Page 2309 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual VACUUM CIRCUITSÐHEATER OR HEATER A/C CONTROL
Ä HEATING AND AIR CONDITIONING 24 - 5

Page 2310 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual HEATER AND A/C PERFORMANCE TESTS 
HEATER OUTPUT TEST
PRE-DIAGNOSTIC PREPARATIONS
Review Safety Precautions and Warnings before 
performing the following procedures. Check the radiator coolant level, d

Page 2311 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual (5) Insert a thermometer in the left center A/C 
outlet and operate the engine for five minutes. The
A/C clutch may cycle depending on ambient condi-
tions. (6) With the A/C clutch engaged, compare th

Page 2312 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual REFRIGERANT SERVICE PROCEDURES INDEX
page page 
Adding Partial Refrigerant Charge  ............ 10 
Charging Refrigerant SystemÐEmpty System . . . 11
Discharging Refrigerant System  .............. 11

Page 2313 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual REFRIGERANT RECYCLING
(R-12) refrigerant is a chlorofluorocarbon (CFC) 
that can contribute to the depletion of the ozone
layer in the upper atmosphere. To help protect the
ozone layer, an R-12 recycl

Page 2314 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual backed off, immediately point the end of hose toward 
floor, as possibly trapped refrigerant in the hose will
be released.(e) Install service port cap. 
DISCHARGE (HIGH PRESSURE) GAUGE CONNECTION  (1)

Page 2315 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual (1) Attach manifold gauge set. 
(2) Open the windows of the passenger compart-
ment and set the air conditioning controls to A/C,
RECIRC, and Low blower speed. (3) Start the engine and allow it to war

Page 2316 of 2438

CHEVROLET PLYMOUTH ACCLAIM 1993  Service Manual WARNING: REVIEW SAFETY PRECAUTIONS AND 
WARNINGS BEFORE CHARGING THE REFRIGER-
ANT SYSTEM. 
After the system has been tested for leaks and 
evacuated, a refrigerant charge can be injected into
the sys