DODGE RAM 1500 1998 2.G Workshop Manual IAC Stepper Motor Program:The PCM is also
equipped with a memory program that records the
number of steps the IAC stepper motor most recently
advanced to during a certain set of parameters. For
exampl

Page 1599 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INTAKE AIR TEMPERATURE
SENSOR
DESCRIPTION
The 2±wire Intake Manifold Air Temperature (IAT)
sensor is installed in the intake manifold with the
sensor element extending into the air stream.
The IAT se

Page 1600 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (3) Gently lift on small plastic release tab (Fig. 17)
or (Fig. 18) and rotate sensor about 1/4 turn counter-
clockwise for removal.
(4) Check condition of sensor o-ring.
5.7L V-8
The intake manifold

Page 1601 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (3) Position sensor into intake manifold and rotate
clockwise until past release tab.
(4) Install electrical connector.
5.7L V-8
The intake manifold air temperature (IAT) sensor
is installed into the

Page 1602 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ²Engine load
²Injector pulse-width
²Spark-advance programs
²Shift-point strategies (certain automatic trans-
missions only)
²Idle speed
²Decel fuel shutoff
The MAP sensor signal is provided from

Page 1603 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual 5.7L V-8
The Manifold Absolute Pressure (MAP) sensor is
mounted to the front of the intake manifold air ple-
num box (Fig. 24).
(1) Disconnect electrical connector at sensor by
sliding release lock ou

Page 1604 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (4) Install MAP sensor mounting bolts (screws).
Refer to Torque Specifications.
(5) Connect electrical connector.
5.7L V-8
The Manifold Absolute Pressure (MAP) sensor is
mounted to the front of the in

Page 1605 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
Threads of new oxygen sensors are factory coated
with anti-seize compound to aid in removal.DO
NOT add any additional anti-seize compound to
threads of a new oxygen sensor.
(1) Install O2