between CKP sensor connector terminal No. 2 and PCM connector terminal
No. 43. If continuity does not exist, repair wiring harness as
necessary. If continuity exists, go to next step.
10) With ignition switch in ON position, check for voltage
between chassis ground and CKP sensor connector terminal No. 2. If 4.
8-5.2 volts do not exist, replace PCM. If voltage is to specification
and CKP sensor is suspected, go to next step.
11) Test is complete. Intermittent problem may exist. Road
test vehicle (if necessary) and attempt to duplicate conditions that
caused original complaint. Recheck for DTCs. If no DTCs are displayed,
go to INTERMITTENT DTCS .
DTC P0340: CAMSHAFT POSITION (CMP) SENSOR CIRCUIT FAILURE
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
NOTE: Procedures are provided by manufacturer for component
testing using an engine analyzer with oscilloscope
capability. Refer to manufacturer's operation manual for
instructions in use of oscilloscope.
1) If using scan tool, go to step 3). Disconnect CMP sensor
connector. Install Test Harness (MB991348) between CMP sensor and
connector. Using engine analyzer with oscilloscope capability, connect
special patterns probe to CMP sensor connector terminal No. 2. Go to
next step.
2) Start engine. Compare oscilloscope wave pattern with
known-good wave pattern. See Fig. 39. Verify wavelength (time)
decreases as engine RPM increases. If wave pattern fluctuates to left
or right, check for loose timing belt or an abnormality in sensor
pick-up disc. If a rectangular wave pattern is generated even when
engine is not started, substitute known-good CMP sensor. Repeat test.
If wave pattern is still abnormal, go to next step.
Fig. 39: Identifying Known-Good CMP Sensor Wave Pattern
Courtesy of Mitsubishi Motor Sales of America
3) On Montero, go to next step. On 3000GT, disconnect CMP
sensor connector. Turn ignition switch to ON position. Check voltage
between chassis ground and CMP sensor connector terminal No. 3. If
battery voltage does not exist, repair wiring harness as necessary. If
battery voltage exists, go to step 5).
4) Disconnect CMP sensor connector and MFI relay connector.
Using DVOM, check for continuity between CMP sensor connector terminal
No. 3 and MFI relay connector terminal No. 1. If continuity does not
exist, repair wiring harness as necessary. If continuity exists, go to
next step.
5) Check for continuity between chassis ground and CMP sensor
connector terminal No. 4 on 3000GT equipped with DOHC engine or 1 on
all other models. If continuity does not exist, repair wiring harness
as necessary. If continuity exists, on Montero, go to next step. On
3000GT, go to step 7).
6) Turn ignition switch to OFF position. With CMP sensor
connector disconnected, disconnect PCM connector. Check for continuity
between PCM connector terminal No. 50 and CMP sensor connector
terminal No. 2. If continuity does not exist, repair wiring harness as
necessary. If continuity exists, go to next step.
7) Turn ignition switch to ON position, check voltage between
chassis ground and CMP sensor connector terminal No. 2. If voltage is
not 4.8-5.2 volts, replace PCM. If voltage is as specified, condition
required to set DTC is not present at this time. Go to next step.
8) Test is complete. Intermittent problem may exist. Road
test vehicle (if necessary) and attempt to duplicate conditions that
caused original complaint. Recheck for DTCs. If no DTCs are displayed,
go to INTERMITTENT DTCS .
DTC P0400 & P0403: EXHAUST GAS RECIRCULATION (EGR) VALVE
SYSTEM FAILURE
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) If using scan tool, go to step 8). Remove EGR valve.
Inspect valve for sticking or carbon deposits. Clean or replace EGR
valve as necessary. If EGR valve is okay, go to next step.
2) Connect a vacuum pump to EGR valve. Apply 19.7-19.8 in. Hg
of vacuum. If vacuum does not hold, replace EGR valve. If vacuum
holds, go to next step.
3) Apply 1.2-1.8 in. Hg to EGR valve. Blow air through one
side of EGR valve passage. If air blows through, replace EGR valve. If
air does not blow through, go to next step.
