Read Measuring Value Block
(function 08)
Test requirements:
Coolant Temperature at least 80 C.
Electrical consumers switched off (radiator
fan must NOT run during test).
A/C switched off.
Test sequence
- Connect VAS5051 tester Page 01
-7 and
select vehicle system "01 - Engine electronics".
Ignition must remain switched on for this.
or, depending on desired operation:
- Start engine.
Display on VAS5051:
- Select diagnostic function "08 - read measured value block" in
selection -1-.
Pa
ge 1 of 3 Read Measurin
g Value Block
(function 08
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.01.6
Page 2 of 3
01-75
Display on VAS5051:
Note:
Which display group should be chosen depends on current function and
component tests. 1 - Enter display group Max. input value = 255
- Enter desired 3-digit display group number in button field -2- and press
-Q- button to confirm input.
Indicated on VAS5051 for display group 000:
1 - Display group 0
2 - Display field 1 2 3 4 5 6 7 8 9 10
Pa
ge 2 of 3 Read Measurin
g Value Block
(function 08
)
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.01.6
Page 3 of 3
01-76
Indicated on VAS5051 for display group 001 to 255:
Notes: 1 - Display group X
2 - Display field 1
Display field 2
Display field 3
Display field 4
If no display follows, a display field is not assigned.To switch to a different display group, proceed as follows:
Display group
VAS5051 tester
higher
Press button.
Lower
Press button. -
Press "08 - erase DTC memory" to end function button.