Page 29 of 61
24-105
 Significance of 3 digit indication in Display Group 030  1  
1  
1  
Display fields 1 to 4  
      X   Oxygen sensor control  
0= inactive  
1= active  
   X      Operational readiness of oxygen sensor  
0= inactive  
1= active  
X         Condition of oxygen sensor heater   
0= inactive  
1= active  
     
- Press -C- button.Basic Setting 
Q
Input displa
y group number XXX
    
When indicated on display  
Test requirements   -  Press buttons -0-, -4- and -3- to select "display group number 043" and press -Q-
button to confirm input. 
Engine runs at 1900 - 2200 RPM 
Pa
ge 29 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 32 of 61
     
-  Press buttons -0-, -4- and -4- to select "display 
group number 044" and press -Q- button to 
confirm input. 
Pa
ge 32 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 34 of 61
24-108
      
Checking oxygen sensor control behind 
catalytic converter  
     
-  Carry out road test for approx.: 10 minutes.Basic Setting 
Q
Input displa
y group number XXX
    
Indicated on display  
-  Press buttons -0-, -3- and -7- to select "display group number 037" and 
press -Q- button to confirm input. 
System in Basic Setting 37  
1 
2 
3 
4
    
Indicated on display  
-  Check oxygen sensor voltage in display field 2.
-  Check dwell time (hold up) between oxygen sensor 1 before catalytic 
converter and oxygen sensor 2 behind catalytic converter in display 
field 3 and diagnostic result in display field 4. 
Pa
ge 34 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 37 of 61
24-110
      
- Press -C- button.
     
-  Press buttons -0-, -3- and -8- to select "display 
group number 038" and press -Q- button to 
confirm input. System in Basic Setting 38  
1 
2 
3 
4
    
Indicated on display: (1 - 4   display fields)  
Pa
ge 37 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 42 of 61
24-114
      
Oxygen sensor heater for oxygen 
sensor, checking
 
     
Note:  
     The oxygen sensor heating circuit is monitored 
by the On Board Diagnostic (OBD). Check DTC 
memory  Page 01-15
 . 
     
-  Connect vehicle diagnostic, testing and 
information system VAS5051 or VAG1551 scan 
tool and select engine electronics control 
module by entering address word "01"   Page 
01
-9 . When doing this the engine must be at 
idle. 
Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press buttons -0- and -8- to select function "Read Measuring Value 
Block" and confirm entry with -Q- button. 
Read Measurin
g Value Block 
Input display group number XXX
    
Indicated on display  
-  Press buttons -0-, -4- and -1- to select "display group number 041" and 
confirm entry with -Q- button. 
Read Measuring Value Block 41  
1 
2 
3 
4
    
Indicated on display  
Pa
ge 42 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2 
     
        
        Page 43 of 61
24-115
      
-  Adjust engine speed to approx: 3000 RPM
     
-  Check resistance of oxygen sensor heater.
  
Display fields  
  
1   2   3   4  
Display Group 041: Oxygen sensor heater, Bank 1 (at idle speed)  
Display  
xxx kOhm  
Htg.bC.ON  
xxx kOhm  
Htg.aC.ON  
Indicates  
Bank 1, Sensor 1  
Status of 
heater  Bank 1, Sensor 2  
Status of 
heater  
Range    
  Htg.bC.ON  
Htg.bC.OFF    
Htg.aC.ON  
Htg.aC.OFF  
Specified 
value  0 - 0.5 kOhm  
Htg.bC.ON/OFF  
0 - 0.5 kOhm  
Htg.aC.ON/OFF  
Note  
It can take a few minutes until 
specification are obtained    
It can take a few minutes until 
specified values are obtained         
- Press -C- button.
     
-  Press buttons -0-, -4- and -2- to select "display 
group number 042" and confirm entry with -Q- 
button. 
Pa
ge 43 of 61 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.24.2