20-169
Note:
If the leak cannot be located or repaired, contact
K-Line Customer Service - Technical Support.
Calibrate KLI9210 Tester
Determine vehicle leak threshold:
To m.y. 2000: leak threshold 0.040 in.
From m.y. 2001: leak threshold 0.020 in.
Test fuel cap - Attach test hose to appropriate preset port (black arrows).
- Turn control valve from "Hold" to "Test".
- Set flow meter flag (white arrow) at indicated value on flow meter.
- Turn control valve to "Hold"; remove test hose.
- Connect fuel cap tester to hose.
If no flow is indicated: - Screw fuel cap tightly to cap receiver (arrow).
- Turn control valve to "Test".
- Read flow meter on tester.