Page 246 of 1002
Downloaded from www.Manualslib.com manuals search engine
117-10
/Camshaft Timing Chain
NOTE-
The crankshaft hub center bolt is torqued to 410 Nm
(300 ft-lb).
- Install crankshaft damper puller (BMW special tool 11 8 21 0)
to
11 8 200. Use bolt to remove damper from crankshaft.
- Oil seal replacement:
4 Install cap (BMW special tool 11 2 383) on end of crankshaft.
Install seal guide (BMW special tool
11 2 385) over end of
crankshaft. Be sure to align groove with
lteyway on crank-
shaft (arrow).
4 Install oil seal puller (BMW special tool 11 2 380) and screw
in body of puller until it contacts seal. Tighten screw in center
of tool to draw seal out of cover.
Page 247 of 1002
![BMW 540i 1999 E39 Workshop Manual Downloaded from www.Manualslib.com manuals search engine
Camshaft Timing chain]
4 Coat new seal with oil and position in timing chain cover. Use
BMW special tool 11
3 280 and crankshaft center BMW 540i 1999 E39 Workshop Manual Downloaded from www.Manualslib.com manuals search engine
Camshaft Timing chain]
4 Coat new seal with oil and position in timing chain cover. Use
BMW special tool 11
3 280 and crankshaft center](/manual-img/1/2822/w960_2822-246.png)
Downloaded from www.Manualslib.com manuals search engine
Camshaft Timing chain]
4 Coat new seal with oil and position in timing chain cover. Use
BMW special tool 11
3 280 and crankshaft center bolt to draw
seal in flush with timing case cover.
- Align vibration damper assembly with keyway and tap into
place. Insert new center bolt with washer.
CA
UTIOG
Inspect woodruff key for damage before installing hub
assembly.
- Install crankshaft holding tool malting sure tool locks into
place in openings in damper assembly. While counterholding
cranltshaft, tighten crankshaft center bolt.
- Attach special tools 11 8 20011 1 8 190 to damper assembly.
Counterhold damper with 11 8 190 while tightening center
bolt.
Tightening
torque
Vibration damper hub to crankshaft 410 Nm (302 it-ib)
- Installation is reverse of removal noting the following:
Install drive belts. See 020 Maintenance.
Install cooling fan. See 170 Radiator and Cooling Sys-
tem.
Crankshaft oil seal, replacing
(M62 and M62 TU engines)
- Disconnect negative (-) cable from battery
CAUTIOG
Disconnecting the battery may erase fault code(s) storedin
control module memory. Check for fault codes using spe-
cial BMW diagnostic equipment.
* Prior to disconnecting the battery, read the battery dis-
connection cautions in
001 General cautions and
warnings.
- Remove splash guard from beneath engine
- Remove engine cooling fan assembly. See 170 Radiator
and Cooling System.
NOTE
-
Cooling fan nut (32 mm wrench) has left-hand threads.
- Remove drive belts. See 020 Maintenance.
NOTE-
Marlc direction of belt rotation if reusing belt.
Page 249 of 1002
Downloaded from www.Manualslib.com manuals search engine
117-13
Camshaft Timing chain1
< Install seal removing tool (BMW special tool 11 2 380) and
screw in body of puller until it makes firm contact with seal.
Tighten center screw in end of tool to draw out seal.
4 Coat new seal with oil, and use BMW special tool 11 1 220
and crankshaft center bolt to draw seal in flush with timing
case cover.
- Install damper hub and tighten new center bolt finger tight
4 Install angle gauge BMW special tool 11 3 460 as shown.
Page 251 of 1002

Downloaded from www.Manualslib.com manuals search engine
Camshaft Timina chain1
- Remove viscous clutch cooling fan. See 170 Radiator and
Cooling
System.
CA UTlOEIC
The radiator cooling fan nut (32mm wrench) has left- hand
threads.
.
