21-11
      
Note:  
     
Hose connections must be completely airtight, 
otherwise measurements will not be correct. 
     Ensure that measuring hose is not pinched at 
hood or side window. 
     Pressing memory key M on turbocharger tester 
will store the last measured value until memory 
key M is pressed again or tester is switched off. 
     The decimal point in the display flashes to 
indicate that the value is being stored. 
     If the battery voltage of the turbocharger tester 
drops below the minimum level, an arrow will 
appear at the top left of the display. 
     Before checking, drive vehicle quickly for at 
least 3 km (choose a safe route that does not 
include stopping). 
     A second mechanic is required to note readings 
with the vehicle moving. 
Pa
ge 12 of 17 Char
ge air s
ystem with turbochar
ger, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE06.21.1