Page 23 of 59
28-22
       Component location   Overview of component 
locations  Page 24
-5   
     
Test sequence  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select control module for engine electronics 
using "address word" 01   Page 01
-10
 . Engine 
must run at idle. 
Rapid data transfer 
HELP
Select function XX
    
When indicated on display  
-  Press buttons -0- and -8- to select "Read Measuring Value Block" and 
press -Q- button to confirm input. 
Read measurin
g value block 
Q
Enter display group number XXX
    
When indicated on display  
-  Press buttons -0-, -0- and -4- to select "display group number 004" and 
press -Q- button to confirm input. 
Read Measuring Value Block 4  
1 
2 
3 
4
    
Indicated on display  
-  Check specified value for Intake Air Temperature (IAT) sensor in 
display field 4: 
Pa
ge 23 of 59 I
gnition s
ystem, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.28.1 
     
        
        Page 32 of 59
28-31
       Component location   Overview of component 
locations  Page 24
-5   
     
Test requirement: 
     
Engine cold 
     
Test sequence  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select control module for engine electronics 
using "address word" 01   Page 01
-10
 . Engine 
must run at idle. 
Rapid data transfer 
HELP
Select function XX
    
When indicated on display  
-  Press buttons -0- and -8- to select "Read Measuring Value Block" and 
press -Q- button to confirm input. 
Read measurin
g value block 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -0- and -4- to select "display group number 004" and 
press -Q- button to confirm input. 
Read Measuring Value Block 4  
1 
2 
3 
4
    
Indicated on display  
-  Check indication in display field 3.
Pa
ge 32 of 59 I
gnition s
ystem, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.28.1 
     
        
        Page 55 of 59
28-51
      
Misfire recognition, checking
 
     
Special tools and equipment  
    
Test sequence  
VAS5051 with VAG5051/1
   orVAG1551 with VAG1551/3A
-  Connect VAS5051 tester or VAG1551 scan tool and select control 
module for engine electronics using "address word" 01   Page 01
-10
 . 
Engine must run at idle. 
Rapid data transfer 
HELP
Select function XX
    
When indicated on display  
-  Press buttons -0- and -8- to select "Read Measuring Value Block" and 
press -Q- button to confirm input. 
Read measurin
g value block 
Q
Enter displa
y group number XXX
    
When indicated on display  
-  Press buttons -0-, -1- and -4- to select "display group number 014" and 
press -Q- button to confirm input. 
Read Measuring Value Block 14  
1 
2 
3 
4
    
When indicated on display  
-  Check misfire recognition. 
Pa
ge 55 of 59 I
gnition s
ystem, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.28.1 
     
        
        Page 57 of 59
28-53
      
Check misfire recognition of the individual 
cylinders.  Read measuring value block 
Q
Enter display group number XXX
    
When indicated on display  
-  Press buttons -0-, -1- and -5- to select "display group number 015" 
and press -Q- button to confirm input. 
Read Measuring Value Block 15  
1 
2 
3 
4
    
When indicated on display  
-  Check misfire recognition in display fields 1 to 4.
  
Display fields  
  
1   2   3   4  
Display group 015: Misfire recognition of cylinders 1, 2 and 3  
Display  
xxx  
xxx  
xxx  
---  
Indicated  
Number of combustion 
misfires, cylinder 1  Number of combustion 
misfires, cylinder 2  Number of combustion 
misfires, cylinder 3  Misfire 
recognition  
Functional 
range    
  
  
activated  
locked  
Specified 
value  0  
0  
0  
activated  
Note  
If the specified value is exceeded: Evaluation   Page 28
-55
   
---  Pa
ge 57 of 59 I
gnition s
ystem, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.28.1 
     
        
        Page 58 of 59
28-54
      
- Press -C- button.Read measuring value block 
Q
Enter display group number XXX
    
When indicated on display  
-  Press buttons -0-, -1- and -6- to select "display group number 016" and 
press -Q- button to confirm input. 
Read Measuring Value Block 16  
1 
2 
3 
4
    
When indicated on display  
-  Check misfire recognition in display fields 1 and 4:
  
Display fields  
  
1   2   3   4  
Display group 016: Misfire recognition of cylinder 4  
Display  
xxx  
  
  
---  
Indicated  
Number of combustion misfires, cylinder 4  
  
  
Misfire recognition  
Functional range  
  
  
  
activated  
locked  
Specified value  
0  
  
  
activated  
Note  
If the specified value is exceeded: Evaluation   Page 28
-55
   
---  
Pa
ge 58 of 59 I
gnition s
ystem, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.28.1