1998 NISSAN PATROL Check

[x] Cancel search: Check

Page 242 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual MULTI-REMOTE CONTROL UNIT INSPECTION TABLE
Terminal
No.Connections ConditionVoltage (V)
(approximate
values)
1 Driver side door switch Driver side doorOpened 0
Closed 12
2 Door switch (all doors)One o

Page 243 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual ID Code Entry Procedure
Note:
A maximum of four remote controllers can be entered. Any attempt to enter a remote controller will
erase all ID codes previously entered. Therefore, be sure to receive al

Page 247 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual CONSULT DIAGNOSTIC TEST MODE FUNCTION
CONSULT DIAGNOSTIC TEST
MODEDescription
C/U INITIALIZATION When replacing any of the following three components, C/U initialization is necessary.
[NATS ignition k

Page 248 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual Trouble Diagnoses
WORK FLOW
CHECK IN*Lighting-up mode of MIL (Malfunction Indicator Lamp)
For single malfunction of NATS: Blinking
For dual malfunctions of NATS and an engine-related part:
Stays ON
Fo

Page 249 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual SYMPTOM CHART
SYMPTOMDisplayed ``SELF-DIAG RESULTS
on CONSULT screen.DIAGNOSTIC PROCEDURE
(Reference page)SYSTEM
(Malfunctioning part or mode)
+MIL blinking
+Engine will startIMMUPROCEDURE 1
(EL-246

Page 251 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual DIAGNOSTIC PROCEDURE 3
Self-diagnostic results:
``CHAIN OF ECM-IMMU displayed on CONSULT screen
Con®rm SELF-DIAGNOSTIC
RESULTS ``CHAIN OF ECM-
IMMU displayed on CONSULT
screen.
OK
CHECK POWER SUP

Page 252 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual jA
CHECK COMMUNICATION LINE SHORT
CIRCUIT.
1. Disconnect ECM connector and IMMU
connector.
2. Check continuity between IMMU termi-
nalj
1and ground.
Continuity should not exist.
3. Turn ignition switc

Page 254 of 326

NISSAN PATROL 1998 Y61 / 5.G Electrical System Workshop Manual DIAGNOSTIC PROCEDURE 5
Self-diagnostic results:
``CHAIN OF IMMU-KEY displayed on CONSULT screen
Con®rm SELF-DIAGNOSTIC
RESULTS ``CHAIN OF IMMU-
KEY displayed on CONSULT
screen.
OK
CHECK NATS IGNI