1998 DODGE RAM 1500 Valve

[x] Cancel search: Valve

Page 2070 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual imately at the upper COLD hole of the dipstick at
70É F fluid temperature.
NOTE: Engine and Transmission should be at nor-
mal operating temperature before performing this
procedure.
(1) Start engine

Page 2071 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (11) Remove and discard the oil filter seal from the
bottom of the oil pump.
(12) If replacing the cooler return filter, use Oil
Filter Wrench 8321 to remove the filter from the
transmission.
(13) Dis

Page 2076 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INPUT CLUTCH ASSEMBLY
DESCRIPTION
Three hydraulically applied input clutches are used
to drive planetary components. The underdrive, over-
drive, and reverse clutches are considered input
clutches and

Page 2080 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Fig. 81 Input Clutch Assembly - Part 1
1 - INPUT CLUTCH HUB 11 - UD CLUTCH
2 - O-RING SEALS 12 - PLATE
3 - SEAL 13 - CLUTCH RETAINER
4 - SNAP-RING 14 - SEAL
5 - SNAP-RING 15 - OD/REV PISTON
6 - UD BAL

Page 2081 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ASSEMBLY
(1) Install all new seals and o-rings onto the input
shaft and input hub. The o-rings on the input hub
are color coded. Be sure to install the correct o-ring
in the correct location.
(2) Chec

Page 2089 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (13) Measure the low/reverse clutch pack clearance
and adjust as necessary. The correct clutch clearance
is 1.00-1.74 mm (0.039-0.075 in.).
(14) Install the overrunning clutch into the low/re-
verse c

Page 2090 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual CONVERTER CLUTCH REGULATOR VALVE
The converter clutch regulator valve is used to con-
trol the hydraulic pressure supplied to the back (ON)
side of the torque converter clutch.
TORQUE CONVERTER LIMIT

Page 2091 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (3) If one quart of transmission fluid is collected in
the container in 30 seconds or less, oil pump flow vol-
ume is within acceptable limits. If fluid flow is inter-
mittent, or it takes more than 3