1999 AUDI A4 wiring

[x] Cancel search: wiring

Page 75 of 90

AUDI A4 1999 B5 / 1.G APB Engine Motronic Multiport Fuel Injection System Servising Workshop Manual 24-65
      
Voltage supply for Mass Air Flow (MAF) 
sensor, checking (Bosch MAF sensor)  
    
Note:  
Voltage is supplied to Mass Air Flow (MAF) sensor from Fuel Pump (FP) 
relay. 
If there is no ba

Page 77 of 90

AUDI A4 1999 B5 / 1.G APB Engine Motronic Multiport Fuel Injection System Servising Workshop Manual 24-67
      
Wire connections for Mass Air Flow (MAF) 
sensor, checking (Bosch MAF sensor)  
     
Note:  
     Signal wire is also checked during wire test. 
     
-  Connect VAG1598/31 test box at w

Page 82 of 90

AUDI A4 1999 B5 / 1.G APB Engine Motronic Multiport Fuel Injection System Servising Workshop Manual 24-71
 Reading Display Group 002  Display field 
4  
Possible cause of malfunction  
Corrective action  
Less than 3.0 
g/s   
Large quantity of un-metered air between intake manifold 
and Mass Air Fl

Page 83 of 90

AUDI A4 1999 B5 / 1.G APB Engine Motronic Multiport Fuel Injection System Servising Workshop Manual 24-72
      
Checking voltage supply to Mass Air Flow 
(MAF) sensor  
     
-  Disconnect harness connector from air mass 
meter. 
    
Note:  
The mass air flow sensor receives its voltage supply via

Page 84 of 90

AUDI A4 1999 B5 / 1.G APB Engine Motronic Multiport Fuel Injection System Servising Workshop Manual 24-73
 
    
Note:  
Socket 3 on the connector is the Ground (GND) connection from the 
engine control module. 
If the specification is not attained:  -  Connect hand-held multimeter (voltage measurem

Page 85 of 90

AUDI A4 1999 B5 / 1.G APB Engine Motronic Multiport Fuel Injection System Servising Workshop Manual 24-74
      
Checking wiring for mass air flow sensor  
     
Note:  
     The wiring test includes also testing the signal 
wire. 
     
-  Connect VAG1598/31 test box to wiring harness 
for engine c

Page 86 of 90

AUDI A4 1999 B5 / 1.G APB Engine Motronic Multiport Fuel Injection System Servising Workshop Manual 24-75
      
  
Resistance in wiring: max. 1.5      
-  Repair short circuit or open circuit if 
necessary. 
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations
Page:   < prev 1-8 9-16 17-24