Page 4 of 63
24-79
      
Notes:  
     
For the defined troubleshooting procedure, it is 
possible, to switch oxygen sensor control off by 
selecting display group 099 under "basic 
setting" and switch it on again under "read 
measuring value block". 
     After selecting display group 099 (either in 
"basic setting" or "read measuring value 
block"), it is possible to switch back and forth 
between "basic setting" (function 04) and "read 
measuring value block" (function 08) by 
pressing buttons 4 or 8 on the VAG1551. 
     Once function 04 "basic setting" is exited, 
oxygen sensor control is automatically switched 
on again. 
     
Test requirements:  
     Road test performed and DTC memory 
erased. 
     Coolant temperature at least 80  C   
Display group 4, display field 3 
Pa
ge 4 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
     
        
        Page 5 of 63
24-80
      
Function test  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select the control module for engine 
electronics using "address word" 01   Page 01
-
9 . 
     
   Engine must run at idle for this.Rapid data transfer  
HELP
Select function XX
    
When indicated on display:  
Note:  
During basic setting, the Evaporative Emission (EVAP) canister purge 
regulator valve (EVAP valve -N80-) is closed and the A/C compressor is 
switched off  -  Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- 
button to confirm input. 
Basic Settin
g 
Q
Input displa
y group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -0- to select "display group number 030" and 
press -Q- button to confirm input. 
System in Basic Setting 30  
1 
2 
3 
4
    
When indicated on display:  
Note:   -  Check oxygen sensor status in display fields 1 and 3.
Pa
ge 5 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
     
        
        Page 9 of 63
24-83
      
Checking oxygen sensor adaptation values 
and control  
     
- Press -C- button.Basic Setting 
Q
Input displa
y group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -3- to select "display group number 033" and 
press -Q- button to confirm input. 
System in Basic Setting 33  
1 
2 
3 
4
    
When indicated on display:  
-  Check oxygen sensor control in display fields 1 and 3.
Pa
ge 9 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
     
        
        Page 12 of 63

24-86
      
- Press -C- button. 
     
-  Press buttons -0-, -3- and -2- to select "display 
group number 032" and press -Q- button to 
confirm input. System in Basic Setting 32  
1 
2 
3 
4
    
When indicated on display:  
-  Check oxygen sensor control in display fields 1 to 4:
  
Display fields  
  
1   2   3   4  
Display group 032: Oxygen sensor adaptation values before catalytic converter  
Display  
xx.x %  
xx.x %  
xx.x %  
xx.x %  
Indicated  
Oxygen sensor 
adaptation value 
Bank 1 at idle  
(additive)  Oxygen sensor adaptation 
value bank 1 at partial 
throttle 
(multiple)  Oxygen sensor 
adaptation value 
Bank 2 at idle  
(additive)  Oxygen sensor adaptation 
value bank 2 at partial 
throttle 
(multiple)  
Functional 
range  -25.0 to 25.0 %  
-25.0 to 25.0 %  
-25.0 to 25.0 %  
  -25.0 to 25.0 %  
  
Specified 
value  -10.0 to 10.0 %  
can fluctuate 
slightly  -10.0 to 10.0 %  
can fluctuate slightly  -10.0 to 10.0 %  
can fluctuate 
slightly  -10.0 to 10.0 %  
can fluctuate slightly  
Notes  
If specified value is not obtained   Page 24
-87
   
Pa
ge 12 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
     
        
        Page 21 of 63
24-94
      
Test sequence  
     
-  Connect VAS5051 tester or VAG1551 scan tool 
and select the control module for engine 
electronics using "address word" 01   Page 01
-
9 . 
     
   Engine must run at idle for this.Rapid data transfer  
HELP
Select function XX
    
When indicated on display:  
-  Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- 
button to confirm input. 
Basic Settin
g 
Q
Input display group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -4- to select "display group number 034" and 
press -Q- button to confirm input. 
System in Basic Setting 34  
1 
2 
3 
4
    
When indicated on display:  
Note:  
This process can take a few minutes.  -  Use VAG1788/10 RPM adjuster to adjust engine speed to between 
1000 and 2400 RPM. 
-  Check specified value in display field 4 after indication "Test ON" 
appears: 
Pa
ge 21 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
     
        
        Page 24 of 63

24-96
      
-  Press buttons -0-, -3- and -5- to select "display 
group number 035" and press -Q- button to 
confirm input. System in Basic Setting 35  
1 
2 
3 
4
    
When indicated on display:  
Note:  
The test in display group 035 is activated simultaneously with the test in 
display group 034 Therefore the test result is indicated immediately after 
display group 035 is selected.  -  Check specified value in display field 4.
  
Display fields  
  
1   2   3   4  
Display group 035: Oxygen sensor aging diagnostic, oxygen sensor before catalytic converter (bank 2)  
Display  xxxx/min  
xxx C  
x.x s  
---  
Indicated  Engine speed 
(RPM)  Exhaust 
temperature  Period duration  
Oxygen sensor before  
Catalytic converter  Diagnostic condition  
Functional 
range  630 to 6800  
70 to 850 C  
0 to 3.0 s  
B1-S2 OK  
B1-S2 not OK  
Specified 
value  1000 to 2400 
RPM  above 380  C  0.1 to 1.8 s  B1-S2 OK  
Notes  
  
  
If the specified value is not reached, replace oxygen sensor 2 
Pa
ge 24 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
     
        
        Page 28 of 63
24-99
 
Rapid data transfer  
HELP
Select function XX
    
When indicated on display:  
Note:  
During basic setting, the Evaporative Emission (EVAP) canister purge 
regulator valve (EVAP valve -N80-) is closed and the A/C compressor is 
switched off  -  Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- 
button to confirm input. 
Basic Settin
g 
Q
Input displa
y group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -4- to select "display group number 034" and 
press -Q- button to confirm input. 
System in Basic Setting 34  
1 
2 
3 
4
    
When indicated on display:  
Note:  
This process can take a few minutes.  -  Use VAG1788/10 RPM adjuster to adjust engine speed to between 
2800 and 3200 RPM. 
-  Continue test as soon as display field 2 indicates an exhaust 
temperature of more than 380  C 
Pa
ge 28 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3 
     
        
        Page 29 of 63
24-100
      
- Press -C- button.
     
-  Let engine continue to idle Basic Setting 
Q
Input displa
y group number XXX
    
When indicated on display:  
-  Press buttons -0-, -3- and -0- to select "display group number 030" and 
press -Q- button to confirm input. 
System in Basic Setting 30  
1 
2 
3 
4 
    
When indicated on display:  
Note:  
"Oxygen sensor status" indicates status of oxygen sensor control and 
oxygen sensors.  -  Check oxygen sensor status for oxygen sensor behind catalytic 
converter in display fields 2 and 4. 
Pa
ge 29 of 63 Ox
yg
en sensor control, checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.3