4) Apply 9.1 in. Hg to EGR valve. Blow air through one side
of EGR valve passage. If air does not blow through, replace EGR valve.
If air blows through, reinstall EGR valve and go to next step.
5) Mark and disconnect striped vacuum hoses and wiring
connector from EGR solenoid. Install vacuum pump to EGR solenoid
white-striped vacuum hose port on turbo, or Green-striped vacuum hose
port on all other models. Apply vacuum to EGR solenoid. Go to next
step.
6) Apply and remove 12 volts across EGR solenoid terminals.
Vacuum should hold with voltage applied. Vacuum should leak without
voltage applied. If EGR solenoid does not test as specified, replace
solenoid. If solenoid tests as specified, go to next step.
7) Using DVOM, check resistance across EGR solenoid
terminals. If resistance is not 36-44 ohms at 68
F (20C), replace
solenoid. If resistance is as specified, go to step 9).
8) Turn ignition switch to ON position. Using scan tool, turn
EGR solenoid on and off (item 10). Listen for clicking sound from EGR
solenoid. If no sound is heard, replace EGR solenoid. If sound is
heard, go to next step.
9) On 3000GT, go to next step. On Montero, disconnect EGR
solenoid connector and MFI relay connector. Using DVOM, check
continuity between EGR solenoid connector terminal No. 1 and MFI relay
connector terminal No. 3. If continuity does not exist, repair wiring
harness as necessary. If continuity exists, go to step 11).
10) Disconnect EGR solenoid connector. Using DVOM, check
voltage between chassis ground and EGR solenoid connector terminal No.
1. If battery voltage does not exist, repair wiring harness as
necessary. If battery voltage exists, go to next step.
11) Turn ignition switch to OFF position. Disconnect PCM
connector. Ground PCM connector terminal No. 6. Using DVOM, check for
continuity between chassis ground and EGR solenoid connector terminal
No. 2. If continuity does not exist, repair wiring harness as
necessary. If continuity exists, condition required to set DTC is not
present at this time. Go to next step.
12) Test is complete. Intermittent problem may exist. Road
test vehicle (if necessary) and attempt to duplicate conditions that
caused original complaint. Recheck for DTCs. If no DTCs are displayed,
go to INTERMITTENT DTCS .
DTC P0420, P0421 & P0431: CATALYST EFFICIENCY BELOW
THRESHOLD
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
Specific self-diagnostic test not available from manufacturer
at time of publication. Check catalytic converter and check for
cracked exhaust manifold. Also, see F - BASIC TESTING article.
DTC P0442: EVAPORATIVE (EVAP) EMISSION CONTROL SYSTEM LEAK
DETECTED
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) Remove fuel cap. Push fuel pipe restrictor to operate On-
board Fuel Vent Valve (OFLV). Install and tighten fuel cap. Remove
fuel cap and ensure distance between filler tube and OFLV is 1.1" (28
mm). If distance is as specified, go to next step. If distance is not
as specified, replace fuel tank filler tube assembly. Go to step 24).
2) Disconnect and plug air filter-to-EVAP vent solenoid hose
at air filter. Disconnect intake manifold plenum-to-EVAP purge
solenoid at intake manifold plenum. Install a "T" fitting between
vacuum hose and intake manifold plenum. Connect a hand-held
pressure/vacuum pump to "T" fitting. Go to next step.
CAUTION: DO NOT apply more than 0.57 psi in following step. Applying
more than specified psi can crack fuel tank.
NOTE: Ensure fuel tank is at least 1/4 full. The lower the fuel
level in fuel tank, the longer it takes to pressurize fuel
system.
3) Using scan tool, read Fuel Tank Differential Pressure
(FTDP) sensor (item 73). Using hand-held pressure/vacuum pump, apply\
0.42 psi. If scan tool reading reaches 0.42 psi, go to next step. If
reading does not reach 0.42 psi, go to step 9).
