging,
causing corrosion or damage.
Use a cover on the battery for longer life.
BATTERY RECHARGING
PRECAUTIONS
During recharging, the battery is producing hydrogen
gas.
Therefore, before recharging:
1. Maintenance type batteries ± Remove the vent plugs.
2. If recharging with the battery installed on the vehicle, be
sure to disconnect the ground cable.
3. Make sure the power switch on the recharger is off when
connecting the charger cables to the battery and when
disconnecting them.
Page 405 of 432
ELECTRICAL COMPONENTS
387
CAUTION
Always charge the battery in an unconfined area. Do not
charge the battery in a garage or closed room where there
is not sufficient ventilation.
Non±maintenance batteries: Only do a slow charge (5 A or
less). Charging at a quicker rate is dangerous. The battery
may explode causing personal injuries.
Maintenance type batteries: Be sure to remove the vent