Page 53 of 1399

N13795
Quick Disconnect
AdapterCharging
Service Valve Hose
AC2QE−01
N13794
Vacuum Pump
Vacuum Pump Adapter
N13791
Low Pressure
Service Valve
Vacuum Pump Adapter
High Pressure
Service Valve Manifold
Gauge
Set
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
AC−11
1996 LAND CRUISER (RM451U)
EVACUATING
1. CONNECT QUICK DISCONNECT ADAPTERS TO
CHARGING HOSES
2. REMOVE CAPS FROM SERVICE VALVES ON RE- FRIGERANT LINES
3. INSTALL MANIFOLD GAUGE SET
(a) Close both hand valves of manifold gauge set.
(b) Connect the quick disconnect adapters to the service valves.
4. EVACUATE AIR FROM REFRIGERATION SYSTEM
(a) Connect the vacuum pump adapter to the vacuum pump.
(b) Connect the center hose of the manifold gauge set to the vacuum pump adapter.
(c) Open both the high and low hand valves and run the vacu-
um pump.
(d) After 10 minutes or more, check that the low pressure
gauge indicates 750 mmHg (30 in.Hg) or more.
HINT:
If the reading is not 750 mmHg (30 in.Hg) or more, close both
hand valves of manifold gauge set and stop the vacuum pump.
Check the system for leaks and repair as necessary.
(e) Close both the high and low hand valves and stop the vac-
uum pump.
(f) Leave the system in this condition for 5 minutes or more and check that there is no gauge indicator.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 54 of 1399

AC2QF−01
N13790
Low Pressure
Service ValveHigh Pressure
Service Valve
N13792
Gas Leak Detector
AC−12
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
1996 LAND CRUISER (RM451U)
CHARGING
1. INSTALL CHARGING CYLINDER
HINT:
When handling the charging cylinder, always follow the direc-
tion given in the instruction manual.
(a) Charge the proper amount of refrigerant in charging cylin-
der.
(b) Connect the center hose to the charging cylinder.
CAUTION:
Do not open both high and low hand valves of manifold
gauge set.
(c) Open the valve of charging cylinder.
(d) Press the valve core on the side of manifold gauge and expel the air inside of the center hose.
2. INSPECT REFRIGERATION SYSTEM FOR LEAKS
(a) Open the high pressure hand valve and charge refriger- ant.
(b) When the low pressure gauge indicates 98 kPa (1 kgf/cm
2, 14 psi), close the high pressure hand valve.
(c) Using leak detector, check the system for leakage.
(d) If leak is found, repair the faulty component or connection. Add evacuate air from refrigeration system (Refer to 4).
CAUTION:
Use the refrigerant recovery/ recycling machine to recover
the refrigerant whenever replacing parts.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 56 of 1399
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
AC−13
1996 LAND CRUISER (RM451U)
3. CHARGE REFRIGERANT INTO REFRIGERANT SYS-
TEM
If there is no leak after refrigerant leak check charge, the proper
amount of refrigerant into refrigeration system.
CAUTION:
Never run the engine when charging the system through
the high pressure side.Do not open the low pressure hand
valve when the system is being charged with liquid refrig-
erant.
(a) Open the high pressure hand valve fully.
(b) Charge specified amount of refrigerant, then close the high pressure hand valve.
HINT:
A fully charged system is indicated by the sight glass being free
of any bubbles.
4. REMOVE MANIFOLD GAUGE SET
(a) Close both hand valves of manifold gauge set.
(b) Disconnect the quick disconnect adapters from the ser- vice valves.
5. INSTALL CAPS TO SERVICE VALVES ON REFRIGER-
ANT LINES
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 57 of 1399
AC2QB−01
Z04523
AC−14
−
AIR CONDITIONING AIR CONDITIONING SYSTEM
1996 LAND CRUISER (RM451U)
POSITIONING
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 58 of 1399
CH0086
CorrectWrong
AC2QG−01
N01881
DENSOBorroughs
−
AIR CONDITIONING DRIVE BELT
AC−15
1342
Author: Date:
1996 LAND CRUISER (RM451U)
DRIVE BELT
ON−VEHICLE INSPECTION
1. INSPECT DRIVE BELT’S INSTALLATION CONDITION
Check that drive belt fits properly in the ribbed groves.
2. INSPECT DRIVE BELT TENSION
Using a belt tension gauge, check the drive belt tension.
Belt tension gauge:
DENSO BTG −20 (95506−00020) or
Borroughs No. BT −33−73F
Drive belt tension:
New belt 100−150 lbf
Used belt 60−100 lbf
HINT:
”New belt” refers to a belt which has been used less than
5 minutes on a running engine.
”Used belt” refers to a belt which has been on a running
engine for 5 minutes or more.
After installing the drive belt, check that it fits properly in
the ribbed grooves.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 59 of 1399
AC2QH−01
N16451
AC−16
−
AIR CONDITIONING DRIVE BELT
1996 LAND CRUISER (RM451U)
REMOVAL
1. LOOSEN IDLE PULLEY LOCK NUT Torque: 39 N·m (400 kgf·cm, 29 ft·lbf)
2. REMOVE COMPRESSOR DRIVE BELT
Loosen the adjusting bolt and remove the drive belt.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 60 of 1399
AC2QI−01
−
AIR CONDITIONING DRIVE BELT
AC−17
1996 LAND CRUISER (RM451U)
INSTALLATION
Installation is in the reverse order of removal (See page AC−16 ).
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010
Page 61 of 1399
N14326
Low Pressure
Charging Hose
High
Pressure
Charging
Hose
AC2QJ−01
N04392
Sleeve
AC−18
−
AIR CONDITIONING MANIFOLD GAUGE SET
1345
Author: Date:
1996 LAND CRUISER (RM451U)
MANIFOLD GAUGE SET
SET ON
1. CONNECT CHARGING HOSES TO MANIFOLD
GAUGE SET
Tighten the nuts by hand.
CAUTION:
Do not connect the wrong hoses.
2. CONNECT QUICK DISCONNECT ADAPTERS TO CHARGING HOSES
Tighten the nuts by hand.
3. CLOSE BOTH HAND VALVES OF MANIFOLD GAUGE
SET
4. REMOVE CAPS FROM SERVICE VALVES ON RE- FRIGERANT LINE
5. CONNECT QUICK DISCONNECT ADAPTERS TO SER-
VICE VALVES
HINT:
Push the quick disconnect adapter onto the service valve, then
slide the sleeve of the quick disconnect adapter downward to
lock it.
Brought to you by BirfMark
Brought to you by BirfMark
Version 1.11 - 03/16/2010