1998 DODGE RAM 1500 Motor mount

[x] Cancel search: Motor mount

Page 2511 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual RECIRCULATION DOOR
ACTUATOR
DESCRIPTION
The recirculation door actuator is a reversible
12-volt Direct Current (DC) servo motor. The single
recirculation door actuator is located on the passen-
ger si

Page 2522 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual DISASSEMBLY
(1) Remove the HVAC housing from the vehicle
and place it on the workbench (Refer to 24 - HEAT-
ING & AIR CONDITIONING/DISTRIBUTION/HVAC
HOUSING - REMOVAL).
(2) Disconnect the electrical c

Page 2523 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual ING/CONTROLS/BLOWER MOTOR RESISTOR
BLOCK - INSTALLATION).
(5) If removed, install the blower motor (Refer to
24 - HEATING & AIR CONDITIONING/DISTRIBU-
TION/BLOWER MOTOR - INSTALLATION).
(6) Install th

Page 2535 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual After the system has been tested for leaks and
evacuated, a refrigerant (R-134a) charge can be
injected into the system.
NOTE: When connecting the service equipment
coupling to the line fitting, verif

Page 2539 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (11) Install the serpentine drive belt (Refer to 7 -
COOLING/ACCESSORY DRIVE/DRIVE BELTS -
INSTALLATION).
(12) Reconnect the battery negative cable.
(13) Evacuate the refrigerant system (Refer to 24 -

Page 2540 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual REMOVAL - 5.9L DIESEL ENGINE
WARNING: REVIEW THE WARNINGS AND CAU-
TIONS IN THE FRONT OF THIS SECTION BEFORE
PERFORMING THE FOLLOWING OPERATION (Refer
to 24 - HEATING & AIR CONDITIONING/PLUMBING -
WAR

Page 2541 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (4) Align the condenser lower mounting tabs to the
mounting flanges.
(5) Install the two bolts that secure the condenser/
cooling fan assembly to the upper front crossmember.
Tighten the bolts to 10.5

Page 2542 of 2627

DODGE RAM 1500 1998 2.G Workshop Manual (10) Connect the discharge line to the condenser
inlet port.
(11) Install and tighten the nut that secures the
discharge line fitting to the condenser. Tighten the
nut to 20 N´m (180 in. lbs.).
(12)