ENGINE ELECTRICAL ± Charging System16-6
This test determines whether the alternator output
current is normal.
(1) Before the test, always be sure to check the
following.
Alternator installation
Battery (Refer to GROUP 54 ± Battery.)
NOTE
The battery should be slightly discharged.
The load needed by a fully-charged battery
is insufficient for an accurate test.
Alternator drive belt tension (Refer to
GROUP 11 ± On-vehicle Service.)
Fusible link
Abnormal noise from the alternator while
the engine is running.
(2) Turn the ignition switch off.
(3) Disconnect the negative battery cable.
(4) Disconnect the alternator output wire from the
alternator ªBº terminal. Connect a DC test
ammeter with a range of 0 ± 100 A in series
between the ªBº terminal and the disconnected
output wire. (Connect the (+) lead of the
ammeter to the ªBº terminal. Connect the (±)
lead of the ammeter to the disconnected output
wire.)
Caution
Never use clips but tighten bolts and nuts
to connect the line. Otherwise loose
connections (e.g. using clips) will lead to
a serious accident because of high current.
NOTE
An inductive-type ammeter which enables
measurements to be taken without
disconnecting the alternator output wire should
be recommended.
(5) Connect a voltmeter with a range of 0 ± 20 V
between the alternator ªBº terminal and the
earth. (Connect the (+) lead of the voltmeter
to the ªBº terminal, and then connect the (±)
lead of the voltmeter to the earth.)
(6) Connect the negative battery cable.
(7) Connect a tachometer. (Refer to GROUP 11
± On-vehicle Service.)
(8) Leave the hood open.
(9) Check that the reading on the voltmeter is equal
to the battery voltage.
NOTE
If the voltage is 0 V, the cause is probably
an open circuit in the wire or fusible link between
the alternator ªBº terminal and the battery (+)
terminal.(10)Turn the light switch on to turn on headlamps
and then start the engine.
(11) Immediately after setting the headlamps to high
beam and turning the heater blower switch to
the high revolution position, increase the engine
speed to 2,500 r/min and read the maximum
current output value displayed on the ammeter.
Limit: 70% of normal current output
NOTE
For the nominal current output, refer to the
Alternator Specifications.
Because the current from the battery will
soon drop after the engine is started, the
above step should be carried out as quickly
as possible in order to obtain the maximum
current output value.
The current output value will depend on
the electrical load and the temperature of
the alternator body.
If the electrical load is small while testing,
the specified level of current may not be
output even though the alternator is normal.
In such cases, increase the electrical load
by leaving the headlamps turned on for
some time to discharge the battery or by
using the lighting system in another vehicle,
and then test again.
The specified level of current also may not
be output if the temperature of the alternator
body or the ambient temperature is too
high. In such cases, cool the alternator and
then test again.
(12)The reading on the ammeter should be above
the limit value. If the reading is below the limit
value and the alternator output wire is normal,
remove the alternator from the engine and
check the alternator.
(13)Run the engine at idle after the test.
(14)Turn the ignition switch off.
(15)Remove the tachometer.
(16)Disconnect the negative battery cable.
(17)Disconnect the ammeter and voltmeter.
(18)Connect the alternator output wire to the
alternator ªBº terminal.
(19)Connect the negative battery cable.
ENGINE ELECTRICAL ± Charging System16-8
(14)If the voltage reading conforms to the value
in the voltage regulation, then the voltage
regulator is operating normally.
If the voltage is not within the standard value,
there is a malfunction of the voltage regulator
or of the alternator.
(15)After the test, lower the engine speed to the
idle speed.
(16)Turn the ignition switch off.(17)Remove the tachometer.
(18)Disconnect the negative battery cable.
(19)Disconnect the ammeter and voltmeter.
(20)Connect the alternator output wire to the
alternator ªBº terminal.
(21)Remove the special tool, and return the
connector to the original condition.
(22)Connect the negative battery cable.
Voltage Regulation Table
Standard value:
Inspection terminalVoltage regulator ambient temperature CVoltage V
Terminal ªSº±2014.2 ± 15.4
2013.9 ± 14.9
6013.4 ± 14.6
8013.1 ± 14.5
CHASSIS ELECTRICAL ± Battery54-5
CHARGING54100110029
1. When charging a battery while still installed in the vehicle,
disconnect the battery cables to prevent damage to
electrical parts.
2. The current normally used for charging a battery should
be approximately 1/10th of the battery capacity.
3. When performing a quick-charging due to lack of time,
etc., the charging current should never exceed the battery
capacity as indicated in amperes.
4. Determining if charging is completed.
(1) If the specific gravity of the battery fluid reaches
1.250 ± 1.290 and remains constant for at least one
hour.
(2) If the voltage of each cell reaches 2.5 ± 2.8 V and
remains constant for at least one hour.
Caution
1. Be careful since the battery fluid level may rise
during charging.
2. Keep all sources of fire away while charging
because there is a danger of explosion.
3. Be careful not to do anything that could generate
sparks while charging.
4. When charging is completed, replace the battery
caps, pour clean water over the battery to remove
any sulfuric acid and dry.
CHASSIS ELECTRICAL ± Battery54-6
BATTERY TESTING PROCEDURE54100120107
TEST STEP
(1) Turn headlamps on for 15 seconds.
(2) Turn headlamps off for 2 minutes to allow battery voltage to
stabilize.
(3) Disconnect cables.