< Remove engine trim covers:
Pry out plastic trim caps (arrows).
. Remove cover fasteners and covers.
4 Remove ignition coils:
0 Disconnect ignition coil electrical harness connectors
Remove
coil mounting fasteners and remove coils.
Remove spark plugs.
NOTE-
Make note of ignition coil ground strap locations.
Disconnect VANOS electrical harness connector
(A) and oil
line fitting
(B) from VANOS control unit.
NOTE-
Wrap the VANOS oil line fitting with a shop rag to absorb
leaking oil.
- Disconnect cranltcase breather by squeezing at arrows,
- Remove cylinder cover mounting fasteners and remove
cylinder head cover.
NOTE-
The cylinder head cover mounting bolt insulators and gas.
kets should be reinstalled in their original positions. Make
note of their arrangement during removal.
Page 252 of 1002
Downloaded from www.Manualslib.com manuals search engine
Camshaft Timing Chain -- - -1
Q Remove oil baffle cover
from intake
camshaft
Remove front engine lifting bracket fasteners (arrows
A) and
remove bracket.
- Remove cable duct clips (arrows B) from front of VANOS
control unit.
Rotate engine
clocltwise and set camshafts to Top Dead
Center (TDC). Cylinder
1 camshaft lobes will point towards
each other (arrows).
4 Remove plug from below starter and install crankshaft lock-
ing tool
(BMW special tool 11 2 300).
Page 258 of 1002

Downloaded from www.Manualslib.com manuals search engine
Camshaft Timing Chain
VANOS timing, checking and adjusting
(M52 engine)
NOTE-
* Special BMW service tools are required to remove and in-
stall the VANOS control unit. Read the procedure through
before starting the job.
If the camshafts are not properly timed, the pistons can
contact the valves.
- Disconnect negative (-) cable from battery.
CAUTIOG Disconnecting the battery may erase
faultcode(s) storedin
control module memory. Prior to disconnecting the battery,
checlc for fault codes using special BMW diagnostic equip-
ment.
Prior to disconnecting the battery, read the battery dis-
connection cautions given in
001 General Cautions
and Warnings.
- Remove viscous clutch cooling fan. See 170 Radiator and
Cooling
System.
CAUTIOG The radiator cooling fan nut
(32 mm wrench) has left-hand
threads.
4 Remove ignition coils:
Disconnect ignition coil electrical harness connectors.
Remove coil mounting fasteners and remove coils.
Remove
spark plugs.
NOTE-
Make note of ignition coil ground strap locations.
Page 259 of 1002
Downloaded from www.Manualslib.com manuals search engine
Camshaft Timing Chain
4 Disconnect VANOS electrical harness connector (A) and oil
line fitting
(B) from VANOS control unit.
NOTE-
Wrap the VANOS oil line fitting with a shop rag to absorb
leaking oil.
Disconnect cranltcase breather by squeezing at arrows.
- Remove cylinder cover mounting fasteners and remove
cylinder head cover.
NOTE-
The cylinder head cover mounting bolt insulators andgas-
lets should be reinstalled in their original positions. Make
note of their arrangement during removal.
4 Remove oil baffle cover from intake camshaft
Page 260 of 1002
Downloaded from www.Manualslib.com manuals search engine
1 17-24
I Camshaft Timing Chain
4 Remove banjo bolt from VANOS unit oil feed line and install
BMW special tool 11 3 450.
NOTE-
Oil will drain from oil feed line.
- Connect compressed air line (with pressure set to 2-8 bar or
30-1 10 psi.) to air fitting.
4 Measure gap (A) between secondary timing chain tensioner
and
intake camshaft sensor wheel. Make note of distance.
4 Connect cable test (BMW special tool 11 6 410) to VANOS
connector. Connect positive clip to positive battery terminal.
- Connect negative clip to battery negative terminal.
CAUTION-
Reversing terminals on special tool will damage diode on
VANOS solenoid valve.