1998 OPEL FRONTERA turn signal

[x] Cancel search: turn signal

Page 4900 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–243 ENGINE DRIVEABILITY AND EMISSIONS
DTC P1154 – HO2S Transition Time Ratio Bank 2 Sensor 1
StepNo Ye s Va l u e ( s ) Action
12Check for leaks at the exhaust manifold.
Are there leaks at the

Page 4905 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–248
ENGINE DRIVEABILITY AND EMISSIONS
Diagnostic Trouble Code (DTC) P1380 ABS Rough Road ABS System Fault
Circuit Description
The powertrain control module (PCM) monitors ABS fault
signal.  When

Page 4906 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–249 ENGINE DRIVEABILITY AND EMISSIONS
Diagnostic Trouble Code (DTC) P1404 EGR Closed Stuck
D06RW106
Circuit Description
The powertrain control module (PCM) monitors the EGR
valve  pintle  positio

Page 4992 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–335 ENGINE DRIVEABILITY AND EMISSIONS
General Description
General Description (PCM and
Sensors)
58X Reference PCM Input
The  powertrain  control  module  (PCM)  uses  this  signal
from  the  cran

Page 4996 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–339 ENGINE DRIVEABILITY AND EMISSIONS
0005
PCM Components
The PCM is designed to maintain exhaust emission levels
to  government  mandated  standards  while  providing
excellent  driveability  an

Page 4997 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–340
ENGINE DRIVEABILITY AND EMISSIONS
the  TP  sensor  is  low.    As  the  throttle  valve  opens,  the
output increases so that at wide open throttle (WOT), the
output voltage should be above 4

Page 4999 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–342
ENGINE DRIVEABILITY AND EMISSIONS
PCM to calculate  true  sequential multiport  fuel  injection
(SFI).  Loss of this signal will set a DTC P0341.  If the CMP
signal is lost while the engine i

Page 5000 of 6000

OPEL FRONTERA 1998  Workshop Manual 6E–343 ENGINE DRIVEABILITY AND EMISSIONS
constant measuring and adjusting of the air/fuel ratio, the
fuel injection system is called a “closed loop” system.
The PCM monitors signals from several