4) Wait 20 seconds and read scan tool. If scan tool reading
increases 0.06 psi or less, go to next step. If scan tool reading
increases more than 0.06 psi, go to step 21).
5) Disconnect EVAP canister purge hose. Connect Purge Flow
Indicator (MB995061) between EVAP canister and disconnected hose. Turn\
engine on and allow it to reach operating temperature. Turn all lights
and accessories off. Place transmission in Park or Neutral. Observe
purge flow indicator while increasing engine RPM several times. If
purge flow indicator reads less than 2.5 SCFH (20 cm(3)/sec), check
EVAP canister purge hose and EVAP canister port for clogging. If hose
and port are okay, check EVAP purge solenoid. See DTC P0443. If
solenoid is okay, replace EVAP canister. Go to step 24).
6) Using scan tool, read Engine Coolant Temperature (ECT)
sensor temperature (item 21). Compare scan tool reading with
EVAP canister. Connect hand-held pressure/vacuum pump to hose.
Disconnect intake manifold plenum-to-EVAP purge solenoid at intake
manifold plenum. Operate vacuum pump several times to apply vacuum. If
vacuum leaks, replace EVAP canister. Go to step 24). If vacuum does
not leak, repair clog in hose between EVAP canister and EVAP Purge
solenoid. Go to step 24).
19) Disconnect EVAP canister-to-OFLV hose at OFLV. If vacuum
does not leak, repair clog in hose between EVAP canister and OFLV. Go
to step 24). If vacuum leaks, check fuel tank filler tube assembly. If
fuel tank filler tube assembly is okay, repair clog in hose between
OFLV and fuel cut-off valve. Go to step 24).
20) Replace fuel tank filler tube and OFLV-to-fuel cut-off
valve hose. While monitoring scan tool, apply 0.42 psi with hand-held
pressure/vacuum pump. If scan tool reading does not reach 0.42 psi,
replace fuel tank. Go to step 24).
21) Remove fuel cap. Install a fuel tank filler tube adapter
in place of fuel cap. Disconnect and plug air filter-to-EVAP vent
solenoid hose at air filter. Plug fuel filler tube adapter hose.
Disconnect intake manifold plenum-to-EVAP purge solenoid at intake
manifold plenum. Install a "T" fitting between vacuum hose and intake
manifold plenum. Connect hand-held pressure/vacuum pump to "T"
fitting. Go to next step.
CAUTION: DO NOT apply more than 0.57 psi in following step. Applying
more than specified psi can crack fuel tank.
NOTE: Ensure fuel tank is at least 1/4 full. The lower the fuel
level in fuel tank, the longer it takes to pressurize fuel
system.
22) Using scan tool, read Fuel Tank Differential Pressure
(FTDP) sensor (item 73). Using hand-held pressure/vacuum pump, apply\
0.42 psi. If scan tool reading rises 0.06 psi or less, replace fuel
cap. Go to step 24). If reading rises more than 0.06 psi, go to next
step.
23) Disconnect hand-held pressure/vacuum pump from "T"
fitting. Install an evaporative emission system tester in place of
vacuum held pump and apply 0.49 psi. Using an ultrasonic leak
detector, locate and repair leaks. Go to next step.
24) Road test vehicle and attempt to duplicate conditions
that caused original complaint. Recheck for DTCs. If no DTCs are
displayed, test is complete.
DTC P0443: EVAPORATIVE (EVAP) EMISSION CONTROL SYSTEM PURGE
CONTROL VALVE CIRCUIT MALFUNCTION
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) Using scan tool, turn EVAP purge solenoid on and off (item\
08). Listen for clicking sound from EVAP purge solenoid. If no sound
is heard, go to next step. If sound is heard, fault is intermittent.
See INTERMITTENT DTCS .
2) Mark and disconnect vacuum hoses, and wiring connector
from EVAP purge solenoid. Install vacuum pump to EVAP purge solenoid
Black/Red vacuum hose port. Apply vacuum to EVAP purge solenoid. Go to
next step.
