1995 AUDI A4 AWM Engine Oxygen Sensor Control Checking Workshop Manual

Page 25 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-93
      
-  Switch ignition off.
      If there is no voltage:  
     
-  Connect VAG1598/31 test box at wiring harness 
to Engine Control Module (ECM), do not connect 
ECM  Page 24
-19
 .

Page 26 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-94
      
Heated Oxygen Sensor (HO2S) and 
oxygen sensor control after Three Way 
Catalytic Converter (TWC), checking
 
     
Note:  
     The oxygen sensor before catalytic converter 
(bank 1, sen

Page 27 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-95
 
  
Special Tools and Equipment  
 
VAG1526A
 VAG1594A
 VAG1598/31
 VAG1788/10 RPM adjuster
 VAS5051 with VAG5051/1
Pa
ge 27 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.

Page 28 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-96
      
Test requirements:  
     
Exhaust system free of leaks. 
     Coolant Temperature at least 80  C. 
     
Test sequence  
     
- Connect VAS5051 tester   Page 01
-7 and 
select vehicle s

Page 29 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-97
 
    
Display on VAS5051:  
1 - Enter display group Max. input value = 255
-  Select function "030" in button field -2- for "display group number 030" 
and press Q button to confirm input.

Page 30 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-98
 
  
Display fields  
  
1   2   3   4  
Display group 030: Oxygen sensor status  
Display   X X X  
X X X  
    
Indicated   Oxygen sensor status, bank 1, sensor 1  
Oxygen sensor status bank 2

Page 31 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-99
 
    
Display on VAS5051:  
Checking oxygen sensor control after catalytic converter  
Test requirement:  -  Do not continue test until indication in display field -2- has reached 
"110" at lea

Page 32 of 46

AUDI A4 1995 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual 24-100
 
    
Display on VAS5051:  
-  Check oxygen sensor voltage in display field -2-.
-  Check oxygen sensor correction value in display field -3- and 
diagnostic result in display field -4-. 
Pa
g