01-65
 Test table: display group 2  Read measuring value block  
2   
 Indicated on display  
0 or 1  
  0 or 1  
  
0 or 1  
  0 or 1  
    
     
  
ABS solenoid valve relay:  
For vehicles with Front Wheel Drive (FWD), the display shifts one field toward 
left.  
0   not permitted during "Read measuring value block", the relay was not 
activated during "ignition on". 
- Carry out "Electrical test", step 11   page 01
-68
 .
1   specified value, relay was activated by ABS control module -J104- during 
ignition on. 
     
Voltage at motor for ABS return flow pump:  
For vehicles with Front Wheel Drive (FWD), the display shifts one field toward left.  
 
0   specified value, there is no voltage at the motor for the ABS return flow pump. 1   not permitted during "Read measuring value block", there is voltage at the motor for the 
ABS return flow pump. 
- Carry out "Electrical test", step 12   page 01
-68
 . 
  
Brake light switch: Additional signal only for 
All Wheel Drive (AWD):    
Pa
ge 6 of 79 Read Measurin
g Value Block 
(function 08
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.SU02.01.8