3) Apply and remove 12 volts across EVAP purge solenoid
terminals. Vacuum should hold without voltage applied. Vacuum should
leak with voltage applied. If EVAP purge solenoid does not test as
specified, replace EVAP purge solenoid. Go to step 8). If EVAP purge
solenoid tests as specified, go to next step.
4) Using DVOM, check resistance across EVAP purge solenoid
terminals. If resistance is not 36-44 ohms at 68F (20C), replace
EVAP purge solenoid. Go to step 8). If resistance is as specified, go
to next step.
5) On 3000GT, go to next step. On Montero, disconnect EVAP
purge solenoid connector and MFI relay connector. Using DVOM, check
continuity between EVAP purge solenoid connector terminal No. 1 and
MFI relay connector terminal No. 1. If continuity does not exist,
repair wiring harness as necessary. If continuity exists, go to step
7).
6) Disconnect EVAP purge solenoid connector. Using DVOM,
check voltage between chassis ground and EVAP purge solenoid connector
terminal No. 1. If battery voltage does not exist, repair wiring
harness as necessary. If battery voltage exists, go to next step.
7) Turn ignition switch to OFF position. Disconnect PCM
connector. Ground PCM connector terminal No. 16. Using DVOM, check for
continuity between chassis ground and EVAP purge solenoid connector
terminal No. 2. If continuity does not exist, repair wiring harness as
necessary. If continuity exists, condition required to set DTC is not
present at this time. Go to next step.
8) Road test vehicle and attempt to duplicate conditions that
caused original complaint. Recheck for DTCs. If no DTCs are displayed,
test is complete.
DTC P0446: EVAPORATIVE (EVAP) EMISSION CONTROL SYSTEM VENT
CONTROL MALFUNCTION
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) Using scan tool, turn EVAP vent solenoid on and off (item
29). Listen for clicking sound from EVAP vent solenoid. If no sound is
heard, go to next step. If sound is heard, fault is intermittent. See
INTERMITTENT DTCS .
2) Disconnect EVAP vent solenoid connector and MFI relay
connector. Using DVOM, check continuity between EVAP vent solenoid
connector terminal No. 1 and MFI relay connector terminal No. 1. If
continuity does not exist, repair wiring harness as necessary. If
continuity exists, go to next step.
3) Turn ignition switch to OFF position. Disconnect PCM
connector. Ground PCM connector terminal No. 35. Using DVOM, check for
continuity between chassis ground and EVAP vent solenoid connector
terminal No. 2. If continuity does not exist, repair wiring harness as
necessary. If continuity exists, condition required to set DTC is not
present at this time. Go to next step.
4) Road test vehicle and attempt to duplicate conditions that
caused original complaint. Recheck for DTCs. If no DTCs are displayed,
test is complete.
DTC P0450: EVAPORATIVE (EVAP) EMISSION CONTROL SYSTEM
PRESSURE SENSOR MALFUNCTION
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) Using scan tool, check Fuel Tank Differential Pressure
(FTDP) sensor pressure (item 73). Pressure should be -0.48-0.48 psi.\
If pressure is not as specified, go to next step. If pressure is as
specified, fault is intermittent. See INTERMITTENT DTCS.
2) Remove fuel cap. Install a fuel tank filler tube adapter
in place of fuel cap. Connect a hand-held pressure/vacuum pump to fuel
tank filler adapter hose. Go to next step.
CAUTION: DO NOT apply more than 1.0 psi in following step. Applying
more than specified psi can crack fuel tank.
NOTE: Ensure fuel tank is at least 1/4 full. The lower the fuel
level in fuel tank, the longer it takes to pressurize fuel
system.
3) Apply 1.0 psi. Using scan tool, read Fuel Tank
Differential Pressure (FTDP) sensor (item 73). If scan tool reads mo\
re
than 0.86 psi, go to next step. If reading is 0.86 psi or less, fault
is intermittent. See INTERMITTENT DTCS.
