1998 DODGE RAM 1500 TcM

[x] Cancel search: TcM

Page 2086 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual feedback loop to the TCM. The TCM uses this infor-
mation to adjust its control of the pressure control
solenoid to achieve the desired line pressure.
OPERATION
The TCM calculates the desired line pre

Page 2094 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual into the appropriate oil pump valve body bore (Fig.
102) (Fig. 103).
(4) Place the separator plate onto the oil pump
body (Fig. 101).
(5) Install the screws to hold the separator plate
onto the oil pu

Page 2105 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual STATOR
The stator assembly (Fig. 120) is mounted on a sta-
tionary shaft which is an integral part of the oil
pump. The stator is located between the impeller and
turbine within the torque converter c

Page 2107 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual control switch is in the OFF position, the clutch will
engage after the shift to third gear.
The TCM controls the torque converter by way of
internal logic software. The programming of the soft-
ware

Page 2108 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (9) Fill the transmission with the recommended
fluid.
TRANSMISSION CONTROL
RELAY
DESCRIPTION
The relay is supplied fused B+ voltage, energized
by the TCM, and is used to supply power to the sole-
noid

Page 2109 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual TRANSMISSION SOLENOID/
TRS ASSEMBLY
DESCRIPTION
The transmission solenoid/TRS assembly is inter-
nal to the transmission and mounted on the valve
body assembly (Fig. 126). The assembly consists of
six

Page 2110 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual PRESSURE SWITCHES
The TCM relies on five pressure switches to moni-
tor fluid pressure in the L/R, 2C, 4C, UD, and OD
hydraulic circuits. The primary purpose of these
switches is to help the TCM detec

Page 2111 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
(1) Place TRS selector plate in the PARK position.
(2) Position the transmission solenoid/TRS assem-
bly onto the valve body. Be sure that both alignment
dowels are fully seated in the va