OK
Read open circuit voltage.
OK:Open circuit voltage is more than 12.4 VNGCharge battery at 5 amps. (see LOAD TEST RATE CHART)
RetestOK
(1) Connect a load tester to the battery.
(2) Load the battery at the recommended discharge rate (see LOAD
TEST RATE CHART) for 15 seconds.
(3) Read voltage after 15 seconds, then remove load.
(4) Compare the measured value with the minimum voltage (see
LOAD TEST CHART).
OK:Higher than minimum voltageNG
Replace battery
OK
Normal
LOAD TEST RATE CHART
Battery type50B24R55D23R55B24R75D26R80D26R95D31R
Charging time when fully discharged h
[5-amp rated current charging]8108121214
Load test (Amps)190170210240290310
LOAD TEST CHART
Temperature C21 and
above16104±1±7±12±18
Minimum voltage V9.69.59.49.39.18.98.78.5
General Information/Service Specifications/
Lubricants/Sealant HEATER, AIR CONDITIONER
AND VENTILATION ±55-4
Caution
Do not heat R-134a above 40C
In most instances, moderate heat is required to
bring the pressure of the refrigerant in its container
above the pressure of the system when charging
or adding refrigerant.
A bucket or large pan of hot water not over 40C
is all the heat required for this purpose. Do not
heat the refrigerant container with a blow torch
or any other means that would raise temperature
and pressure above this temperature. Do not weld
or steam clean on or near the system components
or refrigerant lines.
Caution
Keep R-134a containers upright when charging
the system.When metering R-134a into the refrigeration system
keep the supply tank or cans in an upright position.
If the refrigerant container is on its side or upside
down, liquid refrigerant will enter the system and
damage the compressor.
Caution
1. The leak detector for R-134a should be used
to check for refrigerant gas leaks.
2. Do not allow liquid refrigerant to touch bright
metal.
Refrigerant will tarnish bright metal and chrome
surfaces, and in combination with moisture can
severely corrode all metal surfaces.
SERVICE SPECIFICATIONS55200030141
ItemsStandard value
Idle speed r/min4G6750+100
4D5750+100
Idle up speed r/min900+50
Resistor (for blower motor)
Resistor (for blower motor)
Air gap (Magnetic clutch) mm0.3 ± 0.6
Engine coolant tempera-
ture switch (for A/C cut-off)
ON (continuity)108 or less
ture switch (for A/C cut-off)
<4D5> COFF (no continuity)115 or more
Engine coolant tempera-
ture switch (for condenser
ON (continuity)102 or more
ture switch (for condenser
fan) <4D5> COFF (no continuity)97 or less
LUBRICANTS55200040137
ItemsSpecified lubricantsQuantity
Each connection of refrigerant lineZXL100PGAs required
Compressor refrigerant unit lubricant mZXL100PG180
SEALANT55200050048
ItemSpecified sealantRemark
Engine coolant temperature switch threaded
part3M Nut Locking Part No. 4171 or equivalentDrying sealant
± On-vehicle Service HEATER, AIR CONDITIONER
AND VENTILATION55-14
Performance Temperature Chart
Garage ambient temperature C20253540
Discharge air temperature C3.6 ± 9.54.0 ± 11.07.0 ± 9.011.0 ± 13.8
Compressor high pressure kPa1,1201,2361,8142,050
Compressor low pressure kPa11 5131152175
REFRIGERANT LEAK REPAIR55200150083
LOST CHARGE
If the system has lost all charge due to a leak:
1. Evacuate the system. (See procedure.)
2. Charge the system with approximately one
pound of refrigerant.
3. Check for leaks.
4. Discharge the system.
5. Repair leaks.
6. Replace receiver drier.
Caution
Replacement filter-drier units must be
sealed while in storage. The drier used in
these units will saturate water quickly upon
exposure to the atmosphere. When
installing a drier, have all tools and supplies
ready for quick reassembly to avoid keeping
the system open any longer than necessary.
7. Evacuate and charge system.
LOW CHARGE
If the system has not lost all of its refrigerant charge;
locate and repair all leaks. If it is necessary to
increase the system pressure to find the leak
(because of an especially low charge) add
refrigerant. If it is possible to repair the leak without
discharging the refrigerant system, use the
procedure for correcting low refrigerant level.HANDLING TUBING AND FITTINGS
Kinks in the refrigerant tubing or sharp bends in
the refrigerant hose lines will greatly reduce the
capacity of the entire system. High pressures are
produced in the system when it is operating.
Extreme care must be exercised to make sure that
all connections are pressure tight. Dirt and moisture
can enter the system when it is opened for repair
or replacement of lines or components. The
following precautions must be observed. The
system must be completely discharged before
opening any fitting of connection in the refrigeration
system. Open fittings with caution even after the
system has been discharged. If any pressure is
noticed as a fitting is loosened, allow trapped
pressure to bleed off very slowly.
Never attempt to rebend formed lines to fit. Use
the correct line for the installation you are servicing.
A good rule for the flexible hose lines is keep the
radius of all bends at least 10 times the diameter
of the hose.
Sharper bends will reduce the flow of refrigerant.
The flexible hose lines should be routed so that
they are at least 80 mm from the exhaust manifold.
It is good practice to inspect all flexible hose lines
at least once a year to make sure they are in good
condition and properly routed.
Unified plumbing connections with O-rings, these
O-rings are not reusable.