4) Check On-Board Fuel Vent Valve (OFLV) for clogging. OFLV
is located in fuel tank filler tube assembly. If OFLV is clogged,
replace fuel tank filler tube assembly. Go to step 10). If OFLV is
okay, go to next step.
5) Check EVAP hoses, and purge and vent solenoids for
clogging. Repair or replace as necessary. Go to step 10). If hoses and
solenoids are okay, go to next step.
6) Disconnect FTDP connector. Ensure ignition is off. Using
DVOM, check for continuity between ground and FTDP sensor connector
terminal No. 2. If continuity does not exist, repair wiring harness as
necessary. If continuity exists, go to next step.
7) Disconnect PCM connector. Ground PCM connector terminal
No. 93. Using DVOM, check for continuity between chassis ground and
FTDP sensor connector terminal No. 1. If continuity does not exist,
repair wiring harness as necessary. If continuity exists, go to next
step.
8) Turn ignition on. Using DVOM, check voltage between ground
and FTDP sensor connector terminal No. 3. Voltage should be 4.8-5.2
volts. If voltage is not as specified, replace PCM. If voltage is as
specified, go to next step.
9) Inspect connectors and wiring harness between FTDP sensor
and PCM. Repair as necessary. If connectors and wiring harness are
okay, go to next step.
10) Road test vehicle and attempt to duplicate conditions
that caused original complaint. Recheck for DTCs. If no DTCs are
displayed, test is complete.
DTC P0455: EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM LARGE
LEAK DETECTED
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) Remove fuel cap. Push fuel pipe restrictor to operate On-
board Fuel Vent Valve (OFLV). Install and tighten fuel cap. Remove
fuel cap and ensure distance between filler tube and OFLV is 1.1" (28
mm). If distance is as specified, go to next step. If distance is not
as specified, replace fuel tank filler tube assembly. Go to step 20).
2) Disconnect and plug air filter-to-EVAP vent solenoid hose
at air filter. Disconnect intake manifold plenum-to-EVAP purge
solenoid at intake manifold plenum. Install a "T" fitting between
vacuum hose and intake manifold plenum. Connect a hand-held
pressure/vacuum pump to "T" fitting. Go to next step.
CAUTION: DO NOT apply more than 0.57 psi in following step. Applying
more than specified psi can crack fuel tank.
NOTE: Ensure fuel tank is at least 1/4 full. The lower the fuel
level in fuel tank, the longer it takes to pressurize fuel
VACUUM DIAGRAMS article. Install hoses as necessary and go to step
20). If hoses are okay, go to next step.
14) Disconnect OFLV-to-EVAP canister hose at OFLV and EVAP
canister. Plug hose at OFLV end. Connect hand-held pressure/vacuum
pump to hose at EVAP canister end. Apply 0.9 psi. If pressure is not
maintained, replace hose. Go to step 20). If pressure is maintained,
go to next step.
15) Using scan tool, read Fuel Tank Differential Pressure
(FTDP) sensor (item 73). Connect hand-held pressure/vacuum pump to
OFLV. While monitoring scan tool, apply 0.42 psi. If scan tool reading
reaches 0.42 psi, go to next step. If reading does not reach 0.42 psi,
go to step 19).
16) Disconnect OFLV-to-EVAP canister hose at EVAP canister.
Connect hand-held pressure/vacuum pump to hose and apply 0.9 psi. If
pressure is not maintained, go to next step. If pressure is
maintained, go to step 18).
17) Disconnect EVAP purge solenoid-to-EVAP canister hose at
EVAP canister. Connect hand-held pressure/vacuum pump to hose.
Disconnect intake manifold plenum-to-EVAP purge solenoid at intake
manifold plenum. Operate vacuum pump several times to apply vacuum. If
vacuum leaks, replace EVAP canister. Go to step 20). If vacuum does
not leak, repair clog in hose between EVAP canister and EVAP Purge
solenoid. Go to step 20).
