DODGE RAM 1500 1998 2.G Workshop Manual INTAKE AIR HEATER
DESCRIPTION
The intake manifold air heater element assembly
is located in the top of the intake manifold.
OPERATION
The air heater elements are used to heat incoming
air to the intak

Page 1650 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (5) Install engine oil dipstick tube and mounting
bolt.
(6) Connect rubber connector hose and intake tube
to air intake housing. Tighten clamp bolts to 11 N´m
(95 in. lbs.) torque.
(7) Connect both n

Page 1651 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INTAKE AIR HEATER RELAY
DESCRIPTION
The 2 intake manifold air heater relays are located
in the engine compartment. They are attached to a
common bracket. This bracket is attached to the
right battery

Page 2297 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual VISUAL INSPECTION BEFORE WATER LEAK TESTS
Verify that floor and body plugs are in place, body
drains are clear, and body components are properly
aligned and sealed. If component alignment or seal-
ing

Page 2488 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual HEATING & AIR CONDITIONING
TABLE OF CONTENTS
page page
HEATING & AIR CONDITIONING
DESCRIPTION
DESCRIPTION - ENGINE COOLING
SYSTEM REQUIREMENTS...............1
DESCRIPTION - HEATER AND AIR
CONDITIONER.

Page 2489 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ber above the heating, ventilation and air condition-
ing (HVAC) housing. On models equipped with air
conditioning, the air passes through the evaporator
coil. Air flow can be directed either through

Page 2490 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual The panel outlets receive airflow from the HVAC
housing through a molded plastic main panel duct,
center panel duct and two end panel ducts. The two
end panel ducts direct airflow to the left and righ

Page 2493 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual Condition Possible Causes Correction
The low side pressure is too
low, and the high side
pressure is too high.1. Restricted refrigerant flow
through the refrigerant lines.1. See Liquid, Suction, and D