ACURA INTEGRA 1998  Service Repair Manual 7.
10 x 1.25 mm1+4 N.m (4.5 kgt.m,33 tbf.ft)
TOROUECONVERTERCOVER
EI{GINESTIFFEI{ER
I x 1.25 mm24 N.m 12.4 kgf.m,17 rbf.ftl
8.
Remove the transmission jack.
Attach the torque converter to the drive pl

Page 593 of 1680

ACURA INTEGRA 1998  Service Repair Manual I
Shift lndicator Panel
Adjustment
CAUTION:
a All SRS wire harnesses ate covered with yellow insu-
lation. Belore you disconnect any part ol an SRS wire
harness, disconnect the airbag connectols
a Wh

Page 652 of 1680

ACURA INTEGRA 1998  Service Repair Manual System Description
Fluid Flow Diagram
The system is a compact rotary-valve-type power steering, connected to the steering gearbox. The fluid pressure is pro-
vided by a vane-type pump which is driven

Page 654 of 1680

ACURA INTEGRA 1998  Service Repair Manual System Description
Steering Pump (contd) .
 
17-6
Flow Control
The flow control valve in the pump performs the follow-
ing steps O through aE ro control the flow of fluid, i.e. to
increase the discha

Page 667 of 1680

ACURA INTEGRA 1998  Service Repair Manual I
Steering Linkage and Gearbox
STEERING COLUMNInspect tor loose columnmounting bolts and nuts.
TIE.ROD END BALL JOINTInspect tor faultv movementano oamage,
BOOTInspect lor damage and deterioration.
ST

Page 668 of 1680

ACURA INTEGRA 1998  Service Repair Manual Inspection and Adjustment
Pump Belt
NOTE: When using a new belt, first adjust the deflection
or tension to the values for the new belt, then readjust
the deflection or tension to the values for the us

Page 683 of 1680

ACURA INTEGRA 1998  Service Repair Manual Power Steering Pump
Replacement
NOTE: Before disconnecting the hoses from the pump,
place a suitable container under the vehicle.
1. Remove the belt by loosening the pump adjusting
bolt, mounting bolt

Page 691 of 1680

ACURA INTEGRA 1998  Service Repair Manual 15. Disconnect the two lines from the valve bodv unit
on the steering gearbox.
CAUTION: After disconnscting the hose and line,plug or seal the hose and lino whh I pi6ce ot tape
o. oquivalent to prevon