18) Disconnect EVAP canister-to-OFLV hose at OFLV. If vacuum
does not leak, repair clog in hose between EVAP canister and OFLV. Go
to step 20). If vacuum leaks, check fuel tank filler tube assembly. If
fuel tank filler tube assembly is okay, repair clog in hose between
OFLV and fuel cut-off valve. Go to step 20).
19) Replace fuel tank filler tube and OFLV-to-fuel cut-off
valve hose. While monitoring scan tool, apply 0.42 psi with hand-held
pressure/vacuum pump. If scan tool reading does not reach 0.42 psi,
replace fuel tank. Go to next step.
20) Road test vehicle and attempt to duplicate conditions
that caused original complaint. Recheck for DTCs. If no DTCs are
displayed, test is complete.
DTC P0500: VEHICLE SPEED SENSOR (VSS) CIRCUIT FAILURE
NOTE: Speedometer testing procedures for 3000GT are not available
from manufacturer at time of publication. For terminal
identification, see TERMINAL IDENTIFICATION.
For circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) If using scan tool, go to step 4). On 3000GT, go to step
3). On Montero, speedometer testing procedures using DVOM require
removal of instrument panel. Removal and installation of instrument
panel is basically an unbolt and bolt-on procedure.
2) DO NOT disconnect connectors. Using DVOM, check continuity
between indicated speedometer terminals. See Fig. 40. Ensure
continuity pulses on and off with speedometer shaft revolution. If
continuity is not as specified, replace speedometer. If continuity is
as specified, go to next step.
specified VSS connector terminal. See
VSS VOLTAGE FEED CIRCUIT IDENTIFICATION table. If voltage is not 4.5-
4.9 volts, replace PCM. If voltage is as specified, condition required
to set DTC is not present at this time. Go to next step.
VSS VOLTAGE FEED CIRCUIT IDENTIFICATION TABLE
\
\
\
\
\
\
Application Terminal No.
Montero ................................................ 1
3000GT ................................................. 3
\
\
\
\
\
\
9) Test is complete. Intermittent problem may exist. Road
test vehicle (if necessary) and attempt to duplicate conditions that
caused original complaint. Recheck for DTCs. If no DTCs are displayed,
go to INTERMITTENT DTCS .
DTC P0505: IDLE CONTROL SYSTEM FAILURE
NOTE: For terminal identification, see TERMINAL IDENTIFICATION. For
circuit and wire color identification, see
L - WIRING DIAGRAMS article.
1) Procedures are provided by manufacturer for component
testing using an engine analyzer with oscilloscope capability. Refer
to manufacturer's operation manual for instructions in use of
oscilloscope. If using engine analyzer, go to step 3). If using scan
tool, go to next step.
2) Using scan tool, read Idle Air Control (IAC) position
sensor step (item 45). See IAC POSITION SENSOR STEP SPECIFICATIONS
table. If scan tool does not read as specified, replace IAC position
sensor. If readings are as specified, go to step 5).
IAC POSITION SENSOR STEP SPECIFICATIONS TABLE
\
\
\
\
\
\
A/C Switch Position Standard Step Value
Off ................................................. 2-25
Off To On ............................ Increase From 10-70
( 1) ................................... Increase From 5-50
( 1) - Brakes applied. A/C Off on Montero. A/C On on 3000GT.
Move gear selector lever to Drive position.
\
\
\
\
\
\
NOTE: Check wave pattern when idle speed increases when A/C is
turned on. Wave pattern display lasts less than one second.
3) Disconnect IAC motor connector. Install Test Harness
(MB998463) between IAC motor and connector. Using engine analyzer with\
oscilloscope capability, connect special patterns probe in sequence to
test harness terminals No. 1 (Red clip), 3 (Blue clip), 4 (Black cl\
ip)
and 6 (Yellow clip) or PCM terminals No. 4, 5, 17 and 18 respectively.\
Start engine and allow it to idle. Turn A/C on. Compare oscilloscope
wave pattern with known-good wave pattern. See Fig. 44. Turn engine
off. If wave pattern is not normal, go to next step. If wave pattern
is normal, fault is intermittent. See INTERMITTENT DTCS.