Page 1199 of 1202
AC3IW-01
AC-70
- AIR CONDITIONINGHEATER CONTROL ASSEMBLY
1996 TERCEL (RM440U)
REMOVAL
1. REMOVE GLOVE COMPARTMENT PARTS
(See page BO-45).
2. REMOVE INSTRUMENT LOWER FINISH PANEL
(See page BO-45).
3. REMOVE CENTER CLUSTER FINISH PANEL
(See page BO-45).
4. DISCONNECT A/C CONTROL CABLES
5. REMOVE A/C CONTROL ASSEMBLY
(a) Remove the heater control knobs.
(b) Remove the A/C switch.
(c) Remove the heater control panel.
(d) Remove the 4 screws and A/C control assembly.
Page 1200 of 1202
AC1DO-04
Z16144
Z07777
1
3
4 5 6
- AIR CONDITIONINGHEATER CONTROL ASSEMBLY
AC-71
1996 TERCEL (RM440U)
INSPECTION
1. INSPECT BLOWER SWITCH CONTINUTY
Position / CircuitTester connectionSpecified condition
OFF-No continuity
LO5 - 6Continuity
M11 - 5 - 6Continuity
M22 - 5 - 8Continuity
HI5 - 6 - 8Continuity
Illumination circuit3 - 4Continuity
If continuity is not as specified, replace the A/C control assem-
bly.
2. INSPECT A/C SWITCH CONTINUITY
Condition/ CircuitTester connectionSpecified condition
OFF-No continuity
ON4 - 5
4 - 6Continuity
Illumination circuit1 - 3Continuity
Switch continuity:
If continuity is not as specified, replace the switch.
Illumination circuit:
If continuity is not as specified, test the bulb.
Page 1201 of 1202
AC2XH-02
AC-72
- AIR CONDITIONINGHEATER CONTROL ASSEMBLY
1996 TERCEL (RM440U)
ADJUSTMENT
1. ADJUST AIR INLET DAMPER CONTROL CABLE
Set the air inlet damper on ºRECIRCº position, install the control
control cable and lock clamp.
2. ADJUST MODE DAMPER CONTROL CABLE
Set the air inlet damper on ºFACEº position, install the control
cable and lock the clamp.
3. ADJUST AIR MIX DAMPER CONTROL CABLE
Set the air mix damper on ºCOOLº position, install the control
cable and lock the clamp.
Page 1202 of 1202
AC2XG-01
- AIR CONDITIONINGHEATER CONTROL ASSEMBLY
AC-73
1996 TERCEL (RM440U)
INSTALLATION
Installation is in the reverse order of removal procedure (See page AC-70).