1995 AUDI A6 AEB Engine Readiness Codes

Page 9 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-66
 
  
Display fields  
  
1   2   3   4  
Display group 60: Adaptation of throttle valve control module to Engine Control Module (ECM)  
Display  
xxx   
xxx   
Idle  
Part throt.  
Full throt.

Page 10 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-67
      
Step 4:  
     
-  Start engine and let run at idle.
Pa
ge 10 of 22 Readiness code11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2

Page 11 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-68
      
Step 5: Oxygen Sensor (O2S) control 
operating condition Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press buttons -0- and -8- to select "Read Measuring Va

Page 12 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-69
 
  
Display fields  
  
1   2   3   4  
Display group 30: Oxygen Sensor (O2S) control operating condition  
Display   xxx   xxx        
Indicated   Status of Heated Oxygen Sensor (HO2S), bank 1

Page 13 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-70
      
Explanation of 3-digit value in display fields 1 
and 2  
     
When display = 1  
1  
2  
3  
  
      1   Oxygen Sensor (O2S) control active  
   1      Heated Oxygen Sensor (HO2S) 
ope

Page 14 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-71
      
Step 6: Oxygen sensor aging (time period) 
     
-  Press -4- button to select "Basic Setting" 
function 04. 
     
-  Press -3- button four times to advance to display 
group number 34.

Page 15 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-72
 
  
Display fields  
  
1   2   3   4  
Display group 34: Oxygen sensor aging (time period of oxygen sensor)  
Display   xxxx RPM   xx.xx ms   xx.xx s   Test OFF/Test ON  
B1-S1 OK/B1-S1 n. 
OK

Page 16 of 22

AUDI A6 1995 C5 / 2.G AEB Engine Readiness Codes 01-73
      
Step 7: Three Way Catalytic Converter (TWC) 
diagnosis Initiate basic setting 
HELP
Input display group number XXX
    
Indicated on display  
-  Press buttons -0-, -4- and -6- to input d
Page:   < prev 1-8 9-16 17-24 next >