24-100
      
- 
Press  button.     
-  Select "End Output" function 06 and press -Q- 
button to confirm input. 
      If a display did NOT change, even though coding 
is OK:  
     
-  Connect VAG 1598/19 test box to ECM harness 
connector  page 01
-255
 . 
     
-  Connect VAG 1527B voltage tester between test 
box sockets 11B (signal) and 10B (constant 
B+/terminal 30). 
     
Voltage tester must light up (with TR selector 
lever in P or N), then go out with drive mode 
(1, 2, 3, R or D) selected 
      If voltage tester lights up and goes out when 
drive mode is selected, even though the range 
indicator in the "Read measuring value block" is 
OK:  
     
- Replace ECM   page 01
-265
 .
      If voltage tester lights up constantly or not at all:  
    
- 
Check wiring for short to ground, short to B+ or open circuit between 
Pa