1998 DODGE RAM 1500 Ignition switch

[x] Cancel search: Ignition switch

Page 559 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual HEADLAMP DIAGNOSIS
CONDITION POSSIBLE CAUSES CORRECTION
HEADLAMPS ARE DIM
WITH ENGINE IDLING
OR IGNITION TURNED
OFF1. Loose or corroded battery
cables.1. Clean and secure battery cable clamps and
post

Page 560 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual CONDITION POSSIBLE CAUSES CORRECTION
HEADLAMPS DO NOT
ILLUMINATE1. No voltage to headlamps. 1. Repair open headlamp circuit, refer to
Electrical, Wiring Information.
2. No ground at headlamps. 2. Repa

Page 563 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (2) Install the lamp back plate onto the tail lamp
unit.
(3) Install the tail lamp unit (Refer to 8 - ELEC-
TRICAL/LAMPS/LIGHTING - EXTERIOR/TAIL
LAMP UNIT - INSTALLATION).
(4) Reconnect the negative

Page 569 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (1) Position the front fog lamp relay to the proper
receptacle in the Power Distribution Center (PDC).
(2) Align the front fog lamp relay terminals with
the terminal cavities in the PDC.
(3) Press fir

Page 581 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual LAMPS/LIGHTING - INTERIOR
TABLE OF CONTENTS
page page
DOME LAMP
DESCRIPTION.........................26
OPERATION...........................26
REMOVAL.............................26
INSTALLATION.......

Page 583 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual INSTALLATION
(1) Reach through the glove box opening and
behind the glove box lamp and switch mounting
bracket to feed the instrument panel wire harness
connectors out through the hole in the glove bo

Page 587 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual The compass unit also will compensate for magne-
tism the body of the vehicle may acquire during nor-
mal use. However, avoid placing anything magnetic
directly on the roof of the vehicle. Magnetic mo

Page 588 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual SELF-DIAGNOSTIC TEST
A self-diagnostic test is built-in to the module to
determine that the electronics module is operating
properly, and that all the J1850 PCI data bus mes-
sages are being received