Checking fuel injector delivery quantity  
     
CAUTION! 
     
Fire hazard! Do not smoke, work near heaters 
or open flame, or have anything in the area 
that could ignite fuel. 
    
-  Insert fuel injector to be tested into calibrated measuring container from 
1602 fuel analyzer kit. 
    
-  Connect one terminal of each fuel injector being tested to engine 
Ground (GND) using jumper wire from connector test kit VW 1594. 
-  Connect remaining fuel injector terminal to B+ using remote control 
VAG 1348/3A, adapter wire VAG 1248/3-2 and jumper wire from 
connector test kit VW 1594. 
-  Use scan tool "Output Diagnostic Test Mode" function 03 to trigger fuel 
pump relay -J17-   Repair Group 01. -  Operate remote control VAG 1348/3A for 30 seconds.
Pa
ge 3 of 5 Fuel in
jector leak testin
g and deliver
y quantit
y, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.7 
24-36
      
CAUTION! 
     
Fire Hazard. Do NOT smoke or have anything 
in area that can ignite fuel. 
     
-  After each 30 second fuel injector fill, place 
measuring container on level surface (to 
facilitate accurate reading) and record fuel 
quantity delivered. 
     
   Specified value (each fuel injector): 85-110 ml 
(2.9-3.7 oz.) 
      If the measured quantity for one or more fuel 
injectors is under or over the specified value:  
     
-  Replace faulty fuel injector(s).
      If the measured values for all of the fuel injectors 
(as a set) are under or over the specified values:  
     
- Check system pressure   page 24
-20
 .
     
-  Re-install fuel injectors in reverse order of 
removal. 
     