1998 DODGE RAM 1500 Valve

[x] Cancel search: Valve

Page 2029 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (43) Remove the park pawl rod and e-clip (Fig. 31).
(44) Remove the park pawl rod guide snap-ring
(Fig. 31).
(45) Remove the park pawl rod guide (Fig. 31).
(46) Remove the park pawl pivot shaft, park

Page 2030 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (5) Install the manual selector shaft and retaining
screw. Tighten the manual selector shaft retaining
screw to 28 N´m (250 in.lbs.).
(6) Install the park pawl, spring, and shaft (Fig.
33).
(7) Insta

Page 2031 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual specification, the reaction plate, all the friction discs,
and steels must be replaced.
(16) Remove the 4C retainer/bulkhead and all of
the 2C clutch components from the transmission
case.
(17) Instal

Page 2034 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (31) Install the output shaft selective thrust plate
onto the reaction annulus with the oil grooves facing
the annulus gear and the tabs and notches aligned as
shown in (Fig. 42).
(32) Install the num

Page 2036 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (46) Install the transmission front cover into the
transmission case (Fig. 48).
(47) Install the outer snap-ring to hold the trans-
mission front cover into the transmission case (Fig.
48).
(48) Parti

Page 2037 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual o-ring is properly installed and is free of any debris.
The hub must be smooth to avoid damaging pump
seal at installation.
(2) If a replacement transmission is being
installed, transfer any component

Page 2061 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual SPECIFICATIONS
TRANSMISSION
GENERAL
Component Metric Inch
Output Shaft End Play 0.22-0.55
mm0.009-0.021
in.
Input Shaft End Play 0.46-0.89
mm0.018-0.035
in.
2C Clutch Pack
Clearance0.455-1.335
mm0.018

Page 2069 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual FLUID AND FILTER
DIAGNOSIS AND TESTING
DIAGNOSIS AND TESTING - EFFECTS OF
INCORRECT FLUID LEVEL
A low fluid level allows the pump to take in air
along with the fluid. Air in the fluid will cause fluid