Page 1261 of 1463

Application
Steering Wheel
Steering Gear Box
Oil Pump
Steering Column
Minmum Turning Radius
Oil
SECTION 6A
POWER STEERING SYSTEM
TABLE OF CONTENTS
Specifications . . . . . . . . . . . . . . . . . . . . . . . . 6A-1
General Specifications . . . . . . . . . . . . . . . . . . 6A-1
Fastener Tightening Specifications . . . . . . . . . 6A-1
Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . 6A-2
Hard Steering . . . . . . . . . . . . . . . . . . . . . . . . . 6A-2
Steering Pulls to One Side . . . . . . . . . . . . . . . 6A-2
Excessive Wheel Play . . . . . . . . . . . . . . . . . . . 6A-2
Poor Return of Steering Wheel . . . . . . . . . . . . 6A-2
Steering Wheel Shimmy . . . . . . . . . . . . . . . . . 6A-3
SPECIFICATIONS
GENERAL SPECIFICATIONS
Abnormal Noise From Steering System . . . . . 6A-3
Component Locator . . . . . . . . . . . . . . . . . . . 6A-4
Steering System . . . . . . . . . . . . . . . . . . . . . . . 6A-4
Maintenance and Repair . . . . . . . . . . . . . . . 6A-5
On-Vehicle Service . . . . . . . . . . . . . . . . . . . . . 6A-5
Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6A-5
Oil Pump Pressure Check . . . . . . . . . . . . . . . . 6A-6
Bleeding of Power Steering System . . . . . . . . 6A-6
Steering Gear Box . . . . . . . . . . . . . . . . . . . . . 6A-7
Number of Spoke
Outer Diameter
Type
Gear Ratio
Inner Steering Angle
Outer Steering Angle
Type
Maximum Pressure
Upper Tilting Angle
Lower Tilting Angle
Type
Capacity
Change Interval
Description
4
396 mm
Rack and Pinion
¥
33°37'
31°50'
Vane
75-82 kg/cm
2
4.646°
6.969°
5.25m
ATF DEXRON II
1 L
Every 24,000 km
FASTENER TIGHTENING SPECIFICATIONS
Application
Steering Shaft Bolt
Pressure Hose Bolt
Return Pipe Nut
Slotted Nut
Steering Gearbox BoltNlm
30 - 40
12 - 18
12 - 18
35 - 45
35 - 45
Page 1276 of 1463
7B/C-2 MANUAL & SEMIAUTO-HVAC
Application
Type
Capacity
Condenser Fan Motor OutputDescription
Parallel type (Multi Flow Condenser)
11,000 kcal/h
160W
CONDENSER
Application
Desiccant
Type
CapacityDescription
XH - 9 (30g)
Aluminum type
240cc
RECEIVER DRIER
Application
High
LowDescription
OFF: 27±2kgf / cm
2, DIFF : 6±2kgf / cm2
OFF : 1.8±0.2kgf / cm2, ON 1.9±0.3kgf/ cm2
DUAL PRESSURE SWITCH
SPECIFICATIONS
COOLING CAPACITY
Application
Type
Max. Capacity
Max. Blowing Capacity
Refrigerant
Refrigerant AmountDescription
Air mix type
4,500kcal/h
7.Om
3/min
R134a
650 - 75Og
Application
Model
Type
Output
Oil
Magnetic Clutch OutputDescription
FK- ll
Vane rotary type
140.5cc/rev
ZXL 200PG (PAG oil)
45W
COMPRESSOR
Page 1277 of 1463
MANUAL & SEMIAUTO-HVAC 7B/C-3
Application
Type
Expansion Valve
Resistance
Thermo AmpDescription
Tank laminated
Uniform external pressure type (1.5 RT)
4 stage (Coil resistance)
Sensor type OFF : 2±0.5°C, DIFF : 2±0.5°C
EVAPORATOR
Application
Heater Core Type
Heating Capacity
Heater Core Size (LxWxT)Description
2-ROW
4,600 kcal/h (AT 300 CMH)
219.5 x 151.8 x 52.0
HEATER UNIT
Application
Condenser Bolt
Condenser Fan Nut
Condenser Bolt
Receiver Drier Pipe Bolt
Receiver Drier Pipe Bolt (Condenser)
Pressure Pipe Bolt
Pressure Mounting BoltNlm
4-6
4-6
4-6
5-8
4-6
20-30
20-26
FASTENER TIGHTENING SPECIFICATIONS
Page 1279 of 1463

MANUAL & SEMIAUTO-HVAC 7B/C-5
Action
Clean oily plate using cleaning agent.
Charge battery or check for cause.
Check wire continuity
Check A/C switch and fan switch for continuity and ground.
DEFECTIVES IN FAN MOTOR CIRCUIT
Fan Motor Does Not Run
Checks
Blown fuse
Battery voltage is low
Faulty wiring
Faulty groundAction
Check for short and replace fuse.
Check battery voltage.
Check connectors’ connection.
Do not apply grease. This can cause voltage down.
Remove body painting and completely ground,
Tighten ground bolts and make sure body ground connection.
Checks
Blown resister temperature fuse
Air leakage in parts connection
Action
Replace resistor.
Check heater, cooling unit and blower for proper connection.
Fan Motor Runs in ‘4’position Only (‘3’, ‘2’, ‘1’ : Does Not Run)
Frosted Evaporator
DEFECTIVES IN COMPRESSOR CIRCUIT
Compressor Does Not Run
Checks
Faulty thermo ampAction
Frosted evaporator reduces cooling capacity.
Off compressor and maximize blowing capacity
Checks
Faulty high/low pressure
Faulty A/C relayAction
Check compressor magnet voltage supply.
A/C relay.
Checks
Oily clutch plate
Low voltage
Faulty electric connection or operation
Magnetic Clutch Slips /Idles
Checks
Clogged or blocked intake grilleAction
Clogged or blocked intake grille reduces blowing capacity.
Motor Runs With Poor Blowing
Checks
Excessive clearance between
Clutch plate and clutch coilAction
Adjust clutch clearance (0.2-0.6mm).
Magnetic Clutch Plays By Hand Only
Page:
< prev 1-8 9